Re: [CAD_CAM_EDM_DRO] Re: Clarifications needed - 5 volts

Posted by Weyland
on 2003-09-13 19:46:04 UTC
On Saturday 13 September 2003 09:12 am, turbulatordude spake:

> reading the posts, it seems that simplicity is desired.

Always.

> the 5 volts are easy to pick off from inside of the computer on any
> power connection.
> If you have a spare wye connecter you can cut one of the ends off,
> pluge it into one of the spare power connectors, and snake the wire
> out of the case and into your driver enclosure.

I did something very similar today.
Since I'v built the controller enclosure to house _EVERYTHING_ (meaning motor
power supply, Geckos, Computer parts, breakout board, Computer power supply,
etc...), I used a spare molex connector with wires and crimped ends on all
four wires (red, black, black, yellow).

Then I used one of the Radio Shack barrier
strips (with a handy four positions) to connect to it.
Plugging that in to one of the moles connectors from the computer power
supply, I not only get my +5V now, but I also have a handy place to get the
12V for the 3 CPU fans and heatsinks on the back of the Geckos.

Thanks,

Weyland

Discussion Thread

Weyland 2003-09-12 18:15:35 UTC Clarifications needed - Tim Goldstein 2003-09-12 18:34:54 UTC RE: [CAD_CAM_EDM_DRO] Clarifications needed - washcomp 2003-09-12 18:45:04 UTC Re: Clarifications needed - Weyland 2003-09-12 19:45:08 UTC Re: [CAD_CAM_EDM_DRO] Clarifications needed - Tim Goldstein 2003-09-12 19:55:48 UTC RE: [CAD_CAM_EDM_DRO] Clarifications needed - Weyland 2003-09-12 19:56:45 UTC Re: [CAD_CAM_EDM_DRO] Re: Clarifications needed - Weyland 2003-09-12 20:09:51 UTC Re: [CAD_CAM_EDM_DRO] Clarifications needed - Tim Goldstein 2003-09-12 20:40:20 UTC RE: [CAD_CAM_EDM_DRO] Re: Clarifications needed - Jon Elson 2003-09-12 20:42:47 UTC Re: [CAD_CAM_EDM_DRO] Clarifications needed - washcomp 2003-09-12 20:59:18 UTC Re: Clarifications needed - Jon Elson 2003-09-12 21:16:10 UTC Re: [CAD_CAM_EDM_DRO] Clarifications needed - Jon Elson 2003-09-12 21:27:04 UTC Re: [CAD_CAM_EDM_DRO] Re: Clarifications needed - Harvey White 2003-09-12 21:48:41 UTC Re: [CAD_CAM_EDM_DRO] Re: Clarifications needed - turbulatordude 2003-09-13 06:12:48 UTC Re: Clarifications needed - 5 volts Graham Stabler 2003-09-13 09:01:17 UTC Re: Clarifications needed - 5 volts Harvey White 2003-09-13 09:37:11 UTC Re: [CAD_CAM_EDM_DRO] Re: Clarifications needed - 5 volts Keith Bowers 2003-09-13 12:48:21 UTC Re: [CAD_CAM_EDM_DRO] Clarifications needed - Alan Marconett KM6VV 2003-09-13 13:09:37 UTC Re: [CAD_CAM_EDM_DRO] Re: Clarifications needed - 5 volts Mariss Freimanis 2003-09-13 14:21:11 UTC Re: Clarifications needed - 5 volts Harvey White 2003-09-13 14:29:22 UTC Re: [CAD_CAM_EDM_DRO] Re: Clarifications needed - 5 volts Weyland 2003-09-13 19:04:38 UTC Re: [CAD_CAM_EDM_DRO] Re: Clarifications needed - Weyland 2003-09-13 19:32:30 UTC Re: [CAD_CAM_EDM_DRO] Clarifications needed - Weyland 2003-09-13 19:33:57 UTC Re: [CAD_CAM_EDM_DRO] Re: Clarifications needed - Weyland 2003-09-13 19:40:28 UTC Re: [CAD_CAM_EDM_DRO] Re: Clarifications needed - Weyland 2003-09-13 19:46:04 UTC Re: [CAD_CAM_EDM_DRO] Re: Clarifications needed - 5 volts Tim Goldstein 2003-09-13 21:16:52 UTC RE: [CAD_CAM_EDM_DRO] Re: Clarifications needed - Weyland 2003-09-13 21:36:32 UTC Re: [CAD_CAM_EDM_DRO] Re: Clarifications needed - Antonius J.M. Groothuizen 2003-09-13 22:24:37 UTC Re: Clarifications needed - amoss_70 2003-09-13 23:37:20 UTC Re: Clarifications needed - Graham Stabler 2003-09-14 12:13:24 UTC Re: Clarifications needed - 5 volts