CAD CAM EDM DRO - Yahoo Group Archive

Re: [CAD_CAM_EDM_DRO] VEXTA STEPPER HELP

Posted by james owens
on 2000-05-21 10:43:53 UTC
Hi Bill,

The wiring on your steppers are RED (a) white (centre tap) BLUE (b), the other coil is BLACK (c) YELLOW (centre tap) GREEN (d).

* RED * BLACK
) )
) )
* WHITE (ct) * YELLOW (ct)
) )
) )
* BLUE * GREEN

Are they TYPE 23 or TYPE 34 frame, and what is the oz./in rating anything over about 100oz will do but 200oz is better.

Regards,

Terry


I have 3 VEXTS PH265M-31 steppers, .9 degrees, 2 phase 6 volt, .85 amp.

Does anyone on the list have any information on these units, and are they big
enough for a SHERLINE Mill, direct drive.

Any help would be greatly appreciated. Especially the specifications. And
the wiring diagram, 6 wire.
White, yellow, green, black, blue, and red. I have not put a meter to them
yet.
Thanks,
bill



[Non-text portions of this message have been removed]

Discussion Thread

wanliker@a... 2000-05-20 22:07:12 UTC VEXTA STEPPER HELP Tim Goldstein 2000-05-20 22:27:33 UTC RE: [CAD_CAM_EDM_DRO] VEXTA STEPPER HELP DRigotti@A... 2000-05-21 04:23:32 UTC Re: [CAD_CAM_EDM_DRO] VEXTA STEPPER HELP wanliker@a... 2000-05-21 07:17:56 UTC Re: [CAD_CAM_EDM_DRO] VEXTA STEPPER HELP Steve Carlisle 2000-05-21 08:04:17 UTC Re: [CAD_CAM_EDM_DRO] VEXTA STEPPER HELP james owens 2000-05-21 10:43:53 UTC Re: [CAD_CAM_EDM_DRO] VEXTA STEPPER HELP Bob Bachman 2000-05-21 13:34:24 UTC Re: [CAD_CAM_EDM_DRO] More VEXTA STEPPER HELP Needed Steve Carlisle 2000-05-21 13:54:23 UTC Re: [CAD_CAM_EDM_DRO] More VEXTA STEPPER HELP Needed JanRwl@A... 2000-05-21 14:11:34 UTC Re: [CAD_CAM_EDM_DRO] More VEXTA STEPPER HELP Needed JanRwl@A... 2000-05-21 14:18:28 UTC Re: [CAD_CAM_EDM_DRO] VEXTA STEPPER HELP Bob Bachman 2000-05-21 14:30:30 UTC Re: [CAD_CAM_EDM_DRO] More VEXTA STEPPER HELP Needed james owens 2000-05-21 18:23:34 UTC Re: [CAD_CAM_EDM_DRO] VEXTA STEPPER HELP