RE: [CAD_CAM_EDM_DRO] Re: repeatable vs accurate switch
Posted by
Mark Thompson
on 2003-11-05 09:20:26 UTC
You can use a magnetic proxmity sensor switch.
These switch/sensors will provide accurate detection.
They are not cheap, but if you need the accuracy.
Good Luck
Mark
-----Original Message-----
From: Torsten [mailto:torsten@...]
Sent: Wednesday, November 05, 2003 1:32 AM
To: CAD_CAM_EDM_DRO@yahoogroups.com
Subject: [CAD_CAM_EDM_DRO] Re: repeatable vs accurate switch
These switch/sensors will provide accurate detection.
They are not cheap, but if you need the accuracy.
Good Luck
Mark
-----Original Message-----
From: Torsten [mailