Re: Toothed pully design information needed.
Posted by
ballendo@y...
on 2000-11-11 04:25:05 UTC
Peter,
Good advice on the HTD style belts. I'll never use the Xl(trapezoid)
again, given Any sort of choice.
I cut pulleys for htd from aluminum bar stock with a ball-end mill in
the early 90's. That machine is still producing good work (sign
router). The calcs were from the (then) current Stock Drive parts
catalog.
Hope this helps.
Ballendo
P.S. ORDER "one" in the size you need, make hundreds...
Like mariss recently mentioned, Empirical "leads" theoretical.
Good advice on the HTD style belts. I'll never use the Xl(trapezoid)
again, given Any sort of choice.
I cut pulleys for htd from aluminum bar stock with a ball-end mill in
the early 90's. That machine is still producing good work (sign
router). The calcs were from the (then) current Stock Drive parts
catalog.
Hope this helps.
Ballendo
P.S. ORDER "one" in the size you need, make hundreds...
Like mariss recently mentioned, Empirical "leads" theoretical.
>>Yes, it would be nice to be able to cut timing belt pulleys. But
>>don't you use a flycutter for someting like that?
>BTW, see if information on HTD profile belts can be found as I
>believe the profile is easier to cut. The teeth are deeper so the
>sprocket is probably more forgiving of imperfections of the cut
>profile etc. Also, since the teeth are deeper, the belts are less ?
>prone to skipping under load.
>Peter
Discussion Thread
wanliker@a...
2000-11-09 21:53:55 UTC
Toothed pully design information needed.
Wally K
2000-11-10 00:44:36 UTC
Re: Toothed pully design information needed.
Alan Marconett KM6VV
2000-11-10 11:16:30 UTC
Re: [CAD_CAM_EDM_DRO] Toothed pully design information needed.
Smoke
2000-11-10 11:41:20 UTC
Re: [CAD_CAM_EDM_DRO] Toothed pully design information needed.
wanliker@a...
2000-11-10 18:53:55 UTC
Re: [CAD_CAM_EDM_DRO] Toothed pully design information needed.
wanliker@a...
2000-11-10 18:54:04 UTC
Re: [CAD_CAM_EDM_DRO] Toothed pully design information needed.
Smoke
2000-11-10 21:30:45 UTC
Re: [CAD_CAM_EDM_DRO] Toothed pully design information needed.
ptengin@a...
2000-11-10 21:39:03 UTC
Re: [CAD_CAM_EDM_DRO] Toothed pully design information needed.
Brian Pitt
2000-11-10 22:22:20 UTC
Re: [CAD_CAM_EDM_DRO] Toothed pully design information needed.
ballendo@y...
2000-11-11 04:25:05 UTC
Re: Toothed pully design information needed.
Smoke
2000-11-11 09:12:35 UTC
Re: [CAD_CAM_EDM_DRO] Re: Toothed pully design information needed.
machines@n...
2000-11-11 09:45:14 UTC
Re: Toothed pully design information needed.
Smoke
2000-11-11 11:00:08 UTC
Re: [CAD_CAM_EDM_DRO] Re: Toothed pully design information needed.
ptengin@a...
2000-11-11 15:05:09 UTC
Re: [CAD_CAM_EDM_DRO] Toothed pully design information needed.
Ian Wright
2000-11-11 15:13:30 UTC
Re: [CAD_CAM_EDM_DRO] Toothed pully design information needed.
ptengin@a...
2000-11-11 15:42:42 UTC
Re: [CAD_CAM_EDM_DRO] Re: Toothed pully design information needed.
ballendo@y...
2000-11-11 15:43:18 UTC
Re: Re: Toothed pully design information needed.
machines@n...
2000-11-11 15:53:55 UTC
Re: Toothed pully design information needed.
wanliker@a...
2000-11-11 16:22:04 UTC
Re: [CAD_CAM_EDM_DRO] Toothed pully design information needed.
Smoke
2000-11-11 20:13:33 UTC
Re: [CAD_CAM_EDM_DRO] Re: Toothed pully design information needed.