R Rogers wrote:

>Sorry, I misread the ad pertaining to the continuous amperage rating. However no Amperage limit is stated as well as stall torque. My motors are rated at 40 lb/in or in/lb with a 5/8" shaft these are more powerful with a 3/8" shaft?
>
>
Quoting from the ad :

Torque Constant, kt = 5.5 lb-In/Amp WOW!

_That's PER Amp of motor current._

At just 10 amps, that's 55 Lb-In = 880 Oz-In.

So, the question is what the peak current limit is, 10A or 20!

Jon

Discussion Thread

feck123 2004-09-23 22:22:39 UTC nema 34 motors on BP series 1 conversion Stephen Wille Padnos 2004-09-23 23:33:50 UTC Re: [CAD_CAM_EDM_DRO] nema 34 motors on BP series 1 conversion R Rogers 2004-09-24 07:03:52 UTC Re: [CAD_CAM_EDM_DRO] nema 34 motors on BP series 1 conversion vavaroutsos 2004-09-24 08:58:05 UTC Re: nema 34 motors on BP series 1 conversion jlsmith269 2004-09-24 09:03:13 UTC Re: nema 34 motors on BP series 1 conversion Jon Elson 2004-09-24 09:22:04 UTC Re: [CAD_CAM_EDM_DRO] nema 34 motors on BP series 1 conversion Jon Elson 2004-09-24 09:29:02 UTC Re: [CAD_CAM_EDM_DRO] nema 34 motors on BP series 1 conversion R Rogers 2004-09-24 09:34:53 UTC Re: [CAD_CAM_EDM_DRO] Re: nema 34 motors on BP series 1 conversion R Rogers 2004-09-24 10:48:44 UTC Re: [CAD_CAM_EDM_DRO] nema 34 motors on BP series 1 conversion Stephen Wille Padnos 2004-09-24 11:01:55 UTC Re: [CAD_CAM_EDM_DRO] nema 34 motors on BP series 1 conversion R Rogers 2004-09-24 11:33:37 UTC Re: [CAD_CAM_EDM_DRO] nema 34 motors on BP series 1 conversion R Rogers 2004-09-24 11:35:42 UTC Re: [CAD_CAM_EDM_DRO] nema 34 motors on BP series 1 conversion Andy Wander 2004-09-24 11:39:23 UTC RE: [CAD_CAM_EDM_DRO] nema 34 motors on BP series 1 conversion Stephen Wille Padnos 2004-09-24 11:47:48 UTC Re: [CAD_CAM_EDM_DRO] nema 34 motors on BP series 1 conversion R Rogers 2004-09-24 11:52:25 UTC RE: [CAD_CAM_EDM_DRO] nema 34 motors on BP series 1 conversion R Rogers 2004-09-24 12:05:56 UTC Re: [CAD_CAM_EDM_DRO] nema 34 motors on BP series 1 conversion Andy Wander 2004-09-24 12:07:46 UTC RE: [CAD_CAM_EDM_DRO] nema 34 motors on BP series 1 conversion R Rogers 2004-09-24 12:42:06 UTC RE: [CAD_CAM_EDM_DRO] nema 34 motors on BP series 1 conversion Andy Wander 2004-09-24 12:54:04 UTC RE: [CAD_CAM_EDM_DRO] nema 34 motors on BP series 1 conversion Andy Wander 2004-09-24 12:57:29 UTC RE: [CAD_CAM_EDM_DRO] nema 34 motors on BP series 1 conversion R Rogers 2004-09-24 13:16:28 UTC RE: [CAD_CAM_EDM_DRO] nema 34 motors on BP series 1 conversion R Rogers 2004-09-24 13:28:26 UTC RE: [CAD_CAM_EDM_DRO] nema 34 motors on BP series 1 conversion Andy Wander 2004-09-24 13:30:23 UTC RE: [CAD_CAM_EDM_DRO] nema 34 motors on BP series 1 conversion Andy Wander 2004-09-24 13:31:25 UTC RE: [CAD_CAM_EDM_DRO] nema 34 motors on BP series 1 conversion Jon Elson 2004-09-24 20:31:28 UTC Re: [CAD_CAM_EDM_DRO] nema 34 motors on BP series 1 conversion Jon Elson 2004-09-24 20:35:17 UTC Re: [CAD_CAM_EDM_DRO] nema 34 motors on BP series 1 conversion Boss 2004-09-24 20:39:29 UTC Re: [CAD_CAM_EDM_DRO] nema 34 motors on BP series 1 conversion R Rogers 2004-09-25 07:32:14 UTC Re: [CAD_CAM_EDM_DRO] nema 34 motors on BP series 1 conversion Bill Vance 2005-01-24 15:58:01 UTC Re: [CAD_CAM_EDM_DRO] nema 34 motors on BP series 1 conversionnccq