Definition, definition, definition, but I see what you mean.
By definition your estop switches are closed loop in that they
detect a state/condition and take an action based on that.
This does not mean that the machine/devise as a whole
works in a closed loop. That only comes with a fully
integrated closed loops system, where every error
is detected and corrected on the fly.
Dave M.
By definition your estop switches are closed loop in that they
detect a state/condition and take an action based on that.
This does not mean that the machine/devise as a whole
works in a closed loop. That only comes with a fully
integrated closed loops system, where every error
is detected and corrected on the fly.
Dave M.
----- Original Message -----
From: "Stephen Wille Padnos" <spadnos@...>
> True.
>
> And by definition, this is not closed loop for Mach3. Closed loop
> control implies that the position error is used in trajectory
> calculations. That's not what was described. The described
> functionality is more like a traveling soft limit switch - it'll trip if
> the actual position is outside a set range from the commanded position.
>
> It's open loop with an error bar.
>
> - Steve
--
No virus found in this outgoing message.
Checked by AVG Anti-Virus.
Version: 7.0.338 / Virus Database: 267.9.4/57 - Release Date: 22/07/2005
Discussion Thread
R Rogers
2005-07-22 13:42:25 UTC
Announcement: Mach3 is now closed loop!
Babar
2005-07-22 20:48:50 UTC
Re: [CAD_CAM_EDM_DRO] Announcement: Mach3 is now closed loop!
Jon Elson
2005-07-22 22:58:01 UTC
Re: [CAD_CAM_EDM_DRO] Announcement: Mach3 is now closed loop!
R Rogers
2005-07-23 05:19:17 UTC
Re: [CAD_CAM_EDM_DRO] Announcement: Mach3 is now closed loop!
Paul
2005-07-23 05:47:21 UTC
Re: [CAD_CAM_EDM_DRO] Announcement: Mach3 is now closed loop!
Dan Mauch
2005-07-23 06:34:41 UTC
Re: [CAD_CAM_EDM_DRO] Announcement: Mach3 is now closed loop!
Jon Elson
2005-07-23 15:35:57 UTC
Re: [CAD_CAM_EDM_DRO] Announcement: Mach3 is now closed loop!
caedave
2005-07-24 02:36:46 UTC
Re: [CAD_CAM_EDM_DRO] Announcement: Mach3 is now closed loop!
Mariss Freimanis
2005-07-24 13:13:23 UTC
Re: Announcement: Mach3 is now closed loop!
Stephen Wille Padnos
2005-07-25 19:28:41 UTC
Re: [CAD_CAM_EDM_DRO] Announcement: Mach3 is now closed loop!
R Rogers
2005-07-25 20:34:02 UTC
Re: [CAD_CAM_EDM_DRO] Announcement: Mach3 is now closed loop!
John Delaney
2005-07-25 21:16:21 UTC
'Nother closed loop anecdote
caedave
2005-07-26 02:20:14 UTC
Re: [CAD_CAM_EDM_DRO] Announcement: Mach3 is now closed loop!
Thom Carr
2005-07-26 05:24:11 UTC
Re: [CAD_CAM_EDM_DRO] Announcement: Mach3 is now closed loop!
Alex Holden
2005-07-26 06:19:05 UTC
Re: [CAD_CAM_EDM_DRO] Announcement: Mach3 is now closed loop!
Alan Marconett
2005-07-26 08:25:06 UTC
[Spam] RE: [CAD_CAM_EDM_DRO] Announcement: Mach3 is now closed loop!
Jon Elson
2005-07-26 09:02:00 UTC
Re: [CAD_CAM_EDM_DRO] Announcement: Mach3 is now closed loop!
caedave
2005-07-26 09:45:31 UTC
Re: [CAD_CAM_EDM_DRO] Announcement: Mach3 is now closed loop!
Mariss Freimanis
2005-07-26 09:48:53 UTC
Re: Announcement: Mach3 is now closed loop!
David A. Frantz
2005-07-26 10:13:13 UTC
Re: [CAD_CAM_EDM_DRO] Announcement: Mach3 is now closed loop!