RE: [CAD_CAM_EDM_DRO] Parallel Port to Power Supply Grounding Differential
Posted by
Tim Goldstein
on 2003-07-07 23:08:19 UTC
> If you have the Gecko drives that can only work with aThe G201 & G320 drives are +5V common only. The G210 & G340 can be
> negative common
> terminal,
> then that common should be connected to the parallel port's
> ground. You
> will
> likely need pull-up resistors from the step and direction
> signals to a
> +5 V derived
> from the computer as above.
configured with jumpers to either +5V common or negative (ground)
common. I have used them with ground common on a number of systems and
never needed a pull up resistor.
Tim
[Denver, CO]
Sherline & Taig products at Deep Discount
Mach1 & DeskCNC with credit card ordering
www.KTMarketing.com/Sherline
e-mail me at Timg @ KTMarketing.com for items not yet listed
Discussion Thread
Bill Kichman
2003-07-07 18:58:24 UTC
Parallel Port to Power Supply Grounding Differential
int3man
2003-07-07 21:48:51 UTC
Re: Parallel Port to Power Supply Grounding Differential
Jon Elson
2003-07-07 22:07:32 UTC
Re: [CAD_CAM_EDM_DRO] Parallel Port to Power Supply Grounding Differential
Tim Goldstein
2003-07-07 23:08:19 UTC
RE: [CAD_CAM_EDM_DRO] Parallel Port to Power Supply Grounding Differential
Bill Kichman
2003-07-08 05:47:27 UTC
Re: [CAD_CAM_EDM_DRO] Parallel Port to Power Supply Grounding Differential
turbulatordude
2003-07-08 07:16:07 UTC
Re: Parallel Port to Power Supply Grounding Differential
Jon Elson
2003-07-08 09:28:38 UTC
Re: [CAD_CAM_EDM_DRO] Parallel Port to Power Supply Grounding Differential
JanRwl@A...
2003-07-08 09:52:52 UTC
Re: [CAD_CAM_EDM_DRO] Parallel Port to Power Supply Grounding Differential
Rob WHITE
2003-07-08 09:59:44 UTC
has anyone added a CNC system to this mill
Don Rogers
2003-07-08 10:08:48 UTC
Re: Parallel Port to Power Supply Grounding Differential
JanRwl@A...
2003-07-08 10:15:13 UTC
Re: [CAD_CAM_EDM_DRO] Re: Parallel Port to Power Supply Grounding Differential
Bill Kichman
2003-07-08 10:39:06 UTC
Re: [CAD_CAM_EDM_DRO] Parallel Port to Power Supply Grounding Differential
washcomp
2003-07-08 10:43:33 UTC
Re: Parallel Port to Power Supply Grounding Differential
Kim Lux
2003-07-08 11:12:47 UTC
Gecko 320 heatsink requirements: needed ?
Kim Lux
2003-07-08 11:29:18 UTC
5C collet closer drawbar threading problem
Kim Lux
2003-07-08 11:48:44 UTC
Re: [CAD_CAM_EDM_DRO] 5C collet closer drawbar threading problem
Weyland
2003-07-08 13:55:57 UTC
Re: [CAD_CAM_EDM_DRO] 5C collet closer drawbar threading problem
doug98105
2003-07-08 14:20:51 UTC
Re: 5C collet closer drawbar threading problem
Kim Lux
2003-07-08 14:53:52 UTC
Re: [CAD_CAM_EDM_DRO] Re: 5C collet closer drawbar threading problem
Vince Negrete
2003-07-08 16:52:48 UTC
Re: [CAD_CAM_EDM_DRO] Re: Parallel Port to Power Supply Grounding Differential
Jon Elson
2003-07-08 21:48:03 UTC
Re: [CAD_CAM_EDM_DRO] Gecko 320 heatsink requirements: needed ?
Jon Elson
2003-07-08 21:53:56 UTC
Re: [CAD_CAM_EDM_DRO] 5C collet closer drawbar threading problem
Kim Lux
2003-07-08 22:59:09 UTC
Re: [CAD_CAM_EDM_DRO] 5C collet closer drawbar threading problem