CAD CAM EDM DRO - Yahoo Group Archive

Re[2]: [CAD_CAM_EDM_DRO] EMC signal output

Posted by Cryo
on 2001-05-09 05:17:59 UTC
Hello Jon,

How do you know what kind of machine I have ?

As far as I know I need a pulse like that and now I need to know how
to do that. Do I have to write some C-code or is there any settings on
that?

You mentioned your "step rate generator". Where I can get that, if I
can get that?

--
Cryo - Cryo@...

--- Original Message ---
JE> Cryo wrote:

>> I didn't find any documentation about EMC's port settings.
>> Can I change step/dir signal polarity easily somewhere?
>> My driver needs signal which is normally down and when step coms is
>> up.
>>
>> Another thing is timing. Can I change pulse width and other that kind
>> of stuff somewhere?
>> I need signal which is like this:
>>
>> step |---| |---|
>> ----| |-------| |----
>>
>> dir |-------| |-------|
>> ---| |---| |-
>>
>> I put oscilloscope to EMC output and it's like:
>>
>> step |---| |---|
>> ----| |----| |----
>>
>> dir |------------|
>> ----| |----
>>

JE> I don't see the problem here. It should be legal for the direction
JE> signal to stay at the same polarity if two consecutive steps will be in
JE> the same direction. The only concern is that the direction signal does not
JE> change too close to the active edge of the step signal (which can be the
JE> rising or falling edge, depending on the step driver).

JE> The polarity of the step signal is also not generally important, except
JE> for the relationship to changes in the direction not ocurring too close
JE> to the active transition.

JE> My parallel port step rate generator does allow the width of the step
JE> pulse, as well as the setup time delays around the active edge of the step
JE> signal to be controlled. I will probably put polarity switching logic
JE> in the final version of this.

JE> Jon


JE> Welcome to CAD_CAM_EDM_DRO@...,an unmoderated list for the discussion of shop built systems, for CAD, CAM, EDM, and DRO.

JE> Addresses:
JE> Post message: CAD_CAM_EDM_DRO@yahoogroups.com
JE> Subscribe: CAD_CAM_EDM_DRO-subscribe@yahoogroups.com
JE> Unsubscribe: CAD_CAM_EDM_DRO-unsubscribe@yahoogroups.com
JE> List owner: CAD_CAM_EDM_DRO-owner@yahoogroups.com, wanliker@...
JE> Moderator: jmelson@... timg@... [Moderator]
JE> URL to this page: http://groups.yahoo.com/group/CAD_CAM_EDM_DRO
JE> bill,
JE> List Manager

JE> FAQ: http://www.ktmarketing.com/faq.html

JE> Your use of Yahoo! Groups is subject to http://docs.yahoo.com/info/terms/

Discussion Thread

Cryo 2001-05-08 11:57:31 UTC EMC signal output Jon Elson 2001-05-08 13:21:15 UTC Re: [CAD_CAM_EDM_DRO] EMC signal output Art Fenerty 2001-05-08 14:03:11 UTC Re: [CAD_CAM_EDM_DRO] EMC signal output Tim Goldstein 2001-05-08 14:08:07 UTC RE: [CAD_CAM_EDM_DRO] EMC signal output Jon Elson 2001-05-08 15:54:58 UTC Re: [CAD_CAM_EDM_DRO] EMC signal output Jon Elson 2001-05-08 23:33:01 UTC Re: [CAD_CAM_EDM_DRO] EMC signal output Jon Elson 2001-05-08 23:39:23 UTC Re: [CAD_CAM_EDM_DRO] EMC signal output Cryo 2001-05-09 05:17:59 UTC Re[2]: [CAD_CAM_EDM_DRO] EMC signal output Jon Elson 2001-05-09 08:26:49 UTC Re: [CAD_CAM_EDM_DRO] EMC signal output Tim Goldstein 2001-05-09 09:08:21 UTC RE: [CAD_CAM_EDM_DRO] EMC signal output ballendo@y... 2001-05-10 03:29:20 UTC Re: EMC signal output Jon Elson 2001-05-13 23:26:16 UTC Re: [CAD_CAM_EDM_DRO] EMC signal output