CAD CAM EDM DRO - Yahoo Group Archive

Re: [CAD_CAM_EDM_DRO] EMC signal output

Posted by Jon Elson
on 2001-05-08 15:54:58 UTC
Art Fenerty wrote:

> You guys might wanta take note that the new Gekko 210's require that the DIR
> signal stay in the proper polarity for up to 100uS after the step pulse.

100 uS ? Are you sure? That sounds awfully excessive for setup/hold
times. I thought I was being rediculous giving up to 25.5 uS setup/hold
time on my parallel port step rate generator! This seems like it might limit
you to 10,000 steps/sec, which could be a problem for step multiplying drives.

Jon

Discussion Thread

Cryo 2001-05-08 11:57:31 UTC EMC signal output Jon Elson 2001-05-08 13:21:15 UTC Re: [CAD_CAM_EDM_DRO] EMC signal output Art Fenerty 2001-05-08 14:03:11 UTC Re: [CAD_CAM_EDM_DRO] EMC signal output Tim Goldstein 2001-05-08 14:08:07 UTC RE: [CAD_CAM_EDM_DRO] EMC signal output Jon Elson 2001-05-08 15:54:58 UTC Re: [CAD_CAM_EDM_DRO] EMC signal output Jon Elson 2001-05-08 23:33:01 UTC Re: [CAD_CAM_EDM_DRO] EMC signal output Jon Elson 2001-05-08 23:39:23 UTC Re: [CAD_CAM_EDM_DRO] EMC signal output Cryo 2001-05-09 05:17:59 UTC Re[2]: [CAD_CAM_EDM_DRO] EMC signal output Jon Elson 2001-05-09 08:26:49 UTC Re: [CAD_CAM_EDM_DRO] EMC signal output Tim Goldstein 2001-05-09 09:08:21 UTC RE: [CAD_CAM_EDM_DRO] EMC signal output ballendo@y... 2001-05-10 03:29:20 UTC Re: EMC signal output Jon Elson 2001-05-13 23:26:16 UTC Re: [CAD_CAM_EDM_DRO] EMC signal output