Re: [CAD_CAM_EDM_DRO] Hurco KM-3 retrofit
Posted by
Jon Elson
on 2012-05-19 11:43:46 UTC
Ron Thompson wrote:
some of
the limit switch connections. I don't know if it has the enable and
fault signals on
that doc. That should be all you need.
Jon
>>It definitely shows how to connect the command input and tach, and shows
> Thanks again, Jon.
> I had found this, but not much else. The PDF seems to be the correct
> info for the drives. I'll know more on the next visit.
>
>
some of
the limit switch connections. I don't know if it has the enable and
fault signals on
that doc. That should be all you need.
Jon
Discussion Thread
Ron Thompson
2012-05-18 14:57:57 UTC
Hurco KM-3 retrofit
David G. LeVine
2012-05-18 18:21:30 UTC
Re: [CAD_CAM_EDM_DRO] Hurco KM-3 retrofit
Jon Elson
2012-05-18 18:21:57 UTC
Re: [CAD_CAM_EDM_DRO] Hurco KM-3 retrofit
Ron Thompson
2012-05-18 18:41:13 UTC
Re: [CAD_CAM_EDM_DRO] Hurco KM-3 retrofit
Ron Thompson
2012-05-18 18:44:07 UTC
Re: [CAD_CAM_EDM_DRO] Hurco KM-3 retrofit
Jon Elson
2012-05-18 20:52:30 UTC
Re: [CAD_CAM_EDM_DRO] Hurco KM-3 retrofit
Ron Thompson
2012-05-19 05:30:18 UTC
Re: [CAD_CAM_EDM_DRO] Hurco KM-3 retrofit
David G. LeVine
2012-05-19 09:42:29 UTC
Re: [CAD_CAM_EDM_DRO] Hurco KM-3 retrofit
Jon Elson
2012-05-19 11:43:46 UTC
Re: [CAD_CAM_EDM_DRO] Hurco KM-3 retrofit
Ron Thompson
2012-05-19 12:24:56 UTC
Re: [CAD_CAM_EDM_DRO] Hurco KM-3 retrofit
Jon Elson
2012-05-19 17:46:03 UTC
Re: [CAD_CAM_EDM_DRO] Hurco KM-3 retrofit