Re: Question:Parallel interface with Gecko 201 drivers
Posted by
Kayla Sanders
on 2002-10-11 21:51:15 UTC
I hope that I dont have aproblem with RFI. But in the case that I
do, I just want to be prepared.I see nothing wrong with that.
Im here to LEARN, as most people are. And I still have unanswered
questions that Im hoping that someone will help me with.
Is anyone willing to answer these questions the best that they can??
Preferrably without the sarcasm.
Thanks
do, I just want to be prepared.I see nothing wrong with that.
Im here to LEARN, as most people are. And I still have unanswered
questions that Im hoping that someone will help me with.
Is anyone willing to answer these questions the best that they can??
Preferrably without the sarcasm.
Thanks
--- In CAD_CAM_EDM_DRO@y..., "Tim Goldstein" <timg@k...> wrote:
> Glad you have not gotten around my machines to tell them how their
wires
> must me. The parallel cables I have used and the ones I have cut
apart
> (cheapest I can find in both cases) are not twisted pair at all.
>
> You are taking some best practices guidelines and solid solutions
IF you
> have noise problems and trying to make it the requirements for
wiring.
> In most cases it just ain't that critical.
>
> Tim
> [Denver, CO]
>
>
> > -----Original Message-----
> > While using a breakout board is probably the best way to go, i
find
> > myself wanting to make my own cable for the pure satisfaction of
it
> > and the learning experience..
> > Heres what i know about cabling from parallel port.....
> > The wires must be in twisted pairs.
> > The step/dir wires must not be in the same twisted pair.
> > The length should be no more than 12 feet in length.
> > Any power derived from the controller source must be seperate
from
> > the step/ dir wires. Prefferably as far away as possible.
> > The wires must be of a shielded kind.
> >
> > My question is this....
> > If the step/dir wires can not be put in the same twisted pair,
then
> > what should a twisted pair consist of?
> > Two step in a pair or two dir in a pair? Or what?
> > If you were to make your own cable(eveen though you probably
would
> > opt not top do so) How would arrange the wires??
> >
> > Thanks again
Discussion Thread
Kayla Sanders
2002-10-11 08:08:46 UTC
Question:Parallel interface with Gecko 201 drivers
Tim Goldstein
2002-10-11 09:37:58 UTC
Re: [CAD_CAM_EDM_DRO] Question:Parallel interface with Gecko 201 drivers
Kayla Sanders
2002-10-11 21:10:11 UTC
Re: Question:Parallel interface with Gecko 201 drivers
Kayla Sanders
2002-10-11 21:14:14 UTC
Re: Question:Parallel interface with Gecko 201 drivers
Kayla Sanders
2002-10-11 21:18:18 UTC
Re: Question:Parallel interface with Gecko 201 drivers
Tim Goldstein
2002-10-11 21:25:23 UTC
RE: [CAD_CAM_EDM_DRO] Re: Question:Parallel interface with Gecko 201 drivers
Kayla Sanders
2002-10-11 21:51:15 UTC
Re: Question:Parallel interface with Gecko 201 drivers
Raymond Heckert
2002-10-11 22:04:00 UTC
Re: [CAD_CAM_EDM_DRO] Re: Question:Parallel interface with Gecko 201 drivers
Tony Jeffree
2002-10-12 03:43:20 UTC
Re: Question:Parallel interface with Gecko 201 drivers
Alan Marconett KM6VV
2002-10-12 10:24:19 UTC
Re: Question:Parallel interface with Gecko 201 drivers
jagco1998
2002-10-12 15:34:32 UTC
Re: Question:Parallel interface with Gecko 201 drivers
Alan Marconett KM6VV
2002-10-12 16:32:54 UTC
Re: Question:Parallel interface with Gecko 201 drivers
Jim Brown
2002-10-12 17:26:45 UTC
Re: [CAD_CAM_EDM_DRO] Re: Question:Parallel interface with Gecko 201 drivers
MIKEC@W...
2002-10-12 20:43:04 UTC
Re: [CAD_CAM_EDM_DRO] Re: Question:Parallel interface with Gecko 201 drivers
Tim Goldstein
2002-10-12 21:05:07 UTC
RE: [CAD_CAM_EDM_DRO] Re: Question:Parallel interface with Gecko 201 drivers
Alan Marconett KM6VV
2002-10-13 00:32:40 UTC
Re: Question:Parallel interface with Gecko 201 drivers
turbulatordude
2002-10-13 06:16:37 UTC
Re: Question:Parallel interface with Gecko 201 drivers
Jim Brown
2002-10-13 10:25:59 UTC
Re: [CAD_CAM_EDM_DRO] Re: Question:Parallel interface with Gecko 201 drivers