CAD CAM EDM DRO - Yahoo Group Archive

RE: [CAD_CAM_EDM_DRO] Oiler metering units...

Posted by Tim Goldstein
on 2002-09-17 22:04:30 UTC
Lee,

I tried everything I could think of with the plugged meters on my
grinder. Put them in an ultasonic for about 4 hours. The surfaces got
nice and clean, but the internals of the meter were still clogged solid.
I also tried picking at it and soaking in acetone. I think replacement
is the only way to go.

I don't think I would just replace them all unless you are sure they are
all plugged. With the filter in the oiler it seems remote that they are
all bad. On my grinder they do not have a filter in the oiler and they
got lots of grit in the tank.

Tim
[Denver, CO]

> Hi,
> Is it nuts to replace all the oiler
> metering units on a 25 year old
> milling machine. There are 19 units
> total , or can they be reconditioned
> maybe in an ultrasonic cleaner.
> I found one totally clogged that
> started me off wondering. I ordered
> a TRICO brand replacements. Just
> thought I'd get a consensus.
> Thanks,
> Lee
>

Discussion Thread

Lee Studley 2002-09-17 16:16:09 UTC Oiler metering units... Tim Goldstein 2002-09-17 22:04:30 UTC RE: [CAD_CAM_EDM_DRO] Oiler metering units... Lee Studley 2002-09-18 11:02:11 UTC Re: Oiler metering units... turbulatordude 2002-09-18 13:15:30 UTC Re: Oiler metering units... Lee Studley 2002-09-18 13:41:44 UTC Re: Oiler metering units... turbulatordude 2002-09-18 17:45:53 UTC Re: Oiler metering units... galt1x 2002-09-18 20:26:30 UTC Re: [CAD_CAM_EDM_DRO] Re: Oiler metering units...