Re: 3 Phase rotary converters
Posted by
cnc_4_me
on 2005-05-08 17:21:18 UTC
> Does anybody know for sure about the voltage rating of capacitors?I think that is a peak rating. Peak is 1.414 x 240vac = 340 volts
> I read someplace that the voltage printed on the capacitors is not
> the voltage that they should be operated at on a rotary convertor.
> A capacitor for a 220 VAC rotary convertor should have approx
> 370 volts printed on its case. ???????
>
> Bob McKnight
peak. This gives a 30 volt safey factor. I used 240v because this
is what the lines are supposed to be.
Wally
--- In CAD_CAM_EDM_DRO@yahoogroups.com, bobmcknight@c... wrote:
> I am running a rather large motor (10 Hp) and decided
> that the easiest way to start it was to mount a 1/2 hp
> motor and belt connect it to the rotary convertor. To
> start, I turn on the 110v 1/2 hp motor and tighten the
> sliping belt with a handle on the idler pulley. This only
> takes a few seconds. When the rotary motor comes
> up to speed, I release the handle and the belt slips.
> then I switch on the single phase power to rotary convertor
> and it goes on its merry way. No high starting current, or
> prolonged waits for the convetor to come up to speed.
> I just have the run capacitors to the third leg. I could deal
> with the mechanical starte a lot easier than going thru all
> design and experimentation. I use it to run a 300 amp MIG
> welder which will never see close to that output, but it was
> dirt cheap and in excellent condition. I also have a 17" lathe
> that can use either a static or rotary convertor, and a 10 grinder.
> So if you have a small electric service to your shop and don't
> want to dim the lights while starting the convertor, there is an
> alternative.
>
> Does anybody know for sure about the voltage rating of capacitors?
> I read someplace that the voltage printed on the capacitors is not
> the voltage that they should be operated at on a rotary convertor.
> A capacitor for a 220 VAC rotary convertor should have approx
> 370 volts printed on its case. ???????
>
> Bob McKnight
Discussion Thread
Andrey Lipavsky
2005-05-08 05:31:48 UTC
Optical limit switches
Lance Hopper
2005-05-08 05:49:21 UTC
Re: Optical limit switches
turbulatordude
2005-05-08 06:02:32 UTC
Re: Optical limit switches
Andrey Lipavsky
2005-05-08 06:08:30 UTC
RE: [CAD_CAM_EDM_DRO] Re: Optical limit switches
David Speck
2005-05-08 07:24:22 UTC
Re: [CAD_CAM_EDM_DRO] Re: Optical limit switches
turbulatordude
2005-05-08 07:57:00 UTC
Re: Optical limit switches
David Speck
2005-05-08 09:28:31 UTC
3 Phase rotary converters
cnc_4_me
2005-05-08 09:57:47 UTC
Re: 3 Phase rotary converters
David Speck
2005-05-08 10:22:38 UTC
Re: [CAD_CAM_EDM_DRO] Re: 3 Phase rotary converters
Beau Beaufait
2005-05-08 15:08:57 UTC
Re: [CAD_CAM_EDM_DRO] 3 Phase rotary converters
Beau Beaufait
2005-05-08 15:09:07 UTC
Re: [CAD_CAM_EDM_DRO] Re: 3 Phase rotary converters
bobmcknight@c...
2005-05-08 16:45:30 UTC
Re: [CAD_CAM_EDM_DRO] 3 Phase rotary converters
cnc_4_me
2005-05-08 17:21:18 UTC
Re: 3 Phase rotary converters
JanRwl@A...
2005-05-08 21:10:24 UTC
Re: [CAD_CAM_EDM_DRO] 3 Phase rotary converters
cnc002@a...
2005-05-09 06:09:56 UTC
Re: [CAD_CAM_EDM_DRO] Re: 3 Phase rotary converters
bobmcknight@c...
2005-05-09 19:38:48 UTC
Re: [CAD_CAM_EDM_DRO] Re: 3 Phase rotary converters
Arturo E. Duncan
2005-05-09 19:39:45 UTC
Re: Optical limit switches
Rick
2005-05-09 21:46:39 UTC
Re: [CAD_CAM_EDM_DRO] Re: 3 Phase rotary converters
turbulatordude
2005-05-09 22:15:09 UTC
Re: Optical limit switches
Beau Beaufait
2005-05-09 22:37:34 UTC
Re: [CAD_CAM_EDM_DRO] 3 Phase rotary converters
Doug M
2005-05-10 06:21:14 UTC
Re: 3 Phase rotary converters
Greg Jackson
2005-09-20 20:33:16 UTC
RE: [CAD_CAM_EDM_DRO] 3 Phase rotary converters
JanRwl@A...
2005-09-20 21:08:10 UTC
Re: [CAD_CAM_EDM_DRO] 3 Phase rotary converters