shelbyshepherd2002 wrote:

>I am using Yeager CNCPRO to contol an X Y table. Can someone suggest
>the solution to trigger an electric solinoid (12 or 24 volt) switch
>for an air ram?
>The table will move 50 mm then stops and the ram activates, this
>process goes for 30 times and then back to the start.
>If a relay is used what type is needed to suit and how is it wired
>into the system?
>If someone out there has a better idea, I would like to know there
>thoughts.
>
>
I've used a Crydom D2W202F solid state relay (available for about $8
from Digi-Key) to control spindle relays, solenoid valves, etc. They
work quite well from parallel port signals. they work best when the
+ terminal is connected to +5V from the computer, and the - pin
is connected to the parallel port signal.

These relays switch up to 2A at 240 VAC. They work fine on 24 V AC.
I don't know if they will work properly on 12 V AC. For DC, there are
other SSR models that can do it. You'd need an SSR specifically made for
DC output.

Jon

Discussion Thread

shelbyshepherd2002 2003-07-11 16:32:17 UTC Relay to operate soliniod or other idea? JanRwl@A... 2003-07-11 16:55:48 UTC Re: [CAD_CAM_EDM_DRO] Relay to operate soliniod or other idea? shelbyshepherd2002 2003-07-11 21:50:21 UTC Re: Relay to operate soliniod or other idea? Jon Elson 2003-07-11 23:59:30 UTC Re: [CAD_CAM_EDM_DRO] Relay to operate soliniod or other idea? JanRwl@A... 2003-07-12 14:20:09 UTC Re: [CAD_CAM_EDM_DRO] Re: Relay to operate soliniod or other idea? shelbyshepherd2002 2003-07-12 18:11:33 UTC Re: Relay to operate soliniod or other idea? ron_routledge 2003-07-13 17:55:42 UTC Re: Relay to operate soliniod or other idea? turbulatordude 2003-07-13 18:35:32 UTC Re: Relay to operate soliniod or other idea?