Re: [CAD_CAM_EDM_DRO] Re: Commercial EDM capacitance ranges
Posted by
Larry Edington
on 2003-02-10 19:50:37 UTC
Easco 200 amp EDM supply.
later,
Larry Edington
later,
Larry Edington
----- Original Message -----
From: <davemucha@...>
To: <CAD_CAM_EDM_DRO@yahoogroups.com>
Sent: Monday, February 10, 2003 9:26 PM
Subject: [CAD_CAM_EDM_DRO] Re: Commercial EDM capacitance ranges
> What was the origional use for the power supply ?
>
>
>
> --- In CAD_CAM_EDM_DRO@yahoogroups.com, "Larry Edington"
> <ledington@a...> wrote:
> > I just bought a power supply that's supposed to weigh around 600
> pounds.
> > Just so I can
> > take it apart and learn how it works. Being older technology I
> figure I can
> > replace a lot of the
> > control circuits with a microcontroller or two. Or maybe a single
> TI DSP.
> >
> > thanks,
> > Larry Edington
> >
> > ----- Original Message -----
> > From: "RichD" <cmsteam@s...>
> > To: <CAD_CAM_EDM_DRO@yahoogroups.com>
> > Sent: Monday, February 10, 2003 9:51 AM
> > Subject: Re: [CAD_CAM_EDM_DRO] Commercial EDM capacitance ranges
> >
> >
> > > Larry,
> > > I will try to answer best as I can.
> > > Industrial machines are huge. I have repaired wire and plunge
> units.
> > > The manufacturers **refuse** to supply any internal docs.
> > > Opening one of these up reveals an enormouse array of electronics.
> > > Which capacitor?. There are many. I have never gotten to the
> level of
> > > knowlege (or needed to) to discover the output circuits.
> > > All is computer controlled, in any case.
> > > The water for the flushing thru the cut in the wire EDM is just
> tap water
> > > recirculated and filtered for use as the local water is very
> mineral free.
> > > It splashes about the work area and drains back into the 'dirty'
> tank.
> > > The plunge EDM is another matter and an entirely different
> operation.
> > > This must be submerged to control the intense sparking on
> electrodes
> > having
> > > much larger surface areas than wire (.011" dia). Quenching fire
> and smoke
> > > as well as flushing movements are the usual method. A type of
> orderless
> > oil
> > > is pumped into the well on startup and automatically drained on
> stop.
> > > Even so, a lot of fire is seen to erupt from under an electrode.
> > > An occasional puff will make it to the surface.
> > > RichD
> > >
> > > Larry Edington wrote:
> > > >
> > > > Anybody know the range of capacitance found in a typical
> commercial wire
> > and sinker EDM?
> > > >
> > > > What about the adjustability of the capacitance? How many
> different
> > steps are usually available?
> > > >
> > > > What about voltage? I've read 80 volts max is typical.
> > > >
> > > > I assume if you are doing active spark control, you just put in
> enough
> > capacitance to supply your longest
> > > > spark time and limit down from there. I'm trying to determine
> what those
> > ranges are for spark time and max
> > > > voltages.
> > > >
> > > > One more question ( for now ). Why is deionized water used in
> wire EDM
> > when an oil product is used for sinker EDM?
> > > >
> > > > thanks,
> > > > Larry E.
> > >
> > > Addresses:
> > > FAQ: http://www.ktmarketing.com/faq.html
> > > FILES: http://groups.yahoo.com/group/CAD_CAM_EDM_DRO/files/
> > > Post Messages: CAD_CAM_EDM_DRO@yahoogroups.com
> > >
> > > Subscribe: CAD_CAM_EDM_DRO-subscribe@yahoogroups.com
> > > Unsubscribe: CAD_CAM_EDM_DRO-unsubscribe@yahoogroups.com
> > > List owner: CAD_CAM_EDM_DRO-owner@yahoogroups.com,
> wanliker@a...,
> > timg@k...
