RF Shielding - was Re: Router spindle electrical noise.
Posted by
c_holm10017
on 2003-10-20 14:26:47 UTC
I have been chasing similar RF interference problems with my CNC
conversion Sherline, and wonder whether anyone has a source of braid
to put over cables? I spent some time making my cables, and would
prefer to put a shield over them, rather than re-doing them. (the
aluminum foil seems to help but it looks terrible and is very
fragile.)
If not, any place that has reasonably priced 4 conductor braid
shielded cable with wires bigger than 22 gage?
Thanks in advance.
Chris
conversion Sherline, and wonder whether anyone has a source of braid
to put over cables? I spent some time making my cables, and would
prefer to put a shield over them, rather than re-doing them. (the
aluminum foil seems to help but it looks terrible and is very
fragile.)
If not, any place that has reasonably priced 4 conductor braid
shielded cable with wires bigger than 22 gage?
Thanks in advance.
Chris
--- In CAD_CAM_EDM_DRO@yahoogroups.com, cnc002@a... wrote:
> In a message dated 10/20/2003 12:30:14 PM Eastern Daylight Time,
> cncman172@y... writes:
>
> > Jon,
> >
> > I had the very same problem and I resolved it by replacing the
cable
> > on my limit and home switches with braid shielded cable. Make
sure
> > you only ground the shield to the end that attaches to the
controller
> > and leave it ungrounded at the switch or sensor end. As soon as
I
> > made these changes all my limit and home switch problems
vanished...
> > amazing...
> >
> > Russ
> >
>
> Russ:
>
> You found the proper way to handle the interference problems that
usually
> occur with DC voltage signals on machines that also have AC
voltage. The only
> thing I might add is that if using just braided shielded cable
doesn't totally
> correct the problems, you can use a shielded twisted pair cable and
that will
> often resolve the remaining problems.
>
> Randy Abernathy
>
>
> [Non-text portions of this message have been removed]
Discussion Thread
balsaman_cnc
2003-10-19 09:26:33 UTC
Router spindle electrical noise.
Lee Studley
2003-10-19 13:32:37 UTC
Re: Router spindle electrical noise.
Dan
2003-10-19 17:03:56 UTC
Re: [CAD_CAM_EDM_DRO] Router spindle electrical noise.
John Johnson
2003-10-19 17:04:48 UTC
Re: [CAD_CAM_EDM_DRO] Router spindle electrical noise.
Jon Elson
2003-10-19 22:12:44 UTC
Re: [CAD_CAM_EDM_DRO] Router spindle electrical noise.
Superonline
2003-10-20 07:53:46 UTC
Re: [CAD_CAM_EDM_DRO] Router spindle electrical noise.
Carl Mikkelsen
2003-10-20 08:57:13 UTC
Re: [CAD_CAM_EDM_DRO] Router spindle electrical noise.
cncman172
2003-10-20 09:27:16 UTC
Re: Router spindle electrical noise.
cnc002@a...
2003-10-20 11:00:26 UTC
Re: [CAD_CAM_EDM_DRO] Re: Router spindle electrical noise.
c_holm10017
2003-10-20 14:26:47 UTC
RF Shielding - was Re: Router spindle electrical noise.
Paul
2003-10-20 15:22:02 UTC
Re: [CAD_CAM_EDM_DRO] RF Shielding - was Re: Router spindle electrical noise.
balsaman_cnc
2003-10-20 20:42:26 UTC
Re: Router spindle electrical noise.
jimalb2309
2003-10-20 20:42:47 UTC
RF Shielding - was Re: Router spindle electrical noise.
Chris Cowley
2003-10-21 07:40:25 UTC
Re: [CAD_CAM_EDM_DRO] RF Shielding - was Re: Router spindle electrical noise.
Dan Peirce
2003-10-21 07:41:58 UTC
Re: [CAD_CAM_EDM_DRO] Re: Router spindle electrical noise.
balsaman_cnc
2003-10-21 09:35:02 UTC
Re: Router spindle electrical noise.
balsaman_cnc
2003-10-22 08:16:28 UTC
Re: Router spindle electrical noise. SOLVED