Re: Why is the push to such high step rates (Grex and Arc100)?
Posted by
lcdpublishing
on 2006-12-18 13:08:38 UTC
That's cool, I can understand and appreciate that. I also understand
that the cost difference isn't there (between 1 and 20 Mhz) and that
has not been my concern. I was just trying to find out if there is
any practicality to have a pulse stream running at 4 Mhz within motion
control. If there is, it must be some VERY interesting technology,
extremly fast and accurate!
Thanks for clearing that up.
Chris
that the cost difference isn't there (between 1 and 20 Mhz) and that
has not been my concern. I was just trying to find out if there is
any practicality to have a pulse stream running at 4 Mhz within motion
control. If there is, it must be some VERY interesting technology,
extremly fast and accurate!
Thanks for clearing that up.
Chris
> I don't know of anything above 1MHZ but since designing/testing these
> boards has been a 2 man-year project I am not about to play that
> close. I prefer multiplying everything by 4 and not have to redo the
> board when some new application comes along. The cost is absolutely
> the same in terms of hardware for 1MHZ vs 4 MHZ and even higher.
>
> Patrick Robin
>
Discussion Thread
lcdpublishing
2006-12-18 07:09:10 UTC
Why is the push to such high step rates (Grex and Arc100)?
Mariss Freimanis
2006-12-18 08:30:26 UTC
Re: Why is the push to such high step rates (Grex and Arc100)?
turbulatordude
2006-12-18 09:00:14 UTC
Re: Why is the push to such high step rates (Grex and Arc100)?
lcdpublishing
2006-12-18 09:13:32 UTC
Re: Why is the push to such high step rates (Grex and Arc100)?
turbulatordude
2006-12-18 10:14:19 UTC
Re: Why is the push to such high step rates (Grex and Arc100)?
caudlet
2006-12-18 10:31:11 UTC
Re: Why is the push to such high step rates (Grex and Arc100)?
lcdpublishing
2006-12-18 11:06:01 UTC
Re: Why is the push to such high step rates (Grex and Arc100)?
Mariss Freimanis
2006-12-18 11:20:22 UTC
Re: Why is the push to such high step rates (Grex and Arc100)?
lcdpublishing
2006-12-18 11:45:42 UTC
Re: Why is the push to such high step rates (Grex and Arc100)?
Fred Smith
2006-12-18 11:45:55 UTC
Re: Why is the push to such high step rates (Grex and Arc100)?
C.S. Mo
2006-12-18 12:14:34 UTC
Re: [CAD_CAM_EDM_DRO] Re: Why is the push to such high step rates (Grex and Arc100)?
atelierrobin
2006-12-18 12:22:02 UTC
Re: Why is the push to such high step rates (Grex and Arc100)?
lcdpublishing
2006-12-18 12:32:27 UTC
Re: Why is the push to such high step rates (Grex and Arc100)?
Leslie Newell
2006-12-18 12:39:43 UTC
Re: [CAD_CAM_EDM_DRO] Re: Why is the push to such high step rates (Grex and Arc100)?
lcdpublishing
2006-12-18 12:41:58 UTC
Re: Why is the push to such high step rates (Grex and Arc100)?
lcdpublishing
2006-12-18 12:53:38 UTC
Re: Why is the push to such high step rates (Grex and Arc100)?
atelierrobin
2006-12-18 12:58:12 UTC
Re: Why is the push to such high step rates (Grex and Arc100)?
Mark Vaughan
2006-12-18 13:05:57 UTC
RE: [CAD_CAM_EDM_DRO] Re: Why is the push to such high step rates (Grex and Arc100)?
lcdpublishing
2006-12-18 13:08:38 UTC
Re: Why is the push to such high step rates (Grex and Arc100)?
John Dammeyer
2006-12-18 14:20:46 UTC
RE: [CAD_CAM_EDM_DRO] Re: Why is the push to such high step rates (Grex and Arc100)?
Tony Smith
2006-12-18 14:25:18 UTC
RE: [CAD_CAM_EDM_DRO] Re: Why is the push to such high step rates (Grex and Arc100)?
lcdpublishing
2006-12-18 14:33:30 UTC
Re: Why is the push to such high step rates (Grex and Arc100)?
Leslie Newell
2006-12-18 14:46:59 UTC
Re: [CAD_CAM_EDM_DRO] Re: Why is the push to such high step rates (Grex and Arc100)?
Leslie Newell
2006-12-18 14:48:02 UTC
Re: [CAD_CAM_EDM_DRO] Re: Why is the push to such high step rates (Grex and Arc100)?
Fred Smith
2006-12-18 15:01:55 UTC
Re: Why is the push to such high step rates (Grex and Arc100)?
John Dammeyer
2006-12-18 15:16:54 UTC
RE: [CAD_CAM_EDM_DRO] Re: Why is the push to such high step rates (Grex and Arc100)?
Jon Elson
2006-12-18 20:47:23 UTC
Re: [CAD_CAM_EDM_DRO] Re: Why is the push to such high step rates (Grex and Arc100)?
Jon Elson
2006-12-18 20:47:37 UTC
Re: [CAD_CAM_EDM_DRO] Re: Why is the push to such high step rates (Grex and Arc100)?
turbulatordude
2006-12-19 04:58:10 UTC
Re: Why is the push to such high step rates (Grex and Arc100)?
lcdpublishing
2006-12-19 05:15:37 UTC
Re: Why is the push to such high step rates (Grex and Arc100)?
lcdpublishing
2006-12-19 05:29:33 UTC
Re: Why is the push to such high step rates (Grex and Arc100)?
Jon Elson
2006-12-19 07:59:03 UTC
Re: [CAD_CAM_EDM_DRO] Re: Why is the push to such high step rates (Grex and Arc100)?
Graham Stabler
2006-12-19 08:38:12 UTC
Re: Why is the push to such high step rates (Grex and Arc100)?
lcdpublishing
2006-12-19 08:56:42 UTC
Re: Why is the push to such high step rates (Grex and Arc100)?
Graham Stabler
2006-12-19 09:46:05 UTC
Re: Why is the push to such high step rates (Grex and Arc100)?
optics22000
2006-12-19 10:27:16 UTC
Re: Why is the push to such high step rates (Grex and Arc100)?
John Dammeyer
2006-12-19 11:04:49 UTC
CNCing a 7x12 minilathe
Graham Stabler
2006-12-19 12:06:19 UTC
Re: Why is the push to such high step rates (Grex and Arc100)?
Peter Homann
2006-12-19 12:12:22 UTC
Re: [CAD_CAM_EDM_DRO] CNCing a 7x12 minilathe
John Dammeyer
2006-12-19 12:47:34 UTC
RE: [CAD_CAM_EDM_DRO] CNCing a 7x12 minilathe
David Bloomfield
2006-12-20 04:09:10 UTC
Re: Why is the push to such high step rates (Grex and Arc100)?