CAD CAM EDM DRO - Yahoo Group Archive

Re: [CAD_CAM_EDM_DRO] VFD's

Posted by Jon Elson
on 2002-11-08 23:18:23 UTC
Mike Gann wrote:

>Jon -
>
>Do you think it would be a problem running a 1.5 HP motor on a 3 HP
>inverter?
>
>
No. This is VERY standard practice, especially when running a nominally
3-phase input only
VFD on single phase 220 V. Generally, you don't want to go too far this
way, but 2 x is fine.

Jon

Discussion Thread

johnhe 2001-10-04 10:44:13 UTC Re: [CAD_CAM_EDM_DRO] Re: VFD's valrox1 2002-01-30 12:08:30 UTC VFD's Tim Goldstein 2002-11-07 16:37:30 UTC Re: [CAD_CAM_EDM_DRO] VFD's Mike Gann 2002-11-07 19:10:59 UTC Re: [CAD_CAM_EDM_DRO] VFD's Jon Elson 2002-11-07 23:02:09 UTC Re: [CAD_CAM_EDM_DRO] VFD's turbulatordude 2002-11-08 04:36:03 UTC Re: VFD's doug98105 2002-11-08 06:12:40 UTC Re: VFD's jmkasunich 2002-11-08 06:40:09 UTC Re: VFD's bjammin@i... 2002-11-08 09:34:39 UTC Re: [CAD_CAM_EDM_DRO] Re: VFD's Mike Gann 2002-11-08 19:14:09 UTC Re: [CAD_CAM_EDM_DRO] VFD's Jon Elson 2002-11-08 22:33:18 UTC Re: [CAD_CAM_EDM_DRO] Re: VFD's Jon Elson 2002-11-08 22:39:53 UTC Re: [CAD_CAM_EDM_DRO] Re: VFD's Jon Elson 2002-11-08 23:18:23 UTC Re: [CAD_CAM_EDM_DRO] VFD's turbulatordude 2002-11-10 14:15:48 UTC Re: VFD's Jon Elson 2002-11-10 22:26:32 UTC Re: [CAD_CAM_EDM_DRO] Re: VFD's turbulatordude 2002-11-11 04:36:13 UTC Re: VFD's jmkasunich 2002-11-11 08:05:27 UTC Re: VFD's Jon Elson 2002-11-11 11:23:30 UTC Re: [CAD_CAM_EDM_DRO] Re: VFD's jmkasunich 2002-11-11 13:21:15 UTC Re: VFD's