Re: distance from controller to stepper
Posted by
Mariss Freimanis
on 2000-10-17 10:29:28 UTC
The longest motor cable run application I've encountered was 1,000
feet for use in a nuclear plant. The drive end was at 48VDC while the
motor saw 22VDC at its end. Everything ran fine but it did need 100uH
chokes in series with each motor lead at the drive to decouple the
cable capacitance, which was significant.
There is a "don't lower the river, raise the bridge" aspect here to
consider. Why not place the drive near the motor and run power down
the cable? Here's the tradeoff for a 7 Amp motor; 4 wires carrying 7
Amps each vs. 2 wires carrying 5 Amps or less (depending on load). Of
course you would have to send control signals as well, but the wire
gauge doesn't matter there.
Mariss
--- In CAD_CAM_EDM_DRO@egroups.com, "Chris Salter" <salterc@v...>
wrote:
feet for use in a nuclear plant. The drive end was at 48VDC while the
motor saw 22VDC at its end. Everything ran fine but it did need 100uH
chokes in series with each motor lead at the drive to decouple the
cable capacitance, which was significant.
There is a "don't lower the river, raise the bridge" aspect here to
consider. Why not place the drive near the motor and run power down
the cable? Here's the tradeoff for a 7 Amp motor; 4 wires carrying 7
Amps each vs. 2 wires carrying 5 Amps or less (depending on load). Of
course you would have to send control signals as well, but the wire
gauge doesn't matter there.
Mariss
--- In CAD_CAM_EDM_DRO@egroups.com, "Chris Salter" <salterc@v...>
wrote:
> Can someone give me advice on what is maximun distance.steppers...
>
> I want to be able to roll my plasma cutting table outside the shop
> approx. 25ft.
>
> Can I use around 25ft. of cable from the controller to the
>
>
> Thanks
>
> Chris
Discussion Thread
Chris Salter
2000-10-17 07:04:33 UTC
distance from controller to stepper
Dennis Bohlke
2000-10-17 07:30:11 UTC
Re: [CAD_CAM_EDM_DRO] distance from controller to stepper
Mariss Freimanis
2000-10-17 10:29:28 UTC
Re: distance from controller to stepper
beer@s...
2000-10-17 15:41:05 UTC
Re: distance from controller to stepper
Anne Ogborn
2000-10-17 17:56:17 UTC
Re: [CAD_CAM_EDM_DRO] Re: distance from controller to stepper
dougrasmussen@c...
2000-10-17 19:56:48 UTC
Re: distance from controller to stepper
Anne Ogborn
2000-10-17 21:59:22 UTC
Re: [CAD_CAM_EDM_DRO] Re: distance from controller to stepper
Darrell
2000-10-17 22:18:30 UTC
Re: [CAD_CAM_EDM_DRO] Re: distance from controller to stepper
Darrell
2000-10-17 22:20:34 UTC
Re: [CAD_CAM_EDM_DRO] Re: distance from controller to stepper
Jon Elson
2000-10-17 23:17:34 UTC
Re: [CAD_CAM_EDM_DRO] Re: distance from controller to stepper