> Now I'm confused.When a pin goes high it is at +5V (well it should, but some systems
> I thought it was either ground from the parallel
> port, or +5V from the compueter power supply?
don't make the full swing), but there is not enough current from the pin
for more than one LED. G201s are wired to use a common +5V and switch on
the LED in the opto when the pin goes low and current flows to it.
G210's can be set up to use the current from the pin with a common
ground.
Tim
[Denver, CO]
Beat the Sherline Oct 1 price increase. Order Now!
New Sherline Prices at http://www.ktmarketing.com/SherlineIncrease.htm
Sherline & Taig products at Deep Discount
Mach1 & DeskCNC with credit card ordering
www.KTMarketing.com/Sherline
e-mail me at Timg @ KTMarketing.com for items not yet listed
Discussion Thread
Weyland
2003-09-12 18:15:35 UTC
Clarifications needed -
Tim Goldstein
2003-09-12 18:34:54 UTC
RE: [CAD_CAM_EDM_DRO] Clarifications needed -
washcomp
2003-09-12 18:45:04 UTC
Re: Clarifications needed -
Weyland
2003-09-12 19:45:08 UTC
Re: [CAD_CAM_EDM_DRO] Clarifications needed -
Tim Goldstein
2003-09-12 19:55:48 UTC
RE: [CAD_CAM_EDM_DRO] Clarifications needed -
Weyland
2003-09-12 19:56:45 UTC
Re: [CAD_CAM_EDM_DRO] Re: Clarifications needed -
Weyland
2003-09-12 20:09:51 UTC
Re: [CAD_CAM_EDM_DRO] Clarifications needed -
Tim Goldstein
2003-09-12 20:40:20 UTC
RE: [CAD_CAM_EDM_DRO] Re: Clarifications needed -
Jon Elson
2003-09-12 20:42:47 UTC
Re: [CAD_CAM_EDM_DRO] Clarifications needed -
washcomp
2003-09-12 20:59:18 UTC
Re: Clarifications needed -
Jon Elson
2003-09-12 21:16:10 UTC
Re: [CAD_CAM_EDM_DRO] Clarifications needed -
Jon Elson
2003-09-12 21:27:04 UTC
Re: [CAD_CAM_EDM_DRO] Re: Clarifications needed -
Harvey White
2003-09-12 21:48:41 UTC
Re: [CAD_CAM_EDM_DRO] Re: Clarifications needed -
turbulatordude
2003-09-13 06:12:48 UTC
Re: Clarifications needed - 5 volts
Graham Stabler
2003-09-13 09:01:17 UTC
Re: Clarifications needed - 5 volts
Harvey White
2003-09-13 09:37:11 UTC
Re: [CAD_CAM_EDM_DRO] Re: Clarifications needed - 5 volts
Keith Bowers
2003-09-13 12:48:21 UTC
Re: [CAD_CAM_EDM_DRO] Clarifications needed -
Alan Marconett KM6VV
2003-09-13 13:09:37 UTC
Re: [CAD_CAM_EDM_DRO] Re: Clarifications needed - 5 volts
Mariss Freimanis
2003-09-13 14:21:11 UTC
Re: Clarifications needed - 5 volts
Harvey White
2003-09-13 14:29:22 UTC
Re: [CAD_CAM_EDM_DRO] Re: Clarifications needed - 5 volts
Weyland
2003-09-13 19:04:38 UTC
Re: [CAD_CAM_EDM_DRO] Re: Clarifications needed -
Weyland
2003-09-13 19:32:30 UTC
Re: [CAD_CAM_EDM_DRO] Clarifications needed -
Weyland
2003-09-13 19:33:57 UTC
Re: [CAD_CAM_EDM_DRO] Re: Clarifications needed -
Weyland
2003-09-13 19:40:28 UTC
Re: [CAD_CAM_EDM_DRO] Re: Clarifications needed -
Weyland
2003-09-13 19:46:04 UTC
Re: [CAD_CAM_EDM_DRO] Re: Clarifications needed - 5 volts
Tim Goldstein
2003-09-13 21:16:52 UTC
RE: [CAD_CAM_EDM_DRO] Re: Clarifications needed -
Weyland
2003-09-13 21:36:32 UTC
Re: [CAD_CAM_EDM_DRO] Re: Clarifications needed -
Antonius J.M. Groothuizen
2003-09-13 22:24:37 UTC
Re: Clarifications needed -
amoss_70
2003-09-13 23:37:20 UTC
Re: Clarifications needed -
Graham Stabler
2003-09-14 12:13:24 UTC
Re: Clarifications needed - 5 volts