Re: [CAD_CAM_EDM_DRO] GE 1050CM control
Posted by
Jon Elson
on 2002-07-04 22:30:41 UTC
Harlan Gustafson wrote:
ISA slots are getting pretty rare in PC's now. My parallel port motion control
board set will also work, and there's nothing needed inside the computer.
input to it.
boxes that can convert resolver signals to quadrature, but they may be
expensive.
Jon
> Jon:If they are +/- 10 V signals, then the Servo-to-Go should work. Of course,
> Is "Servo-to-Go" the way to go for interface cards? Will those cards drive
> my Gettys N360 drives.
ISA slots are getting pretty rare in PC's now. My parallel port motion control
board set will also work, and there's nothing needed inside the computer.
> I think they are 30-40 amp drives.The current output of the servo amp has no connection to the velocity command
input to it.
> Should I convertThe Servo-to-Go and my cards need quadrature signals. There are converter
> from resolvers to encoders or is that not necessary?
boxes that can convert resolver signals to quadrature, but they may be
expensive.
Jon
Discussion Thread
accellodyne
2002-06-06 23:02:48 UTC
GE 1050CM control
Ray Henry
2002-06-07 05:25:52 UTC
Re: GE 1050CM control
Harlan Gustafson
2002-06-07 08:38:06 UTC
Re: [CAD_CAM_EDM_DRO] Re: GE 1050CM control
Michael Milligan
2002-06-07 11:34:59 UTC
RE: [CAD_CAM_EDM_DRO] Re: GE 1050CM control
Jon Elson
2002-06-07 12:08:13 UTC
Re: [CAD_CAM_EDM_DRO] GE 1050CM control
Ray Henry
2002-06-07 13:01:09 UTC
Re: Re: Re: GE 1050CM control
Harlan Gustafson
2002-06-08 13:26:42 UTC
Re: [CAD_CAM_EDM_DRO] GE 1050CM control
Harlan Gustafson
2002-06-08 13:46:47 UTC
Re: [CAD_CAM_EDM_DRO] Re: Re: Re: GE 1050CM control
Harlan Gustafson
2002-06-08 13:53:45 UTC
Re: [CAD_CAM_EDM_DRO] Re: GE 1050CM control
Jon Elson
2002-06-08 15:39:25 UTC
Re: [CAD_CAM_EDM_DRO] GE 1050CM control
Jon Elson
2002-06-08 15:52:56 UTC
Re: [CAD_CAM_EDM_DRO] Re: Re: Re: GE 1050CM control
Jon Elson
2002-06-08 16:01:38 UTC
Re: [CAD_CAM_EDM_DRO] Re: GE 1050CM control
Ray Henry
2002-06-09 07:45:05 UTC
Re: Re: Re: Re: Re: GE 1050CM control
Harlan Gustafson
2002-06-26 11:14:02 UTC
Re: [CAD_CAM_EDM_DRO] GE 1050CM control
Jon Elson
2002-06-26 19:14:33 UTC
Re: [CAD_CAM_EDM_DRO] GE 1050CM control
Harlan Gustafson
2002-07-02 16:13:58 UTC
Re: [CAD_CAM_EDM_DRO] GE 1050CM control
Doug Harrison
2002-07-02 20:39:03 UTC
Re: [CAD_CAM_EDM_DRO] GE 1050CM control
Jon Elson
2002-07-02 21:12:22 UTC
Re: [CAD_CAM_EDM_DRO] GE 1050CM control
Joll503@A...
2002-07-02 22:38:50 UTC
Re: [CAD_CAM_EDM_DRO] GE 1050CM control
William Scalione
2002-07-02 22:46:17 UTC
Re: [CAD_CAM_EDM_DRO] GE 1050CM control
rainnea
2002-07-03 01:23:58 UTC
Re: GE 1050CM control
Harlan Gustafson
2002-07-03 05:54:30 UTC
Re: [CAD_CAM_EDM_DRO] Re: GE 1050CM control
rainnea
2002-07-03 06:06:02 UTC
Re: GE 1050CM control
Harlan Gustafson
2002-07-03 07:28:38 UTC
Re: [CAD_CAM_EDM_DRO] GE 1050CM control
Harlan Gustafson
2002-07-03 11:45:51 UTC
Re: [CAD_CAM_EDM_DRO] GE 1050CM control
Bill Vance
2002-07-03 12:20:52 UTC
Re: [CAD_CAM_EDM_DRO] GE 1050CM control
Ray Henry
2002-07-03 18:19:11 UTC
Re: Re: GE 1050CM control
Jon Elson
2002-07-03 22:55:17 UTC
Re: [CAD_CAM_EDM_DRO] GE 1050CM control
Harlan Gustafson
2002-07-04 10:21:37 UTC
Re: [CAD_CAM_EDM_DRO] GE 1050CM control
Jon Elson
2002-07-04 11:00:31 UTC
Re: [CAD_CAM_EDM_DRO] GE 1050CM control
Harlan Gustafson
2002-07-04 11:29:50 UTC
Re: [CAD_CAM_EDM_DRO] GE 1050CM control
Jon Elson
2002-07-04 22:30:41 UTC
Re: [CAD_CAM_EDM_DRO] GE 1050CM control
Ray Henry
2002-07-05 08:05:38 UTC
Re: Re: GE 1050CM control
Ray Henry
2002-07-05 08:07:47 UTC
Re: Re: GE 1050CM control