Hi Kayla,

In an ideal printer cable, the control and data lines would EACH have
their own pair, the "other" wires being grounds. Initially, you should
be fine with a standard parallel cable. Just insure that it has all 25
conductors! Some cables are designed on the cheap for serial, and don't
have all of 'em. Use a breakout box at the Gecko end, or as I did, a
connector with removable contacts, which is wired into the driver/ps box
(I posted ix, driverP). So, you don't NEED to make up a cable at all!

Alan KM6VV

Kayla Sanders wrote:
>
> I hope that I dont have aproblem with RFI. But in the case that I
> do, I just want to be prepared.I see nothing wrong with that.
> Im here to LEARN, as most people are. And I still have unanswered
> questions that Im hoping that someone will help me with.
> Is anyone willing to answer these questions the best that they can??
> Preferrably without the sarcasm.
>
> Thanks
>
> --- In CAD_CAM_EDM_DRO@y..., "Tim Goldstein" <timg@k...> wrote:
> > Glad you have not gotten around my machines to tell them how their
> wires
> > must me. The parallel cables I have used and the ones I have cut
> apart
> > (cheapest I can find in both cases) are not twisted pair at all.
> >
> > You are taking some best practices guidelines and solid solutions
> IF you
> > have noise problems and trying to make it the requirements for
> wiring.
> > In most cases it just ain't that critical.
> >
> > Tim
> > [Denver, CO]
> >
> >
> > > -----Original Message-----
> > > While using a breakout board is probably the best way to go, i
> find
> > > myself wanting to make my own cable for the pure satisfaction of
> it
> > > and the learning experience..
> > > Heres what i know about cabling from parallel port.....
> > > The wires must be in twisted pairs.
> > > The step/dir wires must not be in the same twisted pair.
> > > The length should be no more than 12 feet in length.
> > > Any power derived from the controller source must be seperate
> from
> > > the step/ dir wires. Prefferably as far away as possible.
> > > The wires must be of a shielded kind.
> > >
> > > My question is this....
> > > If the step/dir wires can not be put in the same twisted pair,
> then
> > > what should a twisted pair consist of?
> > > Two step in a pair or two dir in a pair? Or what?
> > > If you were to make your own cable(eveen though you probably
> would
> > > opt not top do so) How would arrange the wires??
> > >
> > > Thanks again
>
> Addresses:
> FAQ: http://www.ktmarketing.com/faq.html
> FILES: http://groups.yahoo.com/group/CAD_CAM_EDM_DRO/files/
>
> OFF Topic POSTS: General Machining
> If you wish to post on unlimited OT subjects goto: aol://5863:126/rec.crafts.metalworking or go thru Google.com to reach it if you have trouble.
> http://www.metalworking.com/news_servers.html
>
> http://groups.yahoo.com/group/jobshophomeshop I consider this as a sister site to the CCED group, as many of the same members are there, for OT subjects, that are not allowed on the CCED list.
>
> NOTICE: ALL POSTINGS TO THIS GROUP BECOME PUBLIC DOMAIN BY POSTING THEM. DON'T POST IF YOU CAN NOT ACCEPT THIS.....NO EXCEPTIONS........
>
> Post messages: CAD_CAM_EDM_DRO@yahoogroups.com
> Subscribe: CAD_CAM_EDM_DRO-subscribe@yahoogroups.com
> Unsubscribe: CAD_CAM_EDM_DRO-unsubscribe@yahoogroups.com
> List owner: CAD_CAM_EDM_DRO-owner@yahoogroups.com, wanliker@...
> Moderator: jmelson@... timg@... [Moderator]
> URL to this group: http://groups.yahoo.com/group/CAD_CAM_EDM_DRO
> bill,
> List Mom
> List Owner
>
>
>
> Your use of Yahoo! Groups is subject to http://docs.yahoo.com/info/terms/

Discussion Thread

Kayla Sanders 2002-10-11 08:08:46 UTC Question:Parallel interface with Gecko 201 drivers Tim Goldstein 2002-10-11 09:37:58 UTC Re: [CAD_CAM_EDM_DRO] Question:Parallel interface with Gecko 201 drivers Kayla Sanders 2002-10-11 21:10:11 UTC Re: Question:Parallel interface with Gecko 201 drivers Kayla Sanders 2002-10-11 21:14:14 UTC Re: Question:Parallel interface with Gecko 201 drivers Kayla Sanders 2002-10-11 21:18:18 UTC Re: Question:Parallel interface with Gecko 201 drivers Tim Goldstein 2002-10-11 21:25:23 UTC RE: [CAD_CAM_EDM_DRO] Re: Question:Parallel interface with Gecko 201 drivers Kayla Sanders 2002-10-11 21:51:15 UTC Re: Question:Parallel interface with Gecko 201 drivers Raymond Heckert 2002-10-11 22:04:00 UTC Re: [CAD_CAM_EDM_DRO] Re: Question:Parallel interface with Gecko 201 drivers Tony Jeffree 2002-10-12 03:43:20 UTC Re: Question:Parallel interface with Gecko 201 drivers Alan Marconett KM6VV 2002-10-12 10:24:19 UTC Re: Question:Parallel interface with Gecko 201 drivers jagco1998 2002-10-12 15:34:32 UTC Re: Question:Parallel interface with Gecko 201 drivers Alan Marconett KM6VV 2002-10-12 16:32:54 UTC Re: Question:Parallel interface with Gecko 201 drivers Jim Brown 2002-10-12 17:26:45 UTC Re: [CAD_CAM_EDM_DRO] Re: Question:Parallel interface with Gecko 201 drivers MIKEC@W... 2002-10-12 20:43:04 UTC Re: [CAD_CAM_EDM_DRO] Re: Question:Parallel interface with Gecko 201 drivers Tim Goldstein 2002-10-12 21:05:07 UTC RE: [CAD_CAM_EDM_DRO] Re: Question:Parallel interface with Gecko 201 drivers Alan Marconett KM6VV 2002-10-13 00:32:40 UTC Re: Question:Parallel interface with Gecko 201 drivers turbulatordude 2002-10-13 06:16:37 UTC Re: Question:Parallel interface with Gecko 201 drivers Jim Brown 2002-10-13 10:25:59 UTC Re: [CAD_CAM_EDM_DRO] Re: Question:Parallel interface with Gecko 201 drivers