> > > Moderator: pentam@c... indigo_red@q... [Moderators]
> > > URL to this group: http://groups.yahoo.com/group/CAD_CAM_EDM_DRO
> > >
> > > OFF Topic POSTS: General Machining
> > > If you wish to post on unlimited OT subjects goto:
> > aol://5863:126/rec.crafts.metalworking or go thru Google.com to
> reach it if
> > you have trouble.
> > > http://www.metalworking.com/news_servers.html
> > >
> > > http://groups.yahoo.com/group/jobshophomeshop I consider this
> to be a
> > sister site to the CCED group, as many of the same members are
> there, for OT
> > subjects, that are not allowed on the CCED list.
> > >
> > > NOTICE: ALL POSTINGS TO THIS GROUP BECOME PUBLIC DOMAIN BY
> POSTING THEM.
> > DON'T POST IF YOU CAN NOT ACCEPT THIS.....NO EXCEPTIONS........
> > > bill
> > > List Mom
> > > List Owner
> > >
> > >
> > >
> > > Your use of Yahoo! Groups is subject to
> http://docs.yahoo.com/info/terms/
> > >
> > >
>
>
> Addresses:
> FAQ: http://www.ktmarketing.com/faq.html
> FILES: http://groups.yahoo.com/group/CAD_CAM_EDM_DRO/files/
> Post Messages: CAD_CAM_EDM_DRO@yahoogroups.com
>
> Subscribe: CAD_CAM_EDM_DRO-subscribe@yahoogroups.com
> Unsubscribe: CAD_CAM_EDM_DRO-unsubscribe@yahoogroups.com
> List owner: CAD_CAM_EDM_DRO-owner@yahoogroups.com, wanliker@...,
timg@...
> Moderator: pentam@... indigo_red@... [Moderators]
> URL to this group: http://groups.yahoo.com/group/CAD_CAM_EDM_DRO
>
> OFF Topic POSTS: General Machining
> If you wish to post on unlimited OT subjects goto:
aol://5863:126/rec.crafts.metalworking or go thru Google.com to reach it if
you have trouble.
> http://www.metalworking.com/news_servers.html
>
> http://groups.yahoo.com/group/jobshophomeshop I consider this to be a
sister site to the CCED group, as many of the same members are there, for OT
subjects, that are not allowed on the CCED list.
>
> NOTICE: ALL POSTINGS TO THIS GROUP BECOME PUBLIC DOMAIN BY POSTING THEM.
DON'T POST IF YOU CAN NOT ACCEPT THIS.....NO EXCEPTIONS........
> bill
> List Mom
> List Owner
>
>
>
> Your use of Yahoo! Groups is subject to http://docs.yahoo.com/info/terms/
>
>
Discussion Thread
Larry Edington
2003-02-09 23:40:53 UTC
Commercial EDM capacitance ranges
Marcus & Eva
2003-02-10 07:42:56 UTC
Re: [CAD_CAM_EDM_DRO] Commercial EDM capacitance ranges
RichD
2003-02-10 07:55:28 UTC
Re: [CAD_CAM_EDM_DRO] Commercial EDM capacitance ranges
turbulatordude <davemucha@j...
2003-02-10 10:05:33 UTC
Re: Commercial EDM capacitance ranges
wanliker@a...
2003-02-10 14:05:50 UTC
Re: [CAD_CAM_EDM_DRO] Re: Commercial EDM capacitance ranges
Larry Edington
2003-02-10 19:13:05 UTC
Re: [CAD_CAM_EDM_DRO] Commercial EDM capacitance ranges
Larry Edington
2003-02-10 19:18:27 UTC
Re: [CAD_CAM_EDM_DRO] Commercial EDM capacitance ranges
Larry Edington
2003-02-10 19:25:00 UTC
Re: [CAD_CAM_EDM_DRO] Re: Commercial EDM capacitance ranges
turbulatordude <davemucha@j...
2003-02-10 19:26:31 UTC
Re: Commercial EDM capacitance ranges
Larry Edington
2003-02-10 19:50:37 UTC
Re: [CAD_CAM_EDM_DRO] Re: Commercial EDM capacitance ranges
Marcus & Eva
2003-02-11 08:23:27 UTC
Re: [CAD_CAM_EDM_DRO] Commercial EDM capacitance ranges