RE: [CAD_CAM_EDM_DRO] Parallel Port to Power Supply Grounding Differential

Posted by Tim Goldstein
on 2003-07-07 23:08:19 UTC
> If you have the Gecko drives that can only work with a
> negative common
> terminal,
> then that common should be connected to the parallel port's
> ground. You
> will
> likely need pull-up resistors from the step and direction
> signals to a
> +5 V derived
> from the computer as above.

The G201 & G320 drives are +5V common only. The G210 & G340 can be
configured with jumpers to either +5V common or negative (ground)
common. I have used them with ground common on a number of systems and
never needed a pull up resistor.

Tim
[Denver, CO]
Sherline & Taig products at Deep Discount
Mach1 & DeskCNC with credit card ordering
www.KTMarketing.com/Sherline
e-mail me at Timg @ KTMarketing.com for items not yet listed

Discussion Thread

Bill Kichman 2003-07-07 18:58:24 UTC Parallel Port to Power Supply Grounding Differential int3man 2003-07-07 21:48:51 UTC Re: Parallel Port to Power Supply Grounding Differential Jon Elson 2003-07-07 22:07:32 UTC Re: [CAD_CAM_EDM_DRO] Parallel Port to Power Supply Grounding Differential Tim Goldstein 2003-07-07 23:08:19 UTC RE: [CAD_CAM_EDM_DRO] Parallel Port to Power Supply Grounding Differential Bill Kichman 2003-07-08 05:47:27 UTC Re: [CAD_CAM_EDM_DRO] Parallel Port to Power Supply Grounding Differential turbulatordude 2003-07-08 07:16:07 UTC Re: Parallel Port to Power Supply Grounding Differential Jon Elson 2003-07-08 09:28:38 UTC Re: [CAD_CAM_EDM_DRO] Parallel Port to Power Supply Grounding Differential JanRwl@A... 2003-07-08 09:52:52 UTC Re: [CAD_CAM_EDM_DRO] Parallel Port to Power Supply Grounding Differential Rob WHITE 2003-07-08 09:59:44 UTC has anyone added a CNC system to this mill Don Rogers 2003-07-08 10:08:48 UTC Re: Parallel Port to Power Supply Grounding Differential JanRwl@A... 2003-07-08 10:15:13 UTC Re: [CAD_CAM_EDM_DRO] Re: Parallel Port to Power Supply Grounding Differential Bill Kichman 2003-07-08 10:39:06 UTC Re: [CAD_CAM_EDM_DRO] Parallel Port to Power Supply Grounding Differential washcomp 2003-07-08 10:43:33 UTC Re: Parallel Port to Power Supply Grounding Differential Kim Lux 2003-07-08 11:12:47 UTC Gecko 320 heatsink requirements: needed ? Kim Lux 2003-07-08 11:29:18 UTC 5C collet closer drawbar threading problem Kim Lux 2003-07-08 11:48:44 UTC Re: [CAD_CAM_EDM_DRO] 5C collet closer drawbar threading problem Weyland 2003-07-08 13:55:57 UTC Re: [CAD_CAM_EDM_DRO] 5C collet closer drawbar threading problem doug98105 2003-07-08 14:20:51 UTC Re: 5C collet closer drawbar threading problem Kim Lux 2003-07-08 14:53:52 UTC Re: [CAD_CAM_EDM_DRO] Re: 5C collet closer drawbar threading problem Vince Negrete 2003-07-08 16:52:48 UTC Re: [CAD_CAM_EDM_DRO] Re: Parallel Port to Power Supply Grounding Differential Jon Elson 2003-07-08 21:48:03 UTC Re: [CAD_CAM_EDM_DRO] Gecko 320 heatsink requirements: needed ? Jon Elson 2003-07-08 21:53:56 UTC Re: [CAD_CAM_EDM_DRO] 5C collet closer drawbar threading problem Kim Lux 2003-07-08 22:59:09 UTC Re: [CAD_CAM_EDM_DRO] 5C collet closer drawbar threading problem