The 75V is too high. multiply output by 1.414 to obtain the DC
voltage you would wind up with.

Dave


--- In CAD_CAM_EDM_DRO@yahoogroups.com, Marv Frankel <dcdziner@p...>
wrote:
> Les,
> I've been following this thread with interest, and asked the
> originator for a schematic, using two of the 24V transformers. I
also looked
> into the www.mpja.com web site, and saw a 48V @ 10A, and a 75V @
6.6A
> available, but at a much greater cost. Would mounting 4 or 6 of the
24V
> units in one case require a fair amount of ventilation, or wouldn't
there be
> that much heat generated?
>
> Marv Frankel
> Los Angeles
>
> ----- Original Message -----
> From: "Les Watts" <leswatts@a...>
> To: <CAD_CAM_EDM_DRO@yahoogroups.com>
> Sent: Sunday, January 19, 2003 8:57 AM
> Subject: [CAD_CAM_EDM_DRO] power supplies form those 24v
transformers
>
>
> > Some of my customers from the list have asked about
> > powers supplies for servos/amps. This concerns higher
> > voltage for the larger Bridgeport conversion type motors.
> >
> > I want to help my customers on this, but I want to
> > do it on list so others can help or use the information.
> >
> > Now, there was a thread about the economical 24v 10a
> > transformers. I have looked into a supply using four of
> > these for a nominal 66v 20a or six giving 66v 30a.
> >
> > But I think there is a problem with these. You see,
> > line voltages are speced a little differently in various
> > countries.
> >
> > The primary of these is listed as 110vac I think.
> >
> > We want a higher voltage supply, but some margin
> > away from an amplifiers maximum input voltage must
> > be allowed. This give some latitude for things like
> > normal line voltage variations, surges from nearby
> > equipment, and servo regenerative braking.
> >
> > So, considering using two of the 24v secondaries in series
> > we may get
> >
> > 48 vac
> >
> > x 117/110 (our nominal US line voltage)
> >
> > x1.1 (+10% normal line variation)
> >
> > x1.414 (after rectification and filtering)
> >
> > -1.4 (the forward voltage drops of the rectifiers)
> > = 78vdc
> >
> > I think this is a little too close to the Gecko 80v max input.
> > I talked with Mariss about this some, and he needs to have
> > the last word on this as they are his amps.
> >
> > If you are using something like Copley 412, 78v is fine.
> >
> > I suspect these transformers give 24v at 110, but our line
voltages
> > are often 120+. The power companies like to run high to sell more
> > power with less I^2R on their lines.
> >
> > Didn't someone measure higher open circuit voltages on these
things?
> >
> > So I am not going to recommend using the transformers in this way.
> > But if someone has some in hand and can ACCURATELY measure the
> > transformer output and line using the 220v primary and 240v line I
> > would like to know. Tim?
> >
> > Why 240? The KVA of a 30 amp supply is kind of pushing it for a
> > standard 120v 15a line considering surges.
> >
> > If the 24v transformers put out 24 with 120 or 240 in that
> > would yield a much more reasonable 73.5vdc max, 66v nominal.
> > But I don't think they do. It would be nice ,though, as they are a
> bargain.
> >
> > If they are to high, there are lots of other options. One
> > is Doug Fortune's Monster supply at
> > http://www.cncKITS.com
> >
> > Another is the toroidal power transformer kit at
> > http://www.toroid.com
> > They supply a 1.5 KVA toroid core with a pre-wired primary,
> > and you wind your own custom secondary.
> >
> > A further option is a snubber, higher current bleeder resistor,
> > or diodes.
> >
> > But I would like to see exactly what these transformers put out.
> >
> > Les
> >
> >
> > Leslie Watts
> > L M Watts Furniture
> > Tiger, Georgia USA
> > http://www.alltel.net/~leswatts/wattsfurniturewp.html
> > engineering page:
> > http://www.alltel.net/~leswatts/shop.html
> > Surplus cnc for sale:
> > http://www.alltel.net/~leswatts/forsale.html
> >
> >
> > Addresses:
> > FAQ: http://www.ktmarketing.com/faq.html
> > FILES: http://groups.yahoo.com/group/CAD_CAM_EDM_DRO/files/
> > Post Messages: CAD_CAM_EDM_DRO@yahoogroups.com
> >
> > Subscribe: CAD_CAM_EDM_DRO-subscribe@yahoogroups.com
> > Unsubscribe: CAD_CAM_EDM_DRO-unsubscribe@yahoogroups.com
> > List owner: CAD_CAM_EDM_DRO-owner@yahoogroups.com, wanliker@a...
> > Moderator: jmelson@a... timg@k... [Moderator]
> > URL to this group: http://groups.yahoo.com/group/CAD_CAM_EDM_DRO
> >
> > OFF Topic POSTS: General Machining
> > If you wish to post on unlimited OT subjects goto:
> aol://5863:126/rec.crafts.metalworking or go thru Google.com to
reach it if
> you have trouble.
> > http://www.metalworking.com/news_servers.html
> >
> > http://groups.yahoo.com/group/jobshophomeshop I consider this
to be a
> sister site to the CCED group, as many of the same members are
there, for OT
> subjects, that are not allowed on the CCED list.
> >
> > NOTICE: ALL POSTINGS TO THIS GROUP BECOME PUBLIC DOMAIN BY
POSTING THEM.
> DON'T POST IF YOU CAN NOT ACCEPT THIS.....NO EXCEPTIONS........
> > bill
> > List Mom
> > List Owner
> >
> >
> >
> > Your use of Yahoo! Groups is subject to
http://docs.yahoo.com/info/terms/
> >
> >
> >

