Re: [CAD_CAM_EDM_DRO] Clarifications needed -
Posted by
Keith Bowers
on 2003-09-13 12:48:21 UTC
On Friday 12 September 2003 10:45 pm, Weyland wrote:
Don't bet on the UPS switching perfictly cleanly. I scrapped a rather
expensive name brand UPS when I found that under certain conditions it
produced a HUDGE switchover spike; enough to cook surge protectors now and
then. YMMV
--
Keith Bowers - Thomasville, NC
> On Friday 12 September 2003 09:34 pm, Tim Goldstein spake:<snip>
> > > My concern is over the 80 VDC limit for the
> > > Geckos. (G210s marked with "90IFX" on the covers.)
> >
> > What happens when your power company lets the voltage float high?
> > According to Mariss (and he should know) the number 1 cause of blown
> > Geckos by a large margin is over voltage.
>
> mmmHmmmm... I hadn't thought of that. Thanks.
> But wouldn't the UPS (if used here) help there, as well?
> (Assuming that I used the right one, that had
> over-voltage protection as well as under-voltage)
> <...like a SmartUPS...>
Don't bet on the UPS switching perfictly cleanly. I scrapped a rather
expensive name brand UPS when I found that under certain conditions it
produced a HUDGE switchover spike; enough to cook surge protectors now and
then. YMMV
--
Keith Bowers - Thomasville, NC
Discussion Thread
Weyland
2003-09-12 18:15:35 UTC
Clarifications needed -
Tim Goldstein
2003-09-12 18:34:54 UTC
RE: [CAD_CAM_EDM_DRO] Clarifications needed -
washcomp
2003-09-12 18:45:04 UTC
Re: Clarifications needed -
Weyland
2003-09-12 19:45:08 UTC
Re: [CAD_CAM_EDM_DRO] Clarifications needed -
Tim Goldstein
2003-09-12 19:55:48 UTC
RE: [CAD_CAM_EDM_DRO] Clarifications needed -
Weyland
2003-09-12 19:56:45 UTC
Re: [CAD_CAM_EDM_DRO] Re: Clarifications needed -
Weyland
2003-09-12 20:09:51 UTC
Re: [CAD_CAM_EDM_DRO] Clarifications needed -
Tim Goldstein
2003-09-12 20:40:20 UTC
RE: [CAD_CAM_EDM_DRO] Re: Clarifications needed -
Jon Elson
2003-09-12 20:42:47 UTC
Re: [CAD_CAM_EDM_DRO] Clarifications needed -
washcomp
2003-09-12 20:59:18 UTC
Re: Clarifications needed -
Jon Elson
2003-09-12 21:16:10 UTC
Re: [CAD_CAM_EDM_DRO] Clarifications needed -
Jon Elson
2003-09-12 21:27:04 UTC
Re: [CAD_CAM_EDM_DRO] Re: Clarifications needed -
Harvey White
2003-09-12 21:48:41 UTC
Re: [CAD_CAM_EDM_DRO] Re: Clarifications needed -
turbulatordude
2003-09-13 06:12:48 UTC
Re: Clarifications needed - 5 volts
Graham Stabler
2003-09-13 09:01:17 UTC
Re: Clarifications needed - 5 volts
Harvey White
2003-09-13 09:37:11 UTC
Re: [CAD_CAM_EDM_DRO] Re: Clarifications needed - 5 volts
Keith Bowers
2003-09-13 12:48:21 UTC
Re: [CAD_CAM_EDM_DRO] Clarifications needed -
Alan Marconett KM6VV
2003-09-13 13:09:37 UTC
Re: [CAD_CAM_EDM_DRO] Re: Clarifications needed - 5 volts
Mariss Freimanis
2003-09-13 14:21:11 UTC
Re: Clarifications needed - 5 volts
Harvey White
2003-09-13 14:29:22 UTC
Re: [CAD_CAM_EDM_DRO] Re: Clarifications needed - 5 volts
Weyland
2003-09-13 19:04:38 UTC
Re: [CAD_CAM_EDM_DRO] Re: Clarifications needed -
Weyland
2003-09-13 19:32:30 UTC
Re: [CAD_CAM_EDM_DRO] Clarifications needed -
Weyland
2003-09-13 19:33:57 UTC
Re: [CAD_CAM_EDM_DRO] Re: Clarifications needed -
Weyland
2003-09-13 19:40:28 UTC
Re: [CAD_CAM_EDM_DRO] Re: Clarifications needed -
Weyland
2003-09-13 19:46:04 UTC
Re: [CAD_CAM_EDM_DRO] Re: Clarifications needed - 5 volts
Tim Goldstein
2003-09-13 21:16:52 UTC
RE: [CAD_CAM_EDM_DRO] Re: Clarifications needed -
Weyland
2003-09-13 21:36:32 UTC
Re: [CAD_CAM_EDM_DRO] Re: Clarifications needed -
Antonius J.M. Groothuizen
2003-09-13 22:24:37 UTC
Re: Clarifications needed -
amoss_70
2003-09-13 23:37:20 UTC
Re: Clarifications needed -
Graham Stabler
2003-09-14 12:13:24 UTC
Re: Clarifications needed - 5 volts