CAD CAM EDM DRO - Yahoo Group Archive

RE: [CAD_CAM_EDM_DRO] Static electricity - WOW

on 2010-02-28 19:26:42 UTC
Hi Randy and all:
     This the reason many of small grain mills have been closed in Michigan is because of the fire hazard cause by the dust.
     I notice you you said you have been working in industry for 26 years so you may remember some of the first conversions from NC to DNC or now CNC by what was often called drip feeding.  This is where the RS232 signal was sent to the tape reader control to a connection just behind the tape reader.  What it does is use a signal the same as the tape reader put out but, it gets it from the computer.  What I have forgotten in the last 17 years since I helped do it on a Bridgeport Mill is how the signal was generated on the computer.  As close as I can remember is we used note pad to generate the text needed for each block of G or M code with all the proper dividers.The carriage return was the end of block if I remember right. 
    My question is do you any more about the setup as I am looking as a NC lathe in GOOD condition that I would attach this type of computer control.  Thanks in advance for your time and answers.
                                                         GOD'S BLESSINGS
                                                                   Bill

On Tue, 23 Feb 2010 13:01:15 -0800 (PST), RANDY ABERNATHY wrote
>  
>
> Jeff:
>  
> If you paid close attention to my post you will see I recommend first a ground line back to the distrubution box and THEN for a backup, mainly to help prevent interference with the electronics, a ground rod near the machine.
>  
> As far as wood dust exploding being an uban legend, you must not have looked hard enough.  It is not a common everyday occurance but it does occur.  And yes it does occur sometimes from static electricity.  I have been to 2 factories over the 26 years or so I have been in this industry where they were totally destroyed by explosion of wood dust.  One of these, it was determined by the investigators, was caused by a maintenance man repairing a section of the dust collector pipe with PVC.  That section caused a big static buildup and ultimately caused a spark inside the pipe, which melted and the fire spread.
>  
> You are correct about proper dust collection helping to prevent this type of thing, the key is PROPER dust collection and I am afraid there are a lot of people out there that either don't know how to do this or just don't want to spend the money or time.
>  
> Stay safe.
>
> Randy Abernathy
> CNC and Industrial Machinery
> service, repair, installation and
> design
>
> 4626 Old Stilesboro Rd NW
> Acworth, GA 30101
> Fax: 770-974-5295
> Phone: 678-982-0235
> E-mail:
> randyabernathy@...
>
> --- On Mon, 2/22/10, Jeffrey T. Birt <birt_j@...> wrote:
>
> From: Jeffrey T. Birt <birt_j@...>
> Subject: RE: [CAD_CAM_EDM_DRO] Static electricity - WOW
> To: CAD_CAM_EDM_DRO@yahoogroups.com
> Date: Monday, February 22, 2010, 7:01 PM
>
>  
>
> >On large industrial machines we often ran a separate ground wire from the machine chassis directly to a grounding rod driven into the ground >thru a hole drilled in the concrete floor of the factory or shop.
>
> Hopefully your bonding this to the main supply ground? Most earth ground driven inside of a factory are next to useless as the ground is too dry to provide a good ground at all.
>
> >Many of the fires in woodworking factories start in the dust collection system from static sparks because of improper grounding or using PVC or >other polymer material in the dust collection tubing.
>
> Urban legend as far as I have ever been able to find out. I have found no documented cases of the cause of a fire at a wood working plant being caused by a static discharge (but I would love to see it.). A grain mill would be much more likely and then it is from having just the right combination of flour dust to air, controlling the dust takes care of most of the problem.
>
> Jeff Birt
>
> Check out [UTF-8?]– [UTF-8?]Soigeneris.com…
>
> From: CAD_CAM_EDM_ DRO@yahoogroups. com [mailto:CAD_CAM_EDM_ DRO@yahoogroups. com] On Behalf Of RANDY ABERNATHY
> Sent: Monday, February 22, 2010 5:23 PM
> To: CAD_CAM_EDM_ DRO@yahoogroups. com
> Subject: Re: [CAD_CAM_EDM_ DRO] Static electricity - WOW
>
> YES, the machine should have a ground run with the power line which is also connected to the machine chassis. On large industrial machines we often ran a separate ground wire from the machine chassis directly to a grounding rod driven into the ground thru a hole drilled in the concrete floor of the factory or shop.
>
> Are you using PVC by any chance anywhere between your dust collector unit and the machine? If so, get rid of it and put metal pipe instead. If you are using a small portable dust collector or a shop vacuum with plastic head on it, you probably should ground the hose going to your machine.
>
> One other thing you need to know is that wood dust can ignite and explode from even a small spark. Many of the fires in woodworking factories start in the dust collection system from static sparks because of improper grounding or using PVC or other polymer material in the dust collection tubing.
>
> Hope this helps out.
>
> Randy Abernathy
> CNC and Industrial Machinery
> service, repair, installation and
> design
>
> 4626 Old Stilesboro Rd NW
> Acworth, GA 30101
> Fax: 770-974-5295
> Phone: 678-982-0235
> E-mail:
> randyabernathy@ bellsouth. net <mailto:randyaberna thy%40bellsouth. net>
>
> --- On Mon, 2/22/10, Jack <freshwatermodels@ yahoo.com <mailto:freshwaterm odels%40yahoo. com> > wrote:
>
> From: Jack <freshwatermodels@ yahoo.com <mailto:freshwaterm odels%40yahoo. com> >
> Subject: [CAD_CAM_EDM_ DRO] Static electricity - WOW
> To: CAD_CAM_EDM_ DRO@yahoogroups. com <mailto:CAD_ CAM_EDM_DRO% 40yahoogroups. com>
> Date: Monday, February 22, 2010, 2:32 PM
>
> I guess I have a static electricity problem. While cutting a model boat
> stand on my router I was using a dust collector . I was holding the
> hose by hand. Something touched something else and both I and my
> computer got a jolt of static electricity. Has anyone else run into
> this? Cures???
>
> I am assuming I need to ground the router which is aluminum on a wood
> stand. Do I need to somehow ground the plastic hose on the dust
> collector?
>
> Any suggestions, insight, etc. appreciated! !!!!!!!!! !
>
> jack
>
> [Non-text portions of this message have been removed]
>
> [Non-text portions of this message have been removed]
>
> [Non-text portions of this message have been removed]
>
>

