Re: [CAD_CAM_EDM_DRO] nema 34 motors on BP series 1 conversion
Posted by
R Rogers
on 2004-09-25 07:32:14 UTC
Jon,
Someone said they are rated @ 2 amps continuous making them like 176 oz-in. The 10 amps is stall. But they can't be expected to perform at stall torque. Not for very long anyway.
Ron
Jon Elson <elson@...> wrote:
R Rogers wrote:
Torque Constant, kt = 5.5 lb-In/Amp WOW!
_That's PER Amp of motor current._
At just 10 amps, that's 55 Lb-In = 880 Oz-In.
So, the question is what the peak current limit is, 10A or 20!
Jon
Addresses:
FAQ: http://www.ktmarketing.com/faq.html
FILES: http://groups.yahoo.com/group/CAD_CAM_EDM_DRO/files/
Post Messages: CAD_CAM_EDM_DRO@yahoogroups.com
Subscribe: CAD_CAM_EDM_DRO-subscribe@yahoogroups.com
Unsubscribe: CAD_CAM_EDM_DRO-unsubscribe@yahoogroups.com
List owner: CAD_CAM_EDM_DRO-owner@yahoogroups.com, wanliker@..., timg@...
Moderator: pentam@... indigo_red@... davemucha@... [Moderators]
URL to this group: http://groups.yahoo.com/group/CAD_CAM_EDM_DRO
OFF Topic POSTS: General Machining
If you wish to post on unlimited OT subjects goto: aol://5863:126/rec.crafts.metalworking or go thru Google.com to reach it if you have trouble.
http://www.metalworking.com/news_servers.html
http://groups.yahoo.com/group/jobshophomeshop I consider this to be a sister site to the CCED group, as many of the same members are there, for OT subjects, that are not allowed on the CCED list.
NOTICE: ALL POSTINGS TO THIS GROUP BECOME PUBLIC DOMAIN BY POSTING THEM. DON'T POST IF YOU CAN NOT ACCEPT THIS.....NO EXCEPTIONS........
bill
List Mom
List Owner
Yahoo! Groups Links
---------------------------------
Do you Yahoo!?
Y! Messenger - Communicate in real time. Download now.
[Non-text portions of this message have been removed]
Someone said they are rated @ 2 amps continuous making them like 176 oz-in. The 10 amps is stall. But they can't be expected to perform at stall torque. Not for very long anyway.
Ron
Jon Elson <elson@...> wrote:
R Rogers wrote:
>Sorry, I misread the ad pertaining to the continuous amperage rating. However no Amperage limit is stated as well as stall torque. My motors are rated at 40 lb/in or in/lb with a 5/8" shaft these are more powerful with a 3/8" shaft?Quoting from the ad :
>
>
Torque Constant, kt = 5.5 lb-In/Amp WOW!
_That's PER Amp of motor current._
At just 10 amps, that's 55 Lb-In = 880 Oz-In.
So, the question is what the peak current limit is, 10A or 20!
Jon
Addresses:
FAQ: http://www.ktmarketing.com/faq.html
FILES: http://groups.yahoo.com/group/CAD_CAM_EDM_DRO/files/
Post Messages: CAD_CAM_EDM_DRO@yahoogroups.com
Subscribe: CAD_CAM_EDM_DRO-subscribe@yahoogroups.com
Unsubscribe: CAD_CAM_EDM_DRO-unsubscribe@yahoogroups.com
List owner: CAD_CAM_EDM_DRO-owner@yahoogroups.com, wanliker@..., timg@...
Moderator: pentam@... indigo_red@... davemucha@... [Moderators]
URL to this group: http://groups.yahoo.com/group/CAD_CAM_EDM_DRO
OFF Topic POSTS: General Machining
If you wish to post on unlimited OT subjects goto: aol://5863:126/rec.crafts.metalworking or go thru Google.com to reach it if you have trouble.
http://www.metalworking.com/news_servers.html
http://groups.yahoo.com/group/jobshophomeshop I consider this to be a sister site to the CCED group, as many of the same members are there, for OT subjects, that are not allowed on the CCED list.
NOTICE: ALL POSTINGS TO THIS GROUP BECOME PUBLIC DOMAIN BY POSTING THEM. DON'T POST IF YOU CAN NOT ACCEPT THIS.....NO EXCEPTIONS........
bill
List Mom
List Owner
Yahoo! Groups Links
---------------------------------
Do you Yahoo!?
Y! Messenger - Communicate in real time. Download now.
