CAD CAM EDM DRO - Yahoo Group Archive

Re: [CAD_CAM_EDM_DRO] Re: Calculating the VA rating of transformers? dims

Posted by JanRwl@A...
on 2005-02-14 17:34:13 UTC
In a message dated 2/14/2005 9:10:21 A.M. Central Standard Time,
dave_mucha@... writes:

But you can easily find the thickness as the thickness of all the
laminations is the same as the core.



Thanks, Dave, but this assumes the "stack" has been made the same as the
core-width (middle leg width). It is often NOT! The thickness is usually MORE
than the core-width!

With vernier calipers, or even a good ruler, one can USUALLY see the edges
of the core right as it enters the winding. I suspect 4.5" is NOT a linear
width in this instance, and am waiting for corrected values.

JRR


[Non-text portions of this message have been removed]

Discussion Thread

Martin de Roode 2005-02-10 21:06:36 UTC How can i change my link ? Wayne 2005-02-11 05:58:42 UTC Re: [CAD_CAM_EDM_DRO] How can i change my link ? turbulatordude 2005-02-11 06:51:43 UTC Re: How can i change my link ? turbulatordude 2005-02-13 17:04:15 UTC Re: How can i change my link ? R Rogers 2005-02-13 18:12:43 UTC [CAD_CAM_EDM_DRO] Calculating the VA rating of transformers? JanRwl@A... 2005-02-13 22:47:09 UTC Re: [CAD_CAM_EDM_DRO] Calculating the VA rating of transformers? R Rogers 2005-02-14 05:43:45 UTC Re: [CAD_CAM_EDM_DRO] Calculating the VA rating of transformers? dims turbulatordude 2005-02-14 07:05:25 UTC Re: Calculating the VA rating of transformers? dims R Rogers 2005-02-14 08:52:23 UTC Re: [CAD_CAM_EDM_DRO] Re: Calculating the VA rating of transformers? dims deepcavity 2005-02-14 10:44:06 UTC Re: [CAD_CAM_EDM_DRO] Calculating the VA rating of transformers? turbulatordude 2005-02-14 10:47:09 UTC Re: Calculating the VA rating of transformers? Andrew Mawson 2005-02-14 11:01:53 UTC Re: Calculating the VA rating of transformers? turbulatordude 2005-02-14 14:05:51 UTC Re: Calculating the VA rating of transformers? JanRwl@A... 2005-02-14 17:05:58 UTC Re: [CAD_CAM_EDM_DRO] Calculating the VA rating of transformers? dims JanRwl@A... 2005-02-14 17:34:13 UTC Re: [CAD_CAM_EDM_DRO] Re: Calculating the VA rating of transformers? dims turbulatordude 2005-02-14 17:49:31 UTC Re: Calculating the VA rating of transformers? dims R Rogers 2005-02-14 17:51:53 UTC Re: [CAD_CAM_EDM_DRO] Re: Calculating the VA rating of transformers? dims JanRwl@A... 2005-02-14 17:54:48 UTC Re: [CAD_CAM_EDM_DRO] Calculating the VA rating of transformers? cnc_4_me 2005-02-14 19:18:11 UTC Re: Calculating the VA rating of transformers? JanRwl@A... 2005-02-14 23:05:25 UTC Re: [CAD_CAM_EDM_DRO] Re: Calculating the VA rating of transformers? JanRwl@A... 2005-02-14 23:41:12 UTC Re: [CAD_CAM_EDM_DRO] Re: Calculating the VA rating of transformers? dims JanRwl@A... 2005-02-14 23:56:12 UTC Re: [CAD_CAM_EDM_DRO] Re: Calculating the VA rating of transformers? caudlet 2005-02-15 22:34:56 UTC Re: Calculating the VA rating of transformers? turbulatordude 2005-02-16 08:24:28 UTC Re: Calculating the VA rating of transformers? JanRwl@A... 2005-02-16 17:08:34 UTC Re: [CAD_CAM_EDM_DRO] Re: Calculating the VA rating of transformers? caudlet 2005-02-16 20:43:06 UTC Re: Calculating the VA rating of transformers?