--
Open WebMail Project (http://openwebmail.org)




[Non-text portions of this message have been removed]

Discussion Thread

Jack 2010-02-22 11:36:01 UTC Static electricity - WOW H & J Johnson 2010-02-22 11:49:44 UTC Re: [CAD_CAM_EDM_DRO] Static electricity - WOW Jeffrey T. Birt 2010-02-22 12:45:16 UTC RE: [CAD_CAM_EDM_DRO] Static electricity - WOW Jack McKie 2010-02-22 13:14:35 UTC RE: [CAD_CAM_EDM_DRO] Static electricity - WOW Thomas Gammon 2010-02-22 15:51:29 UTC Re: [CAD_CAM_EDM_DRO] Static electricity - WOW RANDY ABERNATHY 2010-02-22 15:52:50 UTC RE: [CAD_CAM_EDM_DRO] Static electricity - WOW RANDY ABERNATHY 2010-02-22 15:52:54 UTC Re: [CAD_CAM_EDM_DRO] Static electricity - WOW Jeffrey T. Birt 2010-02-22 15:57:07 UTC RE: [CAD_CAM_EDM_DRO] Static electricity - WOW Jack McKie 2010-02-22 16:05:28 UTC RE: [CAD_CAM_EDM_DRO] Static electricity - WOW Jeffrey T. Birt 2010-02-22 17:17:07 UTC RE: [CAD_CAM_EDM_DRO] Static electricity - WOW Jon Elson 2010-02-22 19:13:26 UTC Re: [CAD_CAM_EDM_DRO] Static electricity - WOW Dave Panetta(The Spam Catcher) 2010-02-23 07:22:18 UTC Re:Static electricity - WOW Jack McKie 2010-02-23 07:32:12 UTC Re: [CAD_CAM_EDM_DRO] Re:Static electricity - WOW RANDY ABERNATHY 2010-02-25 11:03:51 UTC RE: [CAD_CAM_EDM_DRO] Static electricity - WOW William Thomas 2010-02-28 19:26:42 UTC RE: [CAD_CAM_EDM_DRO] Static electricity - WOW RANDY ABERNATHY 2010-03-08 14:13:41 UTC RE: [CAD_CAM_EDM_DRO] Static electricity - WOW Michael Milligan 2010-03-09 09:35:23 UTC RE: [CAD_CAM_EDM_DRO] Static electricity - WOW RANDY ABERNATHY 2010-03-09 10:44:50 UTC RE: [CAD_CAM_EDM_DRO] Static electricity - WOW William Thomas 2010-03-12 17:22:26 UTC RE: [CAD_CAM_EDM_DRO] NC drip feed RANDY ABERNATHY 2010-03-13 01:37:48 UTC RE: [CAD_CAM_EDM_DRO] NC drip feed