[Non-text portions of this message have been removed]
Discussion Thread
feck123
2004-09-23 22:22:39 UTC
nema 34 motors on BP series 1 conversion
Stephen Wille Padnos
2004-09-23 23:33:50 UTC
Re: [CAD_CAM_EDM_DRO] nema 34 motors on BP series 1 conversion
R Rogers
2004-09-24 07:03:52 UTC
Re: [CAD_CAM_EDM_DRO] nema 34 motors on BP series 1 conversion
vavaroutsos
2004-09-24 08:58:05 UTC
Re: nema 34 motors on BP series 1 conversion
jlsmith269
2004-09-24 09:03:13 UTC
Re: nema 34 motors on BP series 1 conversion
Jon Elson
2004-09-24 09:22:04 UTC
Re: [CAD_CAM_EDM_DRO] nema 34 motors on BP series 1 conversion
Jon Elson
2004-09-24 09:29:02 UTC
Re: [CAD_CAM_EDM_DRO] nema 34 motors on BP series 1 conversion
R Rogers
2004-09-24 09:34:53 UTC
Re: [CAD_CAM_EDM_DRO] Re: nema 34 motors on BP series 1 conversion
R Rogers
2004-09-24 10:48:44 UTC
Re: [CAD_CAM_EDM_DRO] nema 34 motors on BP series 1 conversion
Stephen Wille Padnos
2004-09-24 11:01:55 UTC
Re: [CAD_CAM_EDM_DRO] nema 34 motors on BP series 1 conversion
R Rogers
2004-09-24 11:33:37 UTC
Re: [CAD_CAM_EDM_DRO] nema 34 motors on BP series 1 conversion
R Rogers
2004-09-24 11:35:42 UTC
Re: [CAD_CAM_EDM_DRO] nema 34 motors on BP series 1 conversion
Andy Wander
2004-09-24 11:39:23 UTC
RE: [CAD_CAM_EDM_DRO] nema 34 motors on BP series 1 conversion
Stephen Wille Padnos
2004-09-24 11:47:48 UTC
Re: [CAD_CAM_EDM_DRO] nema 34 motors on BP series 1 conversion
R Rogers
2004-09-24 11:52:25 UTC
RE: [CAD_CAM_EDM_DRO] nema 34 motors on BP series 1 conversion
R Rogers
2004-09-24 12:05:56 UTC
Re: [CAD_CAM_EDM_DRO] nema 34 motors on BP series 1 conversion
Andy Wander
2004-09-24 12:07:46 UTC
RE: [CAD_CAM_EDM_DRO] nema 34 motors on BP series 1 conversion
R Rogers
2004-09-24 12:42:06 UTC
RE: [CAD_CAM_EDM_DRO] nema 34 motors on BP series 1 conversion
Andy Wander
2004-09-24 12:54:04 UTC
RE: [CAD_CAM_EDM_DRO] nema 34 motors on BP series 1 conversion
Andy Wander
2004-09-24 12:57:29 UTC
RE: [CAD_CAM_EDM_DRO] nema 34 motors on BP series 1 conversion
R Rogers
2004-09-24 13:16:28 UTC
RE: [CAD_CAM_EDM_DRO] nema 34 motors on BP series 1 conversion
R Rogers
2004-09-24 13:28:26 UTC
RE: [CAD_CAM_EDM_DRO] nema 34 motors on BP series 1 conversion
Andy Wander
2004-09-24 13:30:23 UTC
RE: [CAD_CAM_EDM_DRO] nema 34 motors on BP series 1 conversion
Andy Wander
2004-09-24 13:31:25 UTC
RE: [CAD_CAM_EDM_DRO] nema 34 motors on BP series 1 conversion
Jon Elson
2004-09-24 20:31:28 UTC
Re: [CAD_CAM_EDM_DRO] nema 34 motors on BP series 1 conversion
Jon Elson
2004-09-24 20:35:17 UTC
Re: [CAD_CAM_EDM_DRO] nema 34 motors on BP series 1 conversion
Boss
2004-09-24 20:39:29 UTC
Re: [CAD_CAM_EDM_DRO] nema 34 motors on BP series 1 conversion
R Rogers
2004-09-25 07:32:14 UTC
Re: [CAD_CAM_EDM_DRO] nema 34 motors on BP series 1 conversion
Bill Vance
2005-01-24 15:58:01 UTC
Re: [CAD_CAM_EDM_DRO] nema 34 motors on BP series 1 conversionnccq