Re: Gecko 320 with external encoder power supply
Posted by
wayne_j_hill
on 2004-01-01 16:05:04 UTC
> Orange CH A+ This goes to Phase A on thedrive
> Green CH A- Where does this go?Not Used
> Yellow CH B+ This goes to Phase B on thedrive
> Blue CH B- Where does this go?Not Used
> Brown CH Z+ I understand that this is not used.Not Used
> Grey CH Z- I understand that this is not used.Not Used
> Red CH +5v +5v from my power supply goesdirectly to this.
> Black Common Where does this go?Signal Ground
> Shield Drain Where is the best place todrain this to?
Earth Ground or Not Used
Hope this can helps
Discussion Thread
andrebarclay
2004-01-01 12:10:55 UTC
Gecko 320 with external encoder power supply
Gregory Kamysz
2004-01-01 12:25:22 UTC
Re: [CAD_CAM_EDM_DRO] Gecko 320 with external encoder power supply
Mariss Freimanis
2004-01-01 13:07:13 UTC
Re: Gecko 320 with external encoder power supply
wayne_j_hill
2004-01-01 16:05:04 UTC
Re: Gecko 320 with external encoder power supply
Jon Elson
2004-01-01 19:33:36 UTC
Re: [CAD_CAM_EDM_DRO] Gecko 320 with external encoder power supply
andrebarclay
2004-01-01 20:18:30 UTC
Re: Gecko 320 with external encoder power supply