CAD CAM EDM DRO - Yahoo Group Archive

RE: [CAD_CAM_EDM_DRO] Variable Transformer

Posted by jkbrennan
on 2005-06-29 08:26:59 UTC
>Thanks for this info, jesse.
>
>Was there anything actually in the link you cited that supports the first
>statement below, that the isolation transformer reduces the available
>current, and is required by NEC for medical applications?
>
>Or is it a separate point? I couldn't find anything about available current
>reduction in there.
>
>Andy Wander
>Verrex Corporation
>
>1.1 These requirements cover isolated power systems equipment rated
>600 Vac or less, intended for installation and use in nonhazardous
>areas in health care facilities in accordance with the requirements
>in Article 517 of the National Electrical Code, NFPA 70, and in the
>Standard for Health Care Facilities, NFPA 99
>
>see for a lot more.
>http://www.iaei.org/magazine/02_f/johnston.htm
>
You need to go to the current NEC and NFPA codes.

OSHA inspectors don't protect you particularly. The OSHA regulations
put the practices and requirements of various standards organizations
into one Federal code. Prior to that "codes" were established by
Insurance associations ,UL, the CGA, and the engineering societies
and various trade associations. It was not a unified approach and
was slow to develop. There was no or little government political
involvement. These "regulations" were not universally adopted as
laws and so were hard to implement when political and economic
factors came into play. Non consumer equipment usually does not have
UL testing so it doesn't mean that much outside the home.
I was only heavily involved in the early days of OSHA implementation
and it was a help in getting past company economic concerns-- It
eliminated a lot of arguments when people didn't want to comply with
good practices because it was not the "law". In a corporate
environment even the safety people wanted to hide from it-- They
didn't want to admit they had deficiencies so wouldn't assist in
asking for money to correct the deficiencies..

There still are good conventional practices that are not codified.
We don't need all the politics. There is nothing to prevent you
from doing personal harm but that doesn't mean you can or should do
things that can expose others to harm.
jesse

