Re: [CAD_CAM_EDM_DRO] Re: AC servo motor

Posted by David Speck
on 2006-10-03 21:21:46 UTC
Horace,

Mach 3 outputs step and direction signals, suitable for directly driving
stepper systems. Most older AC servos accept a +/- 10 volt DC analog
control input which sets their direction and speed. A few newer AC
servo amps also accept step and direction signals instead, but I've
never had one of these to play with.

Rutex and Skyco both make step/dir to servo converter boards. I use
Rutex 991H boards to interface step and direction signals from my older
Ah-Ha controller system to the Yaskawa AC servo amps on my CNC lathe.

Dave

Horace, T.L.Ho wrote:
> Hi Randy,
>
> Thanks. I wonder why don't gecko develop low cost drives for AC
> servos. Is it because drives and AC servos are already a combo sold
> by Yaskawa etc.,so there no such chance for gecko to do so.
>
> And one more thing, is Mach 3 compatible with AC servos ? Sorry if I
> had asked silly questions, I am an idiot in electronics.
>
> Horace.
>

Discussion Thread

Horace, T.L.Ho 2006-10-03 04:41:27 UTC AC servo motor skykotech 2006-10-03 09:23:03 UTC Re: AC servo motor cnc002@a... 2006-10-03 09:51:42 UTC Re: [CAD_CAM_EDM_DRO] Re: AC servo motor Horace, T.L.Ho 2006-10-03 20:48:58 UTC Re: AC servo motor Horace, T.L.Ho 2006-10-03 21:06:23 UTC Re: AC servo motor David Speck 2006-10-03 21:21:46 UTC Re: [CAD_CAM_EDM_DRO] Re: AC servo motor Dave Halliday 2006-10-03 22:20:45 UTC RE: [CAD_CAM_EDM_DRO] Re: AC servo motor Paul Kelly 2006-10-04 03:52:53 UTC Glass scale current requirement Paul Kelly 2006-10-04 06:44:12 UTC Modbus control Omron VFD Jon Elson 2006-10-04 09:07:24 UTC Re: [CAD_CAM_EDM_DRO] Glass scale current requirement caudlet 2006-10-04 10:39:59 UTC Re: Modbus control Omron VFD Paul Kelly 2006-10-04 17:50:31 UTC RE: [CAD_CAM_EDM_DRO] Re: Modbus control Omron VFD caudlet 2006-10-06 08:40:54 UTC Re: Modbus control Omron VFD Paul Kelly 2006-10-06 08:50:53 UTC RE: [CAD_CAM_EDM_DRO] Re: Modbus control Omron VFD