Bryan Mumford wrote:
> The dropped steps only occur in one direction. Does that make sense
> in any way as a clue? It seems odd. The general position is the same.
>
>
Yes, alignment problems with the read head very OFTEN show up ONLY when
moving in
one direction. The wire or strip that moves the head can tilt it as it
applies the force to move the head,
and that can cause it to either lift from the scale, tilt a bit or whatever.

Cable problems can also act like that at first. You can try wiggling
the cable
all along its length. If the display jumps when you wiggle the cable,
it is most likely a bad
cable.

Jon

Discussion Thread

microset3 2011-02-14 13:29:43 UTC Sargon encoder disassembly help Jon Elson 2011-02-14 19:45:21 UTC Re: [CAD_CAM_EDM_DRO] Sargon encoder disassembly help Bryan Mumford 2011-02-14 19:54:02 UTC Re: [CAD_CAM_EDM_DRO] Sargon encoder disassembly help Roland Jollivet 2011-02-14 23:19:06 UTC Re: [CAD_CAM_EDM_DRO] Sargon encoder disassembly help Jon Elson 2011-02-15 19:41:43 UTC Re: [CAD_CAM_EDM_DRO] Sargon encoder disassembly help Jon Elson 2011-02-15 19:43:53 UTC Re: [CAD_CAM_EDM_DRO] Sargon encoder disassembly help Bryan Mumford 2011-02-16 09:25:09 UTC Re: [CAD_CAM_EDM_DRO] Sargon encoder disassembly help Bryan Mumford 2011-02-16 12:28:37 UTC Re: [CAD_CAM_EDM_DRO] Sargon encoder disassembly help Jon Elson 2011-02-16 19:38:39 UTC Re: [CAD_CAM_EDM_DRO] Sargon encoder disassembly help Jon Elson 2011-02-16 19:41:00 UTC Re: [CAD_CAM_EDM_DRO] Sargon encoder disassembly help David G. LeVine 2011-02-22 13:51:28 UTC Re: [CAD_CAM_EDM_DRO] Sargon encoder disassembly help