Re: [CAD_CAM_EDM_DRO] EMC/Gecko/Parallel Port interface
Posted by
Jon Elson
on 2001-07-19 22:15:32 UTC
Alan Marconett KM6VV wrote:
limit
switches (one address) and what address is used for auxilliary (estop,
spindle,
coolant, etc) (another address). These are not limited in any way to the
standard parallel port addresses, as long as they follow the convention of
which bits in which address are "data bits" and which are "control bits"
in the fashion of the standard parallel port.
Jon
> Hi Allan,You edit the .ini file to tell it what address is used for stepper control and
>
> You might want to check through previous posts for more info.
> Previously, it has been suggested that you "steal" +5v from either the
> joystick connector, or the keyboard connector. A wall wart can also be
> used. You do NOT want to just hang a 5v regulator on the MOTOR +40v (or
> whatever) supply!
>
> I would assume that standard parallel ports at 378h, 278h, possibly even
> 3BCh would be recognized, as they are initially recognized and "mapped"
> (addresses recorded) into six words at addresses 40:8 in memory.
> Linux/EMC could either use these, or find them on it's own. At any
> rate, these standard addresses are you best bet. After that, Linux/EMC
> *MIGHT* do even more for you!
limit
switches (one address) and what address is used for auxilliary (estop,
spindle,
coolant, etc) (another address). These are not limited in any way to the
standard parallel port addresses, as long as they follow the convention of
which bits in which address are "data bits" and which are "control bits"
in the fashion of the standard parallel port.
Jon
Discussion Thread
allan_r9@h...
2001-07-19 18:53:06 UTC
EMC/Gecko/Parallel Port interface
Mike Gann
2001-07-19 19:02:19 UTC
Re: [CAD_CAM_EDM_DRO] EMC/Gecko/Parallel Port interface
Alan Marconett KM6VV
2001-07-19 19:36:08 UTC
Re: [CAD_CAM_EDM_DRO] EMC/Gecko/Parallel Port interface
Jon Elson
2001-07-19 22:15:32 UTC
Re: [CAD_CAM_EDM_DRO] EMC/Gecko/Parallel Port interface
Ian Wright
2001-07-20 02:30:14 UTC
Re: [CAD_CAM_EDM_DRO] EMC/Gecko/Parallel Port interface
Jon Elson
2001-07-20 10:24:46 UTC
Re: [CAD_CAM_EDM_DRO] EMC/Gecko/Parallel Port interface
Alan Marconett KM6VV
2001-07-20 12:58:30 UTC
Re: [CAD_CAM_EDM_DRO] EMC/Gecko/Parallel Port interface
Ian Wright
2001-07-20 14:26:10 UTC
Re: [CAD_CAM_EDM_DRO] EMC/Gecko/Parallel Port interface
Alan Marconett KM6VV
2001-07-20 14:40:26 UTC
Re: [CAD_CAM_EDM_DRO] EMC/Gecko/Parallel Port interface
Paul
2001-07-20 16:10:19 UTC
Re: [CAD_CAM_EDM_DRO] EMC/Gecko/Parallel Port interface
Alan Marconett KM6VV
2001-07-20 18:09:40 UTC
Re: [CAD_CAM_EDM_DRO] EMC/Gecko/Parallel Port interface
Jon Elson
2001-07-20 20:20:42 UTC
Re: [CAD_CAM_EDM_DRO] EMC/Gecko/Parallel Port interface
Ian Wright
2001-07-21 01:52:30 UTC
Re: [CAD_CAM_EDM_DRO] EMC/Gecko/Parallel Port interface
Paul
2001-07-21 03:07:47 UTC
Re: [CAD_CAM_EDM_DRO] EMC/Gecko/Parallel Port interface
Alan Marconett KM6VV
2001-07-21 10:53:55 UTC
Re: [CAD_CAM_EDM_DRO] EMC/Gecko/Parallel Port interface
Ian Wright
2001-07-21 11:39:45 UTC
Re: [CAD_CAM_EDM_DRO] EMC/Gecko/Parallel Port interface
Alan Marconett KM6VV
2001-07-21 12:09:11 UTC
Re: [CAD_CAM_EDM_DRO] EMC/Gecko/Parallel Port interface
Alan Marconett KM6VV
2001-07-21 12:20:18 UTC
Re: [CAD_CAM_EDM_DRO] EMC/Gecko/Parallel Port interface
Ian Wright
2001-07-21 13:36:47 UTC
Re: [CAD_CAM_EDM_DRO] EMC/Gecko/Parallel Port interface
Alan Marconett KM6VV
2001-07-21 15:09:16 UTC
Re: [CAD_CAM_EDM_DRO] EMC/Gecko/Parallel Port interface