Discussion Thread

Les Watts 2003-01-19 08:53:43 UTC power supplies form those 24v transformers Marv Frankel 2003-01-19 10:00:34 UTC Re: [CAD_CAM_EDM_DRO] power supplies form those 24v transformers Les Watts 2003-01-19 10:22:45 UTC Re: [CAD_CAM_EDM_DRO] power supplies form those 24v transformers turbulatordude <davemucha@j... 2003-01-19 11:58:33 UTC Re: power supplies form those 24v transformers Marv Frankel 2003-01-19 13:23:10 UTC Re: [CAD_CAM_EDM_DRO] power supplies form those 24v transformers Les Watts 2003-01-19 14:00:03 UTC Re: [CAD_CAM_EDM_DRO] power supplies form those 24v transformers fozzyber <jerry@o... 2003-01-19 14:43:22 UTC Re: power supplies form those 24v transformers Les Watts 2003-01-19 15:24:03 UTC Re: [CAD_CAM_EDM_DRO] Re: power supplies form those 24v transformers mayfieldtm <mayfiet@i... 2003-01-19 16:43:39 UTC Re: power supplies form those 24v transformers Vince Negrete 2003-01-19 16:52:02 UTC Re: [CAD_CAM_EDM_DRO] Re: power supplies form those 24v transformers fozzyber <jerry@o... 2003-01-19 17:13:05 UTC Re: power supplies form those 24v transformers Les Watts 2003-01-20 04:45:32 UTC Re: [CAD_CAM_EDM_DRO] Re: power supplies form those 24v transformers Jerry Moreau 2003-01-20 06:39:49 UTC RE: [CAD_CAM_EDM_DRO] Re: power supplies form those 24v transformers ballendo <ballendo@y... 2003-01-22 05:42:50 UTC Inrush and prevention? was Re: power supplies form those 24v transformers ballendo <ballendo@y... 2003-01-22 05:51:51 UTC Re: power supplies from those 24v transformers ballendo <ballendo@y... 2003-01-22 06:39:34 UTC Re: power supplies form those 24v transformers Bernard R <bwjarandall@c... 2003-01-22 06:52:20 UTC Re: power supplies form those 24v transformers Les Watts 2003-01-22 07:24:12 UTC Re: [CAD_CAM_EDM_DRO] Inrush and prevention? was Re: power supplies form those 24v transformers Jon Elson 2003-01-22 09:52:50 UTC Re: [CAD_CAM_EDM_DRO] Inrush and prevention? was Re: power supplies form those 24v transformers Lee Studley <indigo_red@q... 2003-01-22 12:45:42 UTC Inrush and prevention? was Re: power supplies form those 24v transformers