RE: [CAD_CAM_EDM_DRO] Re: Power Supply & Gecko's

Posted by Andy Wander
on 2005-08-13 08:45:50 UTC
Depends on the meter. Most of the better digital meters will measure ONLY AC
or ONLY DC when switched to that setting, in my experience.

You are correct that a meter that simply rectifies and smoothe AC to measure
it will not know if there is some DC also being applied to the rectifier.

Andy Wander
Verrex Corporation

-----Original Message-----
From: Peter Reilley [mailto:micrio@...]
Sent: Saturday, August 13, 2005 11:43 AM
To: CAD_CAM_EDM_DRO@yahoogroups.com
Subject: Re: [CAD_CAM_EDM_DRO] Re: Power Supply & Gecko's


----- Original Message -----
From: "caudlet" <thom@...>
To: <CAD_CAM_EDM_DRO@yahoogroups.com>
Sent: Saturday, August 13, 2005 11:30 AM
Subject: [CAD_CAM_EDM_DRO] Re: Power Supply & Gecko's


> --- In CAD_CAM_EDM_DRO@yahoogroups.com, "smith67au" <thdsmith@b...> wrote:
>> Hi All,
>>
>> This is my first post and I'm hoping I can get some advice.
>>
>> I have a retrofit bidgeport mill runing on steppers with Gecko
>> 201/210's.
>>
>> Current settings are two at 7.0 amps and one at 3.5 amps.
>>
>> I have been driving the mill with a 24V 25 Amp regulated power supply,
>> for a few years.
>>
>> I wanted to upgrade the power supply, so I've built one similar to the
>> "Simple Power Supply" in the files section, using a transformer I had
>> laying about.
>>
>> I have 48VAC out of the transformer going through the bridge rectifier
>> (35A 400V) and then paralleled with a 22,000 uf Cap.
>> Result is I am getting around 70VDC as expected.
>> I am also measuring quite a bit of AC (around 150V), but it might be
>> because my multimeter is a cheap one (the 24 VDC power supply I have
>> been using for a long time also has an AC voltage (30VAC).
>
> It sounds like you meter is maybe picking up the switching noise of
> the chopper circuits and giving you a false reading. WIth no load on
> the power supply you should get pure DC. As you load the supply the
> supply starts to have ripple. It's the difference of the peak voltage
> at the center of the waveform and the amount of current you are
> drawing out of the cap on average. The amount of ripple is expressed
> as a percentage of the voltage. The factors are load current, power
> factor of the load and the value of the capacitor. The bigger the cap
> the lower the ripple. Is ripple bad? Only for the motor drive
> electronics.

I believe that you cannot measure AC ripple with an AC meter where
there is a DC component. The meter does not filter out the DC.
Thus, it get confused. You really need a scope to measure AC ripple.

Pete.



Addresses:
FAQ: http://www.ktmarketing.com/faq.html
FILES: http://groups.yahoo.com/group/CAD_CAM_EDM_DRO/files/
Post Messages: CAD_CAM_EDM_DRO@yahoogroups.com

Subscribe: CAD_CAM_EDM_DRO-subscribe@yahoogroups.com
Unsubscribe: CAD_CAM_EDM_DRO-unsubscribe@yahoogroups.com
List owner: CAD_CAM_EDM_DRO-owner@yahoogroups.com, wanliker@...,
timg@...
Moderator: pentam@... indigo_red@... davemucha@...
[Moderators]
URL to this group: http://groups.yahoo.com/group/CAD_CAM_EDM_DRO

OFF Topic POSTS: General Machining
If you wish to post on unlimited OT subjects goto:
aol://5863:126/rec.crafts.metalworking or go thru Google.com to reach it if
you have trouble.
http://www.metalworking.com/news_servers.html

http://groups.yahoo.com/group/jobshophomeshop I consider this to be a
sister site to the CCED group, as many of the same members are there, for OT
subjects, that are not allowed on the CCED list.

NOTICE: ALL POSTINGS TO THIS GROUP BECOME PUBLIC DOMAIN BY POSTING THEM.
DON'T POST IF YOU CAN NOT ACCEPT THIS.....NO EXCEPTIONS........
bill
List Mom
List Owner


Yahoo! Groups Links

Discussion Thread

smith67au 2005-08-13 05:48:19 UTC Power Supply & Gecko's caudlet 2005-08-13 08:30:33 UTC Re: Power Supply & Gecko's Peter Reilley 2005-08-13 08:43:53 UTC Re: [CAD_CAM_EDM_DRO] Re: Power Supply & Gecko's Andy Wander 2005-08-13 08:45:50 UTC RE: [CAD_CAM_EDM_DRO] Re: Power Supply & Gecko's Roy J. Tellason 2005-08-13 09:03:53 UTC Re: [CAD_CAM_EDM_DRO] Re: Power Supply & Gecko's wanliker@a... 2005-08-13 09:20:52 UTC Re: [CAD_CAM_EDM_DRO] Re: Power Supply & Gecko's turbulatordude 2005-08-13 09:24:39 UTC Re: Power Supply & Gecko's turbulatordude 2005-08-13 09:49:03 UTC Re: Power Supply & Gecko's Stephen Wille Padnos 2005-08-13 10:06:58 UTC Re: [CAD_CAM_EDM_DRO] Re: Power Supply & Gecko's Roy J. Tellason 2005-08-13 10:31:05 UTC Re: [CAD_CAM_EDM_DRO] Re: Power Supply & Gecko's smith67au 2005-08-13 15:14:33 UTC Re: Power Supply & Gecko's Jon Elson 2005-08-13 18:49:05 UTC Re: [CAD_CAM_EDM_DRO] Re: Power Supply & Gecko's smith67au 2005-08-14 05:29:35 UTC Re: Power Supply & Gecko's