On Wed, 5 Nov 2003 22:52:51 -0500, you wrote:
the current in setting the motor current.
Recommendations are to use full current hooked up as half coil motors,
bipolar drive. The 2 amps is what they would handle in normal current
limited unipolar "wave" or "full step" drive, so that's fine.
Harvey
>These are 6 wire Vexta PK-268M-02A motors, 400 step per rev, 2 AMP, 2.25 OhmFull coil gives twice the inductance and you use approximately half
>motors. I have tried running them using the full coil connections and they
>do not perform well in my setup. I have now hooked them up using 1/2 coil
>mode, center tap and 1 end connection, for each phase and they work fine.
>My concern is that 2 AMPs may be more than the windings can stand in this
>mode.
the current in setting the motor current.
Recommendations are to use full current hooked up as half coil motors,
bipolar drive. The 2 amps is what they would handle in normal current
limited unipolar "wave" or "full step" drive, so that's fine.
Harvey
>