Re: Power supply transformer setup questions...Capacitors

on 2003-09-10 18:58:28 UTC
Dave,

The calculation represents the minimal acceptable capacitance for the
power supply where the ripple will be about 10% at full design load.
I'm building a 40VDC 10Amp power supply, and am using two 39000uF 50V
capacitors to lower the ripple even further. The capacitors are
relatively small 1.6" Dia X 3.5" long P10635-ND's from Digikey
costing about $14 USD each.

Extra capacitance in this application does not hurt, but after a
while ceases being cost-effective.

Tony

--- In CAD_CAM_EDM_DRO@yahoogroups.com, "turbulatordude"
<davemucha@j...> wrote:
>
> That brings up a unsettled question in my mind.
>
> What amperage is used for the capacitor sizing ?
> When one uses the equation of
> (C= (80,000 * I) / V)).
> C is the value in microfarads,
> I is the current
> and V is the voltage.
>
> If a motor is 5 volts, and 5 amps and one runs this at 25 volts and
> one amp, is the calculation on one amp and 25 volts ?
>
> If it is, I'm betting there are a LOT of WAY oversized power
supplies
> out there.
>
> if this is an empirical calculation based on actual data and using
> nameplate then that would be fine. But, it seems that IF it is
based
> on the watts calculation, then most of us probably have a way big
> power supply.
>
>
> Dave

Discussion Thread

Lloyd Leung 2003-09-10 04:28:49 UTC Power supply transformer setup questions... turbulatordude 2003-09-10 07:11:58 UTC Re: Power supply transformer setup questions... microboter 2003-09-10 07:38:44 UTC Re: Power supply transformer setup questions... Tim Goldstein 2003-09-10 08:03:11 UTC RE: [CAD_CAM_EDM_DRO] Re: Power supply transformer setup questions... Robert Campbell 2003-09-10 08:06:57 UTC Re: [CAD_CAM_EDM_DRO] Re: Power supply transformer setup questions... Tony Jeffree 2003-09-10 08:22:48 UTC Re: [CAD_CAM_EDM_DRO] Re: Power supply transformer setup questions... Alan Marconett KM6VV 2003-09-10 12:09:34 UTC Re: [CAD_CAM_EDM_DRO] Re: Power supply transformer setup questions... JanRwl@A... 2003-09-10 12:46:49 UTC Re: [CAD_CAM_EDM_DRO] Power supply transformer setup questions... Lloyd Leung 2003-09-10 14:08:21 UTC RE: Power supply transformer setup questions... Tim Goldstein 2003-09-10 14:30:23 UTC RE: [CAD_CAM_EDM_DRO] RE: Power supply transformer setup questions... turbulatordude 2003-09-10 14:30:33 UTC Re: Power supply transformer setup questions... Lloyd Leung 2003-09-10 14:47:28 UTC RE: Power supply transformer setup questions... Tony Jeffree 2003-09-10 16:19:27 UTC Re: [CAD_CAM_EDM_DRO] RE: Power supply transformer setup questions... Tony Jeffree 2003-09-10 16:25:19 UTC Re: [CAD_CAM_EDM_DRO] Re: Power supply transformer setup questions... JanRwl@A... 2003-09-10 16:58:28 UTC Re: [CAD_CAM_EDM_DRO] RE: Power supply transformer setup questions... turbulatordude 2003-09-10 18:45:13 UTC Re: Power supply transformer setup questions...Capacitors turbulatordude 2003-09-10 18:57:14 UTC Re: Power supply transformer setup questions... Antonius J.M. Groothuizen 2003-09-10 18:58:28 UTC Re: Power supply transformer setup questions...Capacitors Raymond Heckert 2003-09-10 19:05:20 UTC Re: [CAD_CAM_EDM_DRO] Re: Power supply transformer setup questions... JanRwl@A... 2003-09-10 19:13:58 UTC Re: [CAD_CAM_EDM_DRO] Re: Power supply transformer setup questions...Capacitors JanRwl@A... 2003-09-10 19:39:03 UTC Re: [CAD_CAM_EDM_DRO] Re: Power supply transformer setup questions... Lloyd Leung 2003-09-10 19:54:45 UTC RE: Re: Power supply transformer setup questions...Capacitors turbulatordude 2003-09-10 20:42:49 UTC Re: Power supply transformer setup questions...Capacitors turbulatordude 2003-09-11 08:35:06 UTC Re: Power supply transformer setup questions... OPP's