RE: [CAD_CAM_EDM_DRO] Re: Gecko Fault/Reset Manager
Posted by
JJ
on 2002-09-27 05:18:37 UTC
Just use a 7401 or 7438, it's a quad nand with open collector output.
Regards,
JJ
Be Kind, Be Careful, Be Yourself
sister site to the CCED group, as many of the same members are there,
for OT subjects, that are not allowed on the CCED list.
NOTICE: ALL POSTINGS TO THIS GROUP BECOME PUBLIC DOMAIN BY POSTING THEM.
DON'T POST IF YOU CAN NOT ACCEPT THIS.....NO EXCEPTIONS........
Post messages: CAD_CAM_EDM_DRO@yahoogroups.com
Subscribe: CAD_CAM_EDM_DRO-subscribe@yahoogroups.com
Unsubscribe: CAD_CAM_EDM_DRO-unsubscribe@yahoogroups.com
List owner: CAD_CAM_EDM_DRO-owner@yahoogroups.com, wanliker@...
Moderator: jmelson@... timg@... [Moderator]
URL to this group: http://groups.yahoo.com/group/CAD_CAM_EDM_DRO
bill,
List Mom
List Owner
Your use of Yahoo! Groups is subject to
http://docs.yahoo.com/info/terms/
Regards,
JJ
Be Kind, Be Careful, Be Yourself
> -----Original Message-----http://groups.yahoo.com/group/jobshophomeshop I consider this as a
> From: Matt Shaver [mailto:mshaver@...]
> Sent: Thursday, September 26, 2002 6:21 PM
> To: CAD_CAM_EDM_DRO@yahoogroups.com
> Subject: Re: [CAD_CAM_EDM_DRO] Re: Gecko Fault/Reset Manager
>
>
> On Thursday 26 September 2002 03:52 pm, you wrote:
> > Just didn't know if I could parallel the gates
> > output.
>
> You can't wire-OR together the outputs of the 7400, you need
> to connect each
> NAND gate output (that you're using) to the input of a 7407 Hex Open
> Collector Buffer. The outputs of the 7407 can be connected
> together, and that
> signal needs to be pulled up to +5Vdc through a 1k-10k resistor:
>
> Obligatory ASCII Schematic (view in fixed width font):
>
> Xidx -\
> =|)o--|>-+-/\/\/\/-O 5V
> Xhsw -/ |
> |
> Yidx -\ |
> =|)o--|>-+
> Yhsw -/ |
> |
> Zidx -\ |
> =|)o--|>-+
> Zhsw -/ |
> |
> O To Home Input
>
> =|)o- 7400 NAND Gate
> -|>- 7407 Open Collector Buffer
>
> Good Luck,
> Matt
>
> Addresses:
> FAQ: http://www.ktmarketing.com/faq.html
> FILES: http://groups.yahoo.com/group/CAD_CAM_EDM_DRO/files/
>
> OFF Topic POSTS: General Machining
> If you wish to post on unlimited OT subjects goto:
> aol://5863:126/rec.crafts.metalworking or go thru Google.com
> to reach it if you have trouble.
> http://www.metalworking.com/news_servers.html
>
sister site to the CCED group, as many of the same members are there,
for OT subjects, that are not allowed on the CCED list.
NOTICE: ALL POSTINGS TO THIS GROUP BECOME PUBLIC DOMAIN BY POSTING THEM.
DON'T POST IF YOU CAN NOT ACCEPT THIS.....NO EXCEPTIONS........
Post messages: CAD_CAM_EDM_DRO@yahoogroups.com
Subscribe: CAD_CAM_EDM_DRO-subscribe@yahoogroups.com
Unsubscribe: CAD_CAM_EDM_DRO-unsubscribe@yahoogroups.com
List owner: CAD_CAM_EDM_DRO-owner@yahoogroups.com, wanliker@...
Moderator: jmelson@... timg@... [Moderator]
URL to this group: http://groups.yahoo.com/group/CAD_CAM_EDM_DRO
bill,
List Mom
List Owner
Your use of Yahoo! Groups is subject to
http://docs.yahoo.com/info/terms/
Discussion Thread
dakota8833
2002-09-26 06:24:51 UTC
Gecko Fault/Reset Manager
awallin25
2002-09-26 10:56:57 UTC
Re: Gecko Fault/Reset Manager
dakota8833
2002-09-26 12:52:48 UTC
Re: Gecko Fault/Reset Manager
Matt Shaver
2002-09-26 18:18:02 UTC
Re: [CAD_CAM_EDM_DRO] Re: Gecko Fault/Reset Manager
JJ
2002-09-27 05:18:37 UTC
RE: [CAD_CAM_EDM_DRO] Re: Gecko Fault/Reset Manager
Ray Henry
2002-09-27 06:28:45 UTC
Re: Re: Gecko Fault/Reset Manager
Matt Shaver
2002-09-27 11:42:18 UTC
Re: [CAD_CAM_EDM_DRO] Re: Gecko Fault/Reset Manager
dakota8833
2002-10-01 12:06:26 UTC
Gecko Fault/Reset Manager
vrsculptor
2002-10-01 14:21:28 UTC
Re: Gecko Fault/Reset Manager
dakota8833
2002-10-01 16:02:20 UTC
Re: Gecko Fault/Reset Manager
Frank de Beer
2002-10-02 00:27:35 UTC
RE: [CAD_CAM_EDM_DRO] Re: Gecko Fault/Reset Manager
Frank de Beer
2002-10-02 04:48:20 UTC
encoder 12V --> 5V
Jon Elson
2002-10-02 09:25:55 UTC
Re: [CAD_CAM_EDM_DRO] Re: Gecko Fault/Reset Manager
Erik Reikes
2002-10-02 13:30:37 UTC
Re: encoder 12V --> 5V