CAD CAM EDM DRO - Yahoo Group Archive

Re: Blown Gecko 340

Posted by andyolney
on 2003-06-17 22:53:03 UTC
Jon wrote:

> Yup, clearly LOTS of head room. I'm starting to think it may be a
> > bad motor with an intermittent short. Just another thought, is
this
> > the SAME gecko drive that was repaired before? Maybe there is an
> > intermittent problem in the control logic that was not fully
> repaired
> > before?
> >
> > Jon

Jon - I tested the motor with a 1.5vdc source with an ampmeter in
series. Turned smoothly with no hesitation and the meter was very
steady at .12 amp. FWIW the resistance of the motor is 2 to 6 ohms
depending on the armature position. Resistance between motor leads
and case was higher than the meter could read. Fluke 77.

Any thoughts? Andy

Discussion Thread

andyolney 2003-06-15 21:16:06 UTC Blown Gecko 340 JanRwl@A... 2003-06-15 22:19:08 UTC Re: [CAD_CAM_EDM_DRO] Blown Gecko 340 Jon Elson 2003-06-15 22:28:23 UTC Re: [CAD_CAM_EDM_DRO] Blown Gecko 340 andyolney 2003-06-16 09:10:18 UTC Re: Blown Gecko 340 Jon Elson 2003-06-16 10:34:52 UTC Re: [CAD_CAM_EDM_DRO] Re: Blown Gecko 340 andyolney 2003-06-16 21:19:55 UTC Re: Blown Gecko 340 andyolney 2003-06-17 22:53:03 UTC Re: Blown Gecko 340 Lee Studley 2003-06-18 10:17:32 UTC Re: Blown Gecko 340 Jon Elson 2003-06-18 10:50:50 UTC Re: [CAD_CAM_EDM_DRO] Re: Blown Gecko 340 andyolney 2003-06-22 15:34:39 UTC Re: Blown Gecko 340 Update Jon Elson 2003-06-27 20:26:02 UTC Re: [CAD_CAM_EDM_DRO] Re: Blown Gecko 340 Update andyolney 2003-06-27 22:04:43 UTC Re: Blown Gecko 340 Update Lee Studley 2003-06-27 23:35:05 UTC Re: Blown Gecko 340 Update Dan Mauch 2003-07-14 10:51:50 UTC Interesting problem Fred Smith 2003-07-14 15:18:27 UTC Re: Interesting problem stevenson_engineers 2003-07-14 17:31:43 UTC Re: Interesting problem