Transfering to a Dyna Myte through the RS232 using Cimco Edit
Posted by
andersmalpass
on 2003-04-01 16:12:14 UTC
I can't get this to work; I must be doing something wrong. I have a
computer with only Cismo edit on it with a small program that I have
made from mastercam and posted it with the correct post on to cimco
edit. I have configured the DNS settings in Cimco edit so I can use
the DNS transfer program in there:
Baud rate 2400
Stop bits 1
Data bits 8
Has anyone done this before on a Dyna Myte 2800 or 2400 (They have
the same control) I would like to write programs in a cam software
package, post them and than transfer them across the RS232 into the
machine? I think that I have everything configured correctly but it's
still not working. I have the cable configuration correct or so I
think, I got the original configuration from Dyna, I have tested for
signal and it's definitely sending signal to the machine but the
machine controller is not responding.
Any ideas?
I don't know much about these Dyna Myte mills however, any help would
be much appreciated.
What are my options here, I know that there is a AHHA retrofit, but I
would prefer to solve this without having to purchase the retrofit
because it works in dos and I would like to keep running windows xp.
Are there any other retrofits out there for my machine?
Thanks for the help, it's much appreciated.
computer with only Cismo edit on it with a small program that I have
made from mastercam and posted it with the correct post on to cimco
edit. I have configured the DNS settings in Cimco edit so I can use
the DNS transfer program in there:
Baud rate 2400
Stop bits 1
Data bits 8
Has anyone done this before on a Dyna Myte 2800 or 2400 (They have
the same control) I would like to write programs in a cam software
package, post them and than transfer them across the RS232 into the
machine? I think that I have everything configured correctly but it's
still not working. I have the cable configuration correct or so I
think, I got the original configuration from Dyna, I have tested for
signal and it's definitely sending signal to the machine but the
machine controller is not responding.
Any ideas?
I don't know much about these Dyna Myte mills however, any help would
be much appreciated.
What are my options here, I know that there is a AHHA retrofit, but I
would prefer to solve this without having to purchase the retrofit
because it works in dos and I would like to keep running windows xp.
Are there any other retrofits out there for my machine?
Thanks for the help, it's much appreciated.
Discussion Thread
andersmalpass
2003-04-01 16:12:14 UTC
Transfering to a Dyna Myte through the RS232 using Cimco Edit
caudlet
2003-04-01 16:55:53 UTC
Re: Transfering to a Dyna Myte through the RS232 using Cimco Edit
caudlet
2003-04-01 17:12:13 UTC
Re: Transfering to a Dyna Myte (more answer...)
James Wilsom
2003-04-01 18:32:07 UTC
Re: [CAD_CAM_EDM_DRO] Re: Transfering to a Dyna Myte (more answer...)
a M
2003-04-02 22:04:59 UTC
Re: [CAD_CAM_EDM_DRO] Re: Transfering to a Dyna Myte (more answer...)
James Wilsom
2003-04-03 07:35:58 UTC
Re: [CAD_CAM_EDM_DRO] Re: Transfering to a Dyna Myte (more answer...)
Chris Brick
2003-04-03 08:08:44 UTC
Re: [CAD_CAM_EDM_DRO] Re: Transfering to a Dyna Myte (more answer...)
James Wilsom
2003-04-03 15:51:29 UTC
Re: [CAD_CAM_EDM_DRO] Re: Transfering to a Dyna Myte (more answer...)