CAD CAM EDM DRO - Yahoo Group Archive

Re: mill

on 2000-01-13 13:26:05 UTC
It is fairly easy to run 460 volts three phase in the home shop. I do it
all the time. For bigger stuff, I run a 240 volt rotary phase converter and
step it up to 480 volts with a three phase transformer. For smaller stuff,
I run 236 volts single phase through a single phase step up transformer to
feed an inverter VFD that puts out 3 phase.

cvl

Discussion Thread

Al Schoepp 2000-01-13 09:01:20 UTC mill Al Schoepp 2000-01-13 10:12:25 UTC Re: mill PTENGIN@x... 2000-01-13 10:25:34 UTC Re: mill Darrell 2000-01-13 10:40:27 UTC Re: mill Charles VanLeeuwen 2000-01-13 13:26:05 UTC Re: mill Steve Carlisle 2000-01-13 18:40:51 UTC Re: mill Darrell 2000-01-13 17:24:05 UTC Re: mill Steve Carlisle 2000-01-13 18:55:27 UTC Re: mill Jon Elson 2000-01-13 23:09:54 UTC Re: mill Paul Corner 2000-01-14 11:48:15 UTC Re: mill