5C collet closer drawbar threading problem

Posted by Kim Lux
on 2003-07-08 11:29:18 UTC
We are building an air operated 5C collet closer.

The drawbar we are making is machined from a piece of seamless
mechanical tubing. We've got it adjusted for zero runout.

We are cutting a 1.044" OD x 24 TPI thread on the outside of a 1.250"
piece of tubing turned down to 1.030" This will pull on the internal
thread of the collet to close it in the chuck.

We've threaded two of these drawbars now and both times the collet has
significant runout when threaded to the drawbar. Why ? The thread
seems to be high quality. The collet seems to be OK. The drawbar runs
true. Why does the collet have runout when screwed on ?

What is the solution to this problem ?

I'm tempted to cut the thread loose so that the collet can center itself
in the chuck irrespective of the drawbar position.

Any help would be appreciated. Thanks.



Kim Lux <lux@...>

Discussion Thread

Bill Kichman 2003-07-07 18:58:24 UTC Parallel Port to Power Supply Grounding Differential int3man 2003-07-07 21:48:51 UTC Re: Parallel Port to Power Supply Grounding Differential Jon Elson 2003-07-07 22:07:32 UTC Re: [CAD_CAM_EDM_DRO] Parallel Port to Power Supply Grounding Differential Tim Goldstein 2003-07-07 23:08:19 UTC RE: [CAD_CAM_EDM_DRO] Parallel Port to Power Supply Grounding Differential Bill Kichman 2003-07-08 05:47:27 UTC Re: [CAD_CAM_EDM_DRO] Parallel Port to Power Supply Grounding Differential turbulatordude 2003-07-08 07:16:07 UTC Re: Parallel Port to Power Supply Grounding Differential Jon Elson 2003-07-08 09:28:38 UTC Re: [CAD_CAM_EDM_DRO] Parallel Port to Power Supply Grounding Differential JanRwl@A... 2003-07-08 09:52:52 UTC Re: [CAD_CAM_EDM_DRO] Parallel Port to Power Supply Grounding Differential Rob WHITE 2003-07-08 09:59:44 UTC has anyone added a CNC system to this mill Don Rogers 2003-07-08 10:08:48 UTC Re: Parallel Port to Power Supply Grounding Differential JanRwl@A... 2003-07-08 10:15:13 UTC Re: [CAD_CAM_EDM_DRO] Re: Parallel Port to Power Supply Grounding Differential Bill Kichman 2003-07-08 10:39:06 UTC Re: [CAD_CAM_EDM_DRO] Parallel Port to Power Supply Grounding Differential washcomp 2003-07-08 10:43:33 UTC Re: Parallel Port to Power Supply Grounding Differential Kim Lux 2003-07-08 11:12:47 UTC Gecko 320 heatsink requirements: needed ? Kim Lux 2003-07-08 11:29:18 UTC 5C collet closer drawbar threading problem Kim Lux 2003-07-08 11:48:44 UTC Re: [CAD_CAM_EDM_DRO] 5C collet closer drawbar threading problem Weyland 2003-07-08 13:55:57 UTC Re: [CAD_CAM_EDM_DRO] 5C collet closer drawbar threading problem doug98105 2003-07-08 14:20:51 UTC Re: 5C collet closer drawbar threading problem Kim Lux 2003-07-08 14:53:52 UTC Re: [CAD_CAM_EDM_DRO] Re: 5C collet closer drawbar threading problem Vince Negrete 2003-07-08 16:52:48 UTC Re: [CAD_CAM_EDM_DRO] Re: Parallel Port to Power Supply Grounding Differential Jon Elson 2003-07-08 21:48:03 UTC Re: [CAD_CAM_EDM_DRO] Gecko 320 heatsink requirements: needed ? Jon Elson 2003-07-08 21:53:56 UTC Re: [CAD_CAM_EDM_DRO] 5C collet closer drawbar threading problem Kim Lux 2003-07-08 22:59:09 UTC Re: [CAD_CAM_EDM_DRO] 5C collet closer drawbar threading problem