CAD CAM EDM DRO - Yahoo Group Archive

Re: [CAD_CAM_EDM_DRO] Transformer Soft Start

Posted by Ted Walls
on 2003-07-03 10:28:14 UTC
tiffyted wrote:

>Can anyone in this group advise me on a suitable circuit for soft
>starting a 230v primary, 40v secondary 1000VA toriordal transformer.

Jon Elson Replied:

I think you have something serious wrong, here. I don't think soft start
will help you.....

Thanks for the reply Jon,

The transformer is 230v only primary and 2 x 40v 12.5A secondary. As
supplied by RS. It currently is not connected to any rectification circuit
and the secondary windings are open circuit.

I have checked the data sheet which indicates the normal running current
would be 4.34A. However, there is a paragraph that states the start current
can momentarily be as much as 67 times this, which would blow the fuse. This
is what led me to assume I needed a soft start system.

Les Newell has suggested that I use a surge arrester. I think if they are
not too pricey I'll get one to try. If it works Ok I'll let you all know. If
not I'll have to look into it a bit deeper.

Thanks again to all for their replies.

Discussion Thread

tiffyted 2003-07-03 02:25:45 UTC Transformer Soft Start Les Newell 2003-07-03 05:35:57 UTC Re: [CAD_CAM_EDM_DRO] Transformer Soft Start rainnea 2003-07-03 06:54:12 UTC Re: Transformer Soft Start Tim Goldstein 2003-07-03 08:01:56 UTC RE: [CAD_CAM_EDM_DRO] Transformer Soft Start Les Newell 2003-07-03 08:23:13 UTC Re: [CAD_CAM_EDM_DRO] Re: Transformer Soft Start Jon Elson 2003-07-03 08:43:24 UTC Re: [CAD_CAM_EDM_DRO] Transformer Soft Start Carl Mikkelsen 2003-07-03 09:37:19 UTC Re: [CAD_CAM_EDM_DRO] Transformer Soft Start Tony Jeffree 2003-07-03 10:11:03 UTC Re: [CAD_CAM_EDM_DRO] Transformer Soft Start Ted Walls 2003-07-03 10:28:14 UTC Re: [CAD_CAM_EDM_DRO] Transformer Soft Start Tim Goldstein 2003-07-03 10:36:48 UTC RE: [CAD_CAM_EDM_DRO] Transformer Soft Start wanliker@a... 2003-07-03 10:57:05 UTC Transformer Soft Start Keith Bowers 2003-07-03 11:22:13 UTC Re: [CAD_CAM_EDM_DRO] Transformer Soft Start caudlet 2003-07-03 12:51:15 UTC Re: Transformer Soft Start rainnea 2003-07-03 13:30:39 UTC Re: Transformer Soft Start Les Newell 2003-07-03 14:03:03 UTC Re: [CAD_CAM_EDM_DRO] Re: Transformer Soft Start Paul 2003-07-03 14:38:13 UTC Re: [CAD_CAM_EDM_DRO] Re: Transformer Soft Start Bob Simon 2003-07-03 14:44:23 UTC Re: [CAD_CAM_EDM_DRO] Re: Transformer Soft Start caudlet 2003-07-03 17:23:16 UTC Re: Transformer Soft Start Jon Elson 2003-07-03 21:43:02 UTC Re: [CAD_CAM_EDM_DRO] Transformer Soft Start Jon Elson 2003-07-03 21:52:19 UTC Re: [CAD_CAM_EDM_DRO] Transformer Soft Start Graham Stabler 2003-07-04 03:31:28 UTC Re: Transformer Soft Start