Re: Transformer wiring hookup 110/220
Posted by
turbulatordude <davemucha@j...
on 2003-01-17 07:11:24 UTC
A word of caution is to power them with your voltage and no load
whatsoevr. just test output with a meter. it would be terrible to
get twice the output on your caps.
--- In CAD_CAM_EDM_DRO@yahoogroups.com, "Tim Goldstein" <timg@k...>
wrote:
whatsoevr. just test output with a meter. it would be terrible to
get twice the output on your caps.
--- In CAD_CAM_EDM_DRO@yahoogroups.com, "Tim Goldstein" <timg@k...>
wrote:
> You wired it properly the first time. There is only one primarythat has
> multiple taps. Just tape off one red and get on with your CNCproduct=7846+TR)
> conversion.
>
> Tim
> [Denver, CO]
> Sherline products at Deep Discount
> Mach1 & DeskCNC with credit card ordering
> www.KTMarketing.com/Sherline
>
> > -----Original Message-----
> >
> > I received my transformers today!!!
> > I went to wire them up and had to stop to think about how to wire
> > them.
> > The transformers are (http://www.mpja.com/product.asp?
> > I hook the blues up for 24V, no problemreds,
> > The primary is what is confussing me.
> > There are 2 red wires and one black.
> > the label on top shows as follows
> > RED 110V| |BLUE 12V
> > | |
> > Black | |Yellow
> > | |
> > RED 220V| |BLUE 12v
> >
> > I would assume if you were using a 220V you would just wire the
> > and leave the center black disconnected.other
> > but what about 110V? I Hooke one red and the black.
> > and bingo 24V across the blues.
> > I started to think about this and though but I don't have the
> > half of the primary hooked up.
> > So I wired the other red to the first red.
> > The transformer hummed for a second, then tripped the reset on my
> > power strip.
> > How do I wire for both primarys to power up?
> >
> >
> > Jerry
Discussion Thread
fozzyber <jerry@o...
2003-01-16 22:54:09 UTC
Transformer wiring hookup 110/220
Tim Goldstein
2003-01-16 23:46:47 UTC
RE: [CAD_CAM_EDM_DRO] Transformer wiring hookup 110/220
turbulatordude <davemucha@j...
2003-01-17 07:11:24 UTC
Re: Transformer wiring hookup 110/220
Bernard R <bwjarandall@c...
2003-01-17 07:41:58 UTC
Re: Transformer wiring hookup 110/220
j.guenther
2003-01-17 07:55:46 UTC
RE: [CAD_CAM_EDM_DRO] Re: Transformer wiring hookup 110/220
fozzyber <jerry@o...
2003-01-17 07:58:49 UTC
Re: Transformer wiring hookup 110/220
j.guenther
2003-01-17 08:03:50 UTC
RE: [CAD_CAM_EDM_DRO] Re: Transformer wiring hookup 110/220
fozzyber <jerry@o...
2003-01-17 08:27:02 UTC
Re: Transformer wiring hookup 110/220
Bernard R <bwjarandall@c...
2003-01-17 08:31:23 UTC
Re: Transformer wiring hookup 110/220
Tim Goldstein
2003-01-17 09:44:40 UTC
RE: [CAD_CAM_EDM_DRO] Re: Transformer wiring hookup 110/220
fozzyber <jerry@o...
2003-01-17 09:59:22 UTC
Re: Transformer wiring hookup 110/220
C.S. Mo
2003-01-17 12:50:29 UTC
CAM Software & DXF
Dave Lantz
2003-01-17 12:54:47 UTC
RE: [CAD_CAM_EDM_DRO] CAM Software & DXF
Tim Goldstein
2003-01-17 13:01:52 UTC
RE: [CAD_CAM_EDM_DRO] CAM Software & DXF
j.guenther
2003-01-17 13:01:56 UTC
RE: [CAD_CAM_EDM_DRO] CAM Software & DXF
doug98105 <dougrasmussen@c...
2003-01-17 13:07:25 UTC
Re: CAM Software & DXF
C.S. Mo
2003-01-17 13:12:21 UTC
RE: [CAD_CAM_EDM_DRO] CAM Software & DXF
ballendo <ballendo@y...
2003-01-17 20:55:09 UTC
Re: Transformer wiring hookup 110/220