Re: [CAD_CAM_EDM_DRO] panel meters
Posted by
JanRwl@A...
on 2004-03-09 11:28:09 UTC
In a message dated 3/9/2004 11:12:15 AM Central Standard Time,
johnatl@... writes:
Connect the meter
across the 1 000 ohm resistor. The voltage displayed will be 1/1000 the
input, i.e. 200V in will put 200mV across the meter.
As far as current, you'll need a very low resistance, precision
resistor to put in series with your power supply and load. Scaling is
similar to above. E.g. You have a 0-200mV meter, and you want to
monitor 0-20A. So, we know we want 200mV out for 20A current, so:
.200
In what galaxy???
[Non-text portions of this message have been removed]
johnatl@... writes:
Connect the meter
across the 1 000 ohm resistor. The voltage displayed will be 1/1000 the
input, i.e. 200V in will put 200mV across the meter.
As far as current, you'll need a very low resistance, precision
resistor to put in series with your power supply and load. Scaling is
similar to above. E.g. You have a 0-200mV meter, and you want to
monitor 0-20A. So, we know we want 200mV out for 20A current, so:
.200
In what galaxy???
[Non-text portions of this message have been removed]
Discussion Thread
plastiguy
2004-03-09 06:07:01 UTC
panel meters
james_cullins@s...
2004-03-09 07:15:05 UTC
Re: [CAD_CAM_EDM_DRO] panel meters
lathehand_2
2004-03-09 08:22:44 UTC
Re: panel meters
John Johnson
2004-03-09 09:09:06 UTC
Re: [CAD_CAM_EDM_DRO] panel meters
washcomp
2004-03-09 09:28:29 UTC
Re: panel meters
JanRwl@A...
2004-03-09 11:28:09 UTC
Re: [CAD_CAM_EDM_DRO] panel meters
Bob McKnight
2004-03-09 12:52:14 UTC
Re: [CAD_CAM_EDM_DRO] panel meters
John Johnson
2004-03-09 13:12:49 UTC
Re: [CAD_CAM_EDM_DRO] panel meters
wanliker@a...
2004-03-09 15:59:49 UTC
Re: [CAD_CAM_EDM_DRO] panel meters
Harvey White
2004-03-09 20:32:33 UTC
Re: [CAD_CAM_EDM_DRO] panel meters
JanRwl@A...
2004-03-09 22:04:40 UTC
Re: [CAD_CAM_EDM_DRO] panel meters
John Johnson
2004-03-10 03:50:02 UTC
Re: [CAD_CAM_EDM_DRO] panel meters
Greg Nuspel
2004-03-10 03:58:55 UTC
Re: [CAD_CAM_EDM_DRO] panel meters
John Johnson
2004-03-10 04:31:54 UTC
Re: [CAD_CAM_EDM_DRO] panel meters
james_cullins@s...
2004-03-10 05:03:43 UTC
Re: [CAD_CAM_EDM_DRO] panel meters
caudlet
2004-03-10 07:37:39 UTC
Re: panel meters (why?)
JanRwl@A...
2004-03-10 13:35:53 UTC
Re: [CAD_CAM_EDM_DRO] panel meters
caudlet
2004-03-10 15:12:03 UTC
Re: panel meters
wanliker@a...
2004-03-10 16:02:15 UTC
Re: [CAD_CAM_EDM_DRO] Re: panel meters
JanRwl@A...
2004-03-10 20:31:26 UTC
Re: [CAD_CAM_EDM_DRO] Re: panel meters
Bob McKnight
2004-03-11 06:36:13 UTC
Re: [CAD_CAM_EDM_DRO] Re: panel meters
Andy Wander
2004-03-11 06:50:27 UTC
RE: [CAD_CAM_EDM_DRO] Re: panel meters
caudlet
2004-03-11 16:41:23 UTC
Re: panel meters
Bob McKnight
2004-03-12 21:50:37 UTC
RE: [CAD_CAM_EDM_DRO] Re: panel meters
Bob McKnight
2004-03-12 21:55:23 UTC
Re: [CAD_CAM_EDM_DRO] Re: panel meters
Roy J. Tellason
2004-03-13 10:17:16 UTC
Re: [CAD_CAM_EDM_DRO] Re: panel meters