Re: [CAD_CAM_EDM_DRO] 67 Amp 5 Volt Regulated Supply
Posted by
Jon Elson
on 2001-07-14 15:54:39 UTC
jeffrosselthecat@... wrote:
internal 5 V power by regulating down the raw DC input, so it may
not work at all due to voltage drop in the regulator. If it does
work, the power output from the steppers would be incredibly
low.
Unless this thing weighs at least 75 Lbs, you won't be able to use
the transformers, as this is likely a switching power supply, and
those transformers are designed for 25 KHz input, not 60 Hz.
There probably aren't 2 transformers, only one, and a filter
inductor. If this is an LHS-5 or LYS-5 model, those are, indeed,
switching supplies.
Jon
> I cam across a 67 Amp 5 Volt Regulated SupplyI really don't think this will work. I think that driver derives its
> from LAMDA(?) research and would like to use it with Dan's 5 Amp
> stepper driver. Can his boards accept a 5 volt input? If I have to
> I'll pick the thing over for the (2) transformers inside (use one &
> sell the other).
internal 5 V power by regulating down the raw DC input, so it may
not work at all due to voltage drop in the regulator. If it does
work, the power output from the steppers would be incredibly
low.
Unless this thing weighs at least 75 Lbs, you won't be able to use
the transformers, as this is likely a switching power supply, and
those transformers are designed for 25 KHz input, not 60 Hz.
There probably aren't 2 transformers, only one, and a filter
inductor. If this is an LHS-5 or LYS-5 model, those are, indeed,
switching supplies.
Jon
Discussion Thread
jeffrosselthecat@y...
2001-07-14 07:43:02 UTC
67 Amp 5 Volt Regulated Supply
Alan Marconett KM6VV
2001-07-14 12:28:14 UTC
Re: [CAD_CAM_EDM_DRO] 67 Amp 5 Volt Regulated Supply
Jon Elson
2001-07-14 15:54:39 UTC
Re: [CAD_CAM_EDM_DRO] 67 Amp 5 Volt Regulated Supply
jeffrosselthecat@y...
2001-07-15 08:06:49 UTC
Re: 67 Amp 5 Volt Regulated Supply
Larry Edington
2001-07-15 17:51:44 UTC
Re: [CAD_CAM_EDM_DRO] 67 Amp 5 Volt Regulated Supply
Alan Marconett KM6VV
2001-07-16 11:35:40 UTC
Re: [CAD_CAM_EDM_DRO] 67 Amp 5 Volt Regulated Supply
Jon Elson
2001-07-16 22:44:07 UTC
Re: [CAD_CAM_EDM_DRO] 67 Amp 5 Volt Regulated Supply
Alan Marconett KM6VV
2001-07-17 12:51:14 UTC
Re: [CAD_CAM_EDM_DRO] 67 Amp 5 Volt Regulated Supply
ballendo@y...
2001-07-17 21:47:44 UTC
Re: 67 Amp 5 Volt Regulated Supply
ballendo@y...
2001-07-17 21:56:07 UTC
Re: 67 Amp 5 Volt Regulated Supply
Jon Elson
2001-07-17 23:12:29 UTC
Re: [CAD_CAM_EDM_DRO] Re: 67 Amp 5 Volt Regulated Supply
ballendo@y...
2001-07-18 11:44:36 UTC
Re: 67 Amp 5 Volt Regulated Supply
Jon Elson
2001-08-01 20:10:26 UTC
Re: [CAD_CAM_EDM_DRO] 67 Amp 5 Volt Regulated Supply
Alan Marconett KM6VV
2001-08-01 22:46:54 UTC
Re: [CAD_CAM_EDM_DRO] 67 Amp 5 Volt Regulated Supply