There's no place like home Re: G code
Posted by
ballendo
on 2004-02-02 07:27:50 UTC
Doug,
Again I agree with Fred. (I added the "zero in G53" to my post so
that any confusion would have a "home"<G>)
FWIW, I've always thought of HOME as the machine zero reference; and
the "reference" point as some point that I've set with offsets...
Using this understanding:
Home never changes. The reference point can, and does...
(Which makes it the opposite of what your machine calls things)
But I've never heard part zero referred to as home...
Ballendo
P.S. What control(s) are you using? Are they older controls?
Again I agree with Fred. (I added the "zero in G53" to my post so
that any confusion would have a "home"<G>)
FWIW, I've always thought of HOME as the machine zero reference; and
the "reference" point as some point that I've set with offsets...
Using this understanding:
Home never changes. The reference point can, and does...
(Which makes it the opposite of what your machine calls things)
But I've never heard part zero referred to as home...
Ballendo
P.S. What control(s) are you using? Are they older controls?
>In CCED, "doug98105" <DougR@a...> wrote:with G27, G28, and G29, each with it's own capability.
>>CCED, "ballendo" <ballendo@y...> wrote:
> > > In CCED, "Fred Smith" <imserv@v...> wrote:
> > > Most controls do have a command for homing. On Fanuc it is
> > Hello,is
> > Fred is right. Just want to add a bit about those "capabilities":
> >
> > Of the three he mentions, only the G27 is really a "home-ING"
> > command. Because it is the one that RESETS the machine position
> > according to the switches.
> >
> > The G28 is a RETURN to the home POSITION. (without checking the
> > switches. But on many controls there will be "home" indicator
> lights
> > which may or may not signify having reached the actual--according
> to
> > the switches--home point. In other words, they may light up
> whenever
> > the axis readouts are at zero in G53--the machine coord system.)
> >
> > And G29 is a return FROM the home position. (again without
> > any "check" of the position.)
> >
> > Both G28 and G29 usually allow an intermediate point to be
> > included "on-the-way" to the home position. This is used to stay
> > clear of the work or work-holding devices.
> >
> > There are a few controls which use an M code for homing, and it
> > often a high number like M101.
> >
> > And on some controls, you could set up a homing routine using the
> > macro language, and then alias it to a given G code...
> >
> > Hope this helps,
> >
> > Ballendo
>
> I get the feeling that everyone who is participating in this thread
> is not talking about the same thing when they mention HOME.
>
> One of my machines has HOME, REFERENCE, and may have a part ZERO
> position. The HOME and part ZERO are user specified. REFERENCE
> position is determined by hardware. At various times I've seen all
> of these called HOME. So which are you guys talking about?
>
> Doug
Discussion Thread
Gene
2002-05-21 16:25:24 UTC
G code
Jon Elson
2002-05-21 21:46:57 UTC
Re: [CAD_CAM_EDM_DRO] G code
Gene
2002-05-21 22:16:29 UTC
Re: [CAD_CAM_EDM_DRO] G code
Tim Goldstein
2002-05-21 22:25:57 UTC
RE: [CAD_CAM_EDM_DRO] G code
Gene
2002-05-21 22:30:20 UTC
Re: [CAD_CAM_EDM_DRO] G code
Tim Goldstein
2002-05-21 22:38:56 UTC
RE: [CAD_CAM_EDM_DRO] G code
bjammin@i...
2002-05-22 03:04:37 UTC
Re: [CAD_CAM_EDM_DRO] G code
turbulatordude
2002-05-22 06:10:26 UTC
Re: G code
Carol & Jerry Jankura
2002-05-22 16:58:01 UTC
RE: [CAD_CAM_EDM_DRO] Re: G code
turbulatordude
2002-05-22 19:12:51 UTC
Re: G code
Jon Elson
2002-05-22 22:07:25 UTC
Re: [CAD_CAM_EDM_DRO] G code
Jon Elson
2002-05-22 22:16:23 UTC
Re: [CAD_CAM_EDM_DRO] Re: G code
Ray Henry
2002-05-23 06:04:00 UTC
Re: Re: Re: G code
shelbyshepherd2002
2003-12-14 01:35:43 UTC
G code
Nigel Christianson
2003-12-14 06:25:05 UTC
Re: G code
cnc002@a...
2003-12-14 09:11:08 UTC
Re: [CAD_CAM_EDM_DRO] Re: G code
shelbyshepherd2002
2003-12-14 10:35:38 UTC
Re: G code
shelbyshepherd2002
2004-01-31 03:25:27 UTC
G code
Jon Elson
2004-01-31 11:08:51 UTC
Re: [CAD_CAM_EDM_DRO] G code
Fred Smith
2004-01-31 19:30:39 UTC
Re: G code
cnc002@a...
2004-01-31 19:34:59 UTC
Re: [CAD_CAM_EDM_DRO] Re: G code
piggy
2004-01-31 20:05:20 UTC
Re: [CAD_CAM_EDM_DRO] Re: G code
ballendo
2004-02-01 07:30:31 UTC
There's no place like home Re: G code
doug98105
2004-02-01 09:48:43 UTC
There's no place like home Re: G code
Fred Smith
2004-02-01 16:09:52 UTC
There's no place like home Re: G code
ballendo
2004-02-02 07:27:50 UTC
There's no place like home Re: G code
wanliker@a...
2006-03-13 11:46:05 UTC
G code