Re: [CAD_CAM_EDM_DRO] Re: Question about AC power distribution in CNC controller box
Posted by
Alan Marconett KM6VV
on 2003-07-15 11:25:46 UTC
Hi G,
I can't quote from code, and your area might be different, but two line
cords (input modules) into the same box would not be wise, in my
opinion. Bolting grounded boxes together should not pose a problem, and
would actually be an elegant solution. The separate box may also keep
noise off the lines better!
HTH
Alan KM6VV
mrgamber wrote:
I can't quote from code, and your area might be different, but two line
cords (input modules) into the same box would not be wise, in my
opinion. Bolting grounded boxes together should not pose a problem, and
would actually be an elegant solution. The separate box may also keep
noise off the lines better!
HTH
Alan KM6VV
mrgamber wrote:
>
> Are you saying that code requires design to 220V?
>
> If I build the other box, is it an issue if the cases are bolted
> together?
>
> --- In CAD_CAM_EDM_DRO@yahoogroups.com, Alan Marconett KM6VV
> <KM6VV@a...> wrote:
> > Hi G,
> >
> > NOTE: (ASSUMES U.S. WIRING)
> >
> > I just did two switched outlets (Sherline spindle and AUX), and
> used the
> > same entry module. No problem there, single entry module.
> >
> > In your case, I'd be concerned with trying to parallel TWO entry
> > modules. The possibility exist that they could be plugged into
> > DIFFERENT halves of the split 220V (U.S. center grounded).
> Different
> > "circuits" in households (shops) can be on different "sides" of the
> A.C.
> > line. Best to get the rated entry module you require.
> > <SNIP>
> > HTH
> >
> > Alan KM6VV
Discussion Thread
mrgamber
2003-07-14 08:45:30 UTC
Question about AC power distribution in CNC controller box
Bernard R
2003-07-14 09:05:50 UTC
Re: Question about AC power distribution in CNC controller box
mrgamber
2003-07-14 09:14:46 UTC
Re: Question about AC power distribution in CNC controller box
eferg2001
2003-07-14 09:26:28 UTC
Re: Question about AC power distribution in CNC controller box
Alan Marconett KM6VV
2003-07-14 17:13:02 UTC
Re: [CAD_CAM_EDM_DRO] Question about AC power distribution in CNC controller box
mrgamber
2003-07-15 07:29:19 UTC
Re: Question about AC power distribution in CNC controller box
Alan Marconett KM6VV
2003-07-15 11:25:46 UTC
Re: [CAD_CAM_EDM_DRO] Re: Question about AC power distribution in CNC controller box
mrgamber
2003-07-15 16:00:25 UTC
Re: Question about AC power distribution in CNC controller box
Alan Marconett KM6VV
2003-07-15 19:33:12 UTC
Re: [CAD_CAM_EDM_DRO] Re: Question about AC power distribution in CNC controller box