Discussion Thread

v_bps 2005-06-28 13:50:55 UTC Variable Transformer JanRwl@A... 2005-06-28 14:04:55 UTC Re: [CAD_CAM_EDM_DRO] Variable Transformer Michael Larson 2005-06-28 14:07:44 UTC Re: [CAD_CAM_EDM_DRO] Variable Transformer Bengt Sjölund 2005-06-28 14:09:54 UTC Re: Variable Transformer Alan Marconett 2005-06-28 14:26:33 UTC RE: [CAD_CAM_EDM_DRO] Variable Transformer v_bps 2005-06-28 14:28:43 UTC Re: Variable Transformer Tony Jeffree 2005-06-28 14:30:03 UTC Re: [CAD_CAM_EDM_DRO] Variable Transformer Dave Fisher 2005-06-28 14:34:13 UTC RE: [CAD_CAM_EDM_DRO] Variable Transformer Andy Wander 2005-06-28 14:59:58 UTC RE: [CAD_CAM_EDM_DRO] Variable Transformer Carl Mikkelsen 2005-06-28 15:48:30 UTC RE: [CAD_CAM_EDM_DRO] Variable Transformer Tony Jeffree 2005-06-28 15:50:43 UTC RE: [CAD_CAM_EDM_DRO] Variable Transformer Andy Wander 2005-06-28 17:15:12 UTC RE: [CAD_CAM_EDM_DRO] Variable Transformer Michael Larson 2005-06-28 17:39:41 UTC Re: [CAD_CAM_EDM_DRO] Variable Transformer Andy Wander 2005-06-28 18:26:25 UTC RE: [CAD_CAM_EDM_DRO] Variable Transformer bank haam 2005-06-28 18:33:32 UTC RE: [CAD_CAM_EDM_DRO] Variable Transformer JanRwl@A... 2005-06-28 21:52:00 UTC Re: [CAD_CAM_EDM_DRO] Variable Transformer Tom Harrison 2005-06-28 23:24:46 UTC Re: [CAD_CAM_EDM_DRO] Variable Transformer caedave 2005-06-29 01:32:21 UTC Re: [CAD_CAM_EDM_DRO] Variable Transformer Andy Wander 2005-06-29 04:19:15 UTC RE: [CAD_CAM_EDM_DRO] Variable Transformer Andy Wander 2005-06-29 04:22:38 UTC RE: [CAD_CAM_EDM_DRO] Variable Transformer Andy Wander 2005-06-29 04:27:10 UTC RE: [CAD_CAM_EDM_DRO] Variable Transformer Tony Jeffree 2005-06-29 05:08:03 UTC RE: [CAD_CAM_EDM_DRO] Variable Transformer Andy Wander 2005-06-29 05:14:13 UTC RE: [CAD_CAM_EDM_DRO] Variable Transformer John Meissner 2005-06-29 05:18:33 UTC Re: Variable Transformer turbulatordude 2005-06-29 05:30:01 UTC Re: Variable Transformer Andy Wander 2005-06-29 05:30:44 UTC RE: [CAD_CAM_EDM_DRO] Re: Variable Transformer Andy Wander 2005-06-29 05:33:37 UTC RE: [CAD_CAM_EDM_DRO] Re: Variable Transformer turbulatordude 2005-06-29 05:49:43 UTC Re: Variable Transformer Andy Wander 2005-06-29 05:55:45 UTC RE: [CAD_CAM_EDM_DRO] Re: Variable Transformer jkbrennan 2005-06-29 06:41:20 UTC RE: [CAD_CAM_EDM_DRO] Variable Transformer Andy Wander 2005-06-29 06:54:12 UTC RE: [CAD_CAM_EDM_DRO] Variable Transformer Hugh Prescott 2005-06-29 07:36:58 UTC Re: [CAD_CAM_EDM_DRO] Re: Variable Transformer Andy Wander 2005-06-29 07:54:48 UTC RE: [CAD_CAM_EDM_DRO] Re: Variable Transformer jkbrennan 2005-06-29 08:26:59 UTC RE: [CAD_CAM_EDM_DRO] Variable Transformer Vince Negrete 2005-06-29 08:49:16 UTC Re: [CAD_CAM_EDM_DRO] Re: Variable Transformer Alan Marconett 2005-06-29 09:13:47 UTC RE: [CAD_CAM_EDM_DRO] Variable Transformer Andy Wander 2005-06-29 09:26:57 UTC RE: [CAD_CAM_EDM_DRO] Variable Transformer Andy Wander 2005-06-29 09:29:25 UTC RE: [CAD_CAM_EDM_DRO] Variable Transformer Alan Marconett 2005-06-29 10:02:35 UTC [Spam] RE: [CAD_CAM_EDM_DRO] Variable Transformer Jack 2005-06-29 10:10:34 UTC Re: [Spam] RE: [CAD_CAM_EDM_DRO] Variable Transformer Jon Elson 2005-06-29 10:36:14 UTC Re: [CAD_CAM_EDM_DRO] Variable Transformer Andy Wander 2005-06-29 10:47:32 UTC RE: [CAD_CAM_EDM_DRO] Variable Transformer George Taylor, IV 2005-06-29 10:55:13 UTC Re: [CAD_CAM_EDM_DRO] Variable Transformer Stephen Wille Padnos 2005-06-29 12:05:49 UTC Re: [Spam] RE: [CAD_CAM_EDM_DRO] Variable Transformer Roy J. Tellason 2005-06-29 13:20:12 UTC Re: [CAD_CAM_EDM_DRO] Variable Transformer Jon Elson 2005-06-29 18:36:31 UTC Re: [CAD_CAM_EDM_DRO] Variable Transformer Jon Elson 2005-06-29 18:37:32 UTC Re: [CAD_CAM_EDM_DRO] Variable Transformer Andy Wander 2005-06-29 19:36:51 UTC RE: [CAD_CAM_EDM_DRO] Variable Transformer Raymond Heckert 2005-06-29 20:01:38 UTC Re: [CAD_CAM_EDM_DRO] Variable Transformer Andy Wander 2005-06-30 04:47:46 UTC RE: [CAD_CAM_EDM_DRO] Variable Transformer Doug M 2005-06-30 08:49:28 UTC Re: [CAD_CAM_EDM_DRO] Variable Transformer Andy Wander 2005-06-30 08:54:30 UTC RE: [CAD_CAM_EDM_DRO] Variable Transformer JanRwl@A... 2005-06-30 13:07:17 UTC Re: [CAD_CAM_EDM_DRO] Variable Transformer Hugh Prescott 2005-06-30 13:32:23 UTC Re: [CAD_CAM_EDM_DRO] Variable Transformer Raymond Heckert 2005-07-01 20:08:45 UTC Re: [CAD_CAM_EDM_DRO] Variable Transformer Andy Wander 2005-07-02 06:27:31 UTC RE: [CAD_CAM_EDM_DRO] Variable Transformer Raymond Heckert 2005-07-03 16:52:35 UTC Re: [CAD_CAM_EDM_DRO] Variable Transformer