CAD CAM EDM DRO - Yahoo Group Archive

Pullup resistor on a NC touch probe, Mach3?

Posted by Monte
on 2008-04-11 11:56:09 UTC
Longtime lurker here. Would a pullup resistor be a good idea on a NC
touch probe? I'm thinking it's just like a limit switch to Mach.
Plus I'm not sure if connecting a NC switch directly to the parallel
port is good. Running Mach3 and the probe is on pin 11. Then, with a
pullup resistor, would it be active low, or high?

Thanks,
Monte

Discussion Thread

Monte 2008-04-11 11:56:09 UTC Pullup resistor on a NC touch probe, Mach3? Ron Ginger 2008-04-12 05:43:22 UTC Re: Pullup resistor on a NC touch probe, Mach3? Monte 2008-04-12 11:32:31 UTC Re: Pullup resistor on a NC touch probe, Mach3? JCullins 2008-04-12 13:47:10 UTC Re: [CAD_CAM_EDM_DRO] Pullup resistor on a NC touch probe, Mach3? Monte 2008-04-12 18:33:40 UTC Re: Pullup resistor on a NC touch probe, Mach3? Arnie Minear 2008-04-17 11:58:18 UTC Re: Pullup resistor on a NC touch probe, Mach3? Monte 2008-04-18 07:44:44 UTC Re: Pullup resistor on a NC touch probe, Mach3? Arnie Minear 2008-04-18 08:05:44 UTC Re: Pullup resistor on a NC touch probe, Mach3? Monte 2008-04-18 14:40:19 UTC Re: Pullup resistor on a NC touch probe, Mach3?