RE: [CAD_CAM_EDM_DRO] Re: Gecko Fault/Reset Manager
    Posted by
    
      JJ
    
  
  
    on 2002-09-27 05:18:37 UTC
  
  Just use a 7401 or 7438, it's a quad nand with open collector output.
Regards,
JJ
Be Kind, Be Careful, Be Yourself
sister site to the CCED group, as many of the same members are there,
for OT subjects, that are not allowed on the CCED list.
NOTICE: ALL POSTINGS TO THIS GROUP BECOME PUBLIC DOMAIN BY POSTING THEM.
DON'T POST IF YOU CAN NOT ACCEPT THIS.....NO EXCEPTIONS........
Post messages: CAD_CAM_EDM_DRO@yahoogroups.com
Subscribe: CAD_CAM_EDM_DRO-subscribe@yahoogroups.com
Unsubscribe: CAD_CAM_EDM_DRO-unsubscribe@yahoogroups.com
List owner: CAD_CAM_EDM_DRO-owner@yahoogroups.com, wanliker@...
Moderator: jmelson@... timg@... [Moderator]
URL to this group: http://groups.yahoo.com/group/CAD_CAM_EDM_DRO
bill,
List Mom
List Owner
 
Your use of Yahoo! Groups is subject to
http://docs.yahoo.com/info/terms/
Regards,
JJ
Be Kind, Be Careful, Be Yourself
> -----Original Message-----http://groups.yahoo.com/group/jobshophomeshop I consider this as a
> From: Matt Shaver [mailto:mshaver@...]
> Sent: Thursday, September 26, 2002 6:21 PM
> To: CAD_CAM_EDM_DRO@yahoogroups.com
> Subject: Re: [CAD_CAM_EDM_DRO] Re: Gecko Fault/Reset Manager
>
>
> On Thursday 26 September 2002 03:52 pm, you wrote:
> > Just didn't know if I could parallel the gates
> > output.
>
> You can't wire-OR together the outputs of the 7400, you need
> to connect each
> NAND gate output (that you're using) to the input of a 7407 Hex Open
> Collector Buffer. The outputs of the 7407 can be connected
> together, and that
> signal needs to be pulled up to +5Vdc through a 1k-10k resistor:
>
> Obligatory ASCII Schematic (view in fixed width font):
>
> Xidx -\
> =|)o--|>-+-/\/\/\/-O 5V
> Xhsw -/ |
> |
> Yidx -\ |
> =|)o--|>-+
> Yhsw -/ |
> |
> Zidx -\ |
> =|)o--|>-+
> Zhsw -/ |
> |
> O To Home Input
>
> =|)o- 7400 NAND Gate
> -|>- 7407 Open Collector Buffer
>
> Good Luck,
> Matt
>
> Addresses:
> FAQ: http://www.ktmarketing.com/faq.html
> FILES: http://groups.yahoo.com/group/CAD_CAM_EDM_DRO/files/
>
> OFF Topic POSTS: General Machining
> If you wish to post on unlimited OT subjects goto:
> aol://5863:126/rec.crafts.metalworking or go thru Google.com
> to reach it if you have trouble.
> http://www.metalworking.com/news_servers.html
>
sister site to the CCED group, as many of the same members are there,
for OT subjects, that are not allowed on the CCED list.
NOTICE: ALL POSTINGS TO THIS GROUP BECOME PUBLIC DOMAIN BY POSTING THEM.
DON'T POST IF YOU CAN NOT ACCEPT THIS.....NO EXCEPTIONS........
Post messages: CAD_CAM_EDM_DRO@yahoogroups.com
Subscribe: CAD_CAM_EDM_DRO-subscribe@yahoogroups.com
Unsubscribe: CAD_CAM_EDM_DRO-unsubscribe@yahoogroups.com
List owner: CAD_CAM_EDM_DRO-owner@yahoogroups.com, wanliker@...
Moderator: jmelson@... timg@... [Moderator]
URL to this group: http://groups.yahoo.com/group/CAD_CAM_EDM_DRO
bill,
List Mom
List Owner
Your use of Yahoo! Groups is subject to
http://docs.yahoo.com/info/terms/
Discussion Thread
  
    dakota8833
  
2002-09-26 06:24:51 UTC
  Gecko Fault/Reset Manager
  
    awallin25
  
2002-09-26 10:56:57 UTC
  Re: Gecko Fault/Reset Manager
  
    dakota8833
  
2002-09-26 12:52:48 UTC
  Re: Gecko Fault/Reset Manager
  
    Matt Shaver
  
2002-09-26 18:18:02 UTC
  Re: [CAD_CAM_EDM_DRO] Re: Gecko Fault/Reset Manager
  
    JJ
  
2002-09-27 05:18:37 UTC
  RE: [CAD_CAM_EDM_DRO] Re: Gecko Fault/Reset Manager
  
    Ray Henry
  
2002-09-27 06:28:45 UTC
  Re: Re: Gecko Fault/Reset Manager
  
    Matt Shaver
  
2002-09-27 11:42:18 UTC
  Re: [CAD_CAM_EDM_DRO] Re: Gecko Fault/Reset Manager
  
    dakota8833
  
2002-10-01 12:06:26 UTC
  Gecko Fault/Reset Manager
  
    vrsculptor
  
2002-10-01 14:21:28 UTC
  Re: Gecko Fault/Reset Manager
  
    dakota8833
  
2002-10-01 16:02:20 UTC
  Re: Gecko Fault/Reset Manager
  
    Frank de Beer
  
2002-10-02 00:27:35 UTC
  RE: [CAD_CAM_EDM_DRO] Re: Gecko Fault/Reset Manager
  
    Frank de Beer
  
2002-10-02 04:48:20 UTC
  encoder 12V --> 5V
  
    Jon Elson
  
2002-10-02 09:25:55 UTC
  Re: [CAD_CAM_EDM_DRO] Re: Gecko Fault/Reset Manager
  
    Erik Reikes
  
2002-10-02 13:30:37 UTC
  Re: encoder 12V --> 5V