RE: [CAD_CAM_EDM_DRO] Re: Clarifications needed -
Posted by
Tim Goldstein
on 2003-09-13 21:16:52 UTC
> Would you and others recommend I have it lower?Each motor and drive will see the full voltage. It is not reduced by
>
> I'm not sure at this point if it makes a difference, but all
> three motors ( with a fourth later) run off of this voltage.
> I'm guessing, but it seems possible to have all three axis' drawing
> off of the output voltage at once, making each get 1/3
> available... Or am I thinking of this incorrectly?
connecting more (unless you did it in series and that would be a bad
thing). I would recommend you aim for about 60 - 65 VDC. That give you a
good amount of headroom and will still give you great performance.
Tim
[Denver, CO]
Beat the Sherline Oct 1 price increase. Order Now!
New Sherline Prices at http://www.ktmarketing.com/SherlineIncrease.htm
Sherline & Taig products at Deep Discount
Mach1 & DeskCNC with credit card ordering
www.KTMarketing.com/Sherline
e-mail me at Timg @ KTMarketing.com for items not yet listed
Discussion Thread
Weyland
2003-09-12 18:15:35 UTC
Clarifications needed -
Tim Goldstein
2003-09-12 18:34:54 UTC
RE: [CAD_CAM_EDM_DRO] Clarifications needed -
washcomp
2003-09-12 18:45:04 UTC
Re: Clarifications needed -
Weyland
2003-09-12 19:45:08 UTC
Re: [CAD_CAM_EDM_DRO] Clarifications needed -
Tim Goldstein
2003-09-12 19:55:48 UTC
RE: [CAD_CAM_EDM_DRO] Clarifications needed -
Weyland
2003-09-12 19:56:45 UTC
Re: [CAD_CAM_EDM_DRO] Re: Clarifications needed -
Weyland
2003-09-12 20:09:51 UTC
Re: [CAD_CAM_EDM_DRO] Clarifications needed -
Tim Goldstein
2003-09-12 20:40:20 UTC
RE: [CAD_CAM_EDM_DRO] Re: Clarifications needed -
Jon Elson
2003-09-12 20:42:47 UTC
Re: [CAD_CAM_EDM_DRO] Clarifications needed -
washcomp
2003-09-12 20:59:18 UTC
Re: Clarifications needed -
Jon Elson
2003-09-12 21:16:10 UTC
Re: [CAD_CAM_EDM_DRO] Clarifications needed -
Jon Elson
2003-09-12 21:27:04 UTC
Re: [CAD_CAM_EDM_DRO] Re: Clarifications needed -
Harvey White
2003-09-12 21:48:41 UTC
Re: [CAD_CAM_EDM_DRO] Re: Clarifications needed -
turbulatordude
2003-09-13 06:12:48 UTC
Re: Clarifications needed - 5 volts
Graham Stabler
2003-09-13 09:01:17 UTC
Re: Clarifications needed - 5 volts
Harvey White
2003-09-13 09:37:11 UTC
Re: [CAD_CAM_EDM_DRO] Re: Clarifications needed - 5 volts
Keith Bowers
2003-09-13 12:48:21 UTC
Re: [CAD_CAM_EDM_DRO] Clarifications needed -
Alan Marconett KM6VV
2003-09-13 13:09:37 UTC
Re: [CAD_CAM_EDM_DRO] Re: Clarifications needed - 5 volts
Mariss Freimanis
2003-09-13 14:21:11 UTC
Re: Clarifications needed - 5 volts
Harvey White
2003-09-13 14:29:22 UTC
Re: [CAD_CAM_EDM_DRO] Re: Clarifications needed - 5 volts
Weyland
2003-09-13 19:04:38 UTC
Re: [CAD_CAM_EDM_DRO] Re: Clarifications needed -
Weyland
2003-09-13 19:32:30 UTC
Re: [CAD_CAM_EDM_DRO] Clarifications needed -
Weyland
2003-09-13 19:33:57 UTC
Re: [CAD_CAM_EDM_DRO] Re: Clarifications needed -
Weyland
2003-09-13 19:40:28 UTC
Re: [CAD_CAM_EDM_DRO] Re: Clarifications needed -
Weyland
2003-09-13 19:46:04 UTC
Re: [CAD_CAM_EDM_DRO] Re: Clarifications needed - 5 volts
Tim Goldstein
2003-09-13 21:16:52 UTC
RE: [CAD_CAM_EDM_DRO] Re: Clarifications needed -
Weyland
2003-09-13 21:36:32 UTC
Re: [CAD_CAM_EDM_DRO] Re: Clarifications needed -
Antonius J.M. Groothuizen
2003-09-13 22:24:37 UTC
Re: Clarifications needed -
amoss_70
2003-09-13 23:37:20 UTC
Re: Clarifications needed -
Graham Stabler
2003-09-14 12:13:24 UTC
Re: Clarifications needed - 5 volts