Parallel Port to Power Supply Grounding Differential

Posted by Bill Kichman
on 2003-07-07 18:58:24 UTC
Just wondering how other folks are ensuring they don't blow out their parallel ports via voltage differentials between the parallel port's #18-25 ground pins and the chassis ground at the power supply case? I am using Gecko 320's and a spare PC case housing a transformer fed linear 75V power supply (minus grounded to case) and (3) servo drives with rotary encoders. I measured the voltage differential between the power supply grounded case and the parallel port cable's grounds and measured about 3V. I guess I can manage to keep these grounds separate, since the Gecko uses opto-isolated interfaces, but should the (2) get inadvertently connected, I wouldn't want to "release the smoke genie". I read somewhere that somebody sells optoisolated breakout boards, but the (2) I could find in my search were not isolated. What are my options?
Thanks

R. William Kichman, P.E.
Kichman Engineering Associates
103 Old Furnace Road
Cornwall, PA 17016-0643
tel/fax 717/270-0714

[Non-text portions of this message have been removed]

Discussion Thread

Bill Kichman 2003-07-07 18:58:24 UTC Parallel Port to Power Supply Grounding Differential int3man 2003-07-07 21:48:51 UTC Re: Parallel Port to Power Supply Grounding Differential Jon Elson 2003-07-07 22:07:32 UTC Re: [CAD_CAM_EDM_DRO] Parallel Port to Power Supply Grounding Differential Tim Goldstein 2003-07-07 23:08:19 UTC RE: [CAD_CAM_EDM_DRO] Parallel Port to Power Supply Grounding Differential Bill Kichman 2003-07-08 05:47:27 UTC Re: [CAD_CAM_EDM_DRO] Parallel Port to Power Supply Grounding Differential turbulatordude 2003-07-08 07:16:07 UTC Re: Parallel Port to Power Supply Grounding Differential Jon Elson 2003-07-08 09:28:38 UTC Re: [CAD_CAM_EDM_DRO] Parallel Port to Power Supply Grounding Differential JanRwl@A... 2003-07-08 09:52:52 UTC Re: [CAD_CAM_EDM_DRO] Parallel Port to Power Supply Grounding Differential Rob WHITE 2003-07-08 09:59:44 UTC has anyone added a CNC system to this mill Don Rogers 2003-07-08 10:08:48 UTC Re: Parallel Port to Power Supply Grounding Differential JanRwl@A... 2003-07-08 10:15:13 UTC Re: [CAD_CAM_EDM_DRO] Re: Parallel Port to Power Supply Grounding Differential Bill Kichman 2003-07-08 10:39:06 UTC Re: [CAD_CAM_EDM_DRO] Parallel Port to Power Supply Grounding Differential washcomp 2003-07-08 10:43:33 UTC Re: Parallel Port to Power Supply Grounding Differential Kim Lux 2003-07-08 11:12:47 UTC Gecko 320 heatsink requirements: needed ? Kim Lux 2003-07-08 11:29:18 UTC 5C collet closer drawbar threading problem Kim Lux 2003-07-08 11:48:44 UTC Re: [CAD_CAM_EDM_DRO] 5C collet closer drawbar threading problem Weyland 2003-07-08 13:55:57 UTC Re: [CAD_CAM_EDM_DRO] 5C collet closer drawbar threading problem doug98105 2003-07-08 14:20:51 UTC Re: 5C collet closer drawbar threading problem Kim Lux 2003-07-08 14:53:52 UTC Re: [CAD_CAM_EDM_DRO] Re: 5C collet closer drawbar threading problem Vince Negrete 2003-07-08 16:52:48 UTC Re: [CAD_CAM_EDM_DRO] Re: Parallel Port to Power Supply Grounding Differential Jon Elson 2003-07-08 21:48:03 UTC Re: [CAD_CAM_EDM_DRO] Gecko 320 heatsink requirements: needed ? Jon Elson 2003-07-08 21:53:56 UTC Re: [CAD_CAM_EDM_DRO] 5C collet closer drawbar threading problem Kim Lux 2003-07-08 22:59:09 UTC Re: [CAD_CAM_EDM_DRO] 5C collet closer drawbar threading problem