CAD CAM EDM DRO - Yahoo Group Archive

Re: [CAD_CAM_EDM_DRO] 8 wire steppers, parallel. series or single winding?

Posted by Jon Elson
on 2002-04-12 22:43:38 UTC
"j.guenther" wrote:

> Jon,
>
> The machine is a Sherline 5400, 20TPI lead screws direct drive. The current
> reliable top speed is 13.4 IPM. The motors are 80oz/in Pacific Scientific
> motors, rated at .52 amps and IIRC 5.47 volts per phase.

I should also mention that that combination, .5A at 5.5 V is a bad combination,
low current and lots of winding inductance really limits the top speed of
the motors. 1.8 V at 1.5 A would be a better motor combination, for
example (more current, lower voltage).

Jon

Discussion Thread

John Guenther 2002-04-12 05:27:30 UTC 8 wire steppers, parallel. series or single winding? Bob Campbell 2002-04-12 07:19:00 UTC RE: [CAD_CAM_EDM_DRO] 8 wire steppers, parallel. series or single winding? j.guenther 2002-04-12 08:00:53 UTC RE: [CAD_CAM_EDM_DRO] 8 wire steppers, parallel. series or single winding? studleylee 2002-04-12 09:24:18 UTC Re: 8 wire steppers, parallel. series or single winding? stephen_stallings 2002-04-12 10:33:02 UTC Re: 8 wire steppers, parallel. series or single winding? Jon Elson 2002-04-12 11:03:00 UTC Re: [CAD_CAM_EDM_DRO] 8 wire steppers, parallel. series or single winding? j.guenther 2002-04-12 11:24:46 UTC RE: [CAD_CAM_EDM_DRO] 8 wire steppers, parallel. series or single winding? Tim Goldstein 2002-04-12 12:12:42 UTC Re: [CAD_CAM_EDM_DRO] 8 wire steppers, parallel. series or single winding? mariss92705 2002-04-12 14:06:46 UTC Re: 8 wire steppers, parallel. series or single winding? JanRwl@A... 2002-04-12 21:41:57 UTC Re: [CAD_CAM_EDM_DRO] 8 wire steppers, parallel. series or single winding? Jon Elson 2002-04-12 22:39:50 UTC Re: [CAD_CAM_EDM_DRO] 8 wire steppers, parallel. series or single winding? Jon Elson 2002-04-12 22:43:38 UTC Re: [CAD_CAM_EDM_DRO] 8 wire steppers, parallel. series or single winding? Carol & Jerry Jankura 2002-04-13 05:57:22 UTC RE: [CAD_CAM_EDM_DRO] 8 wire steppers, parallel. series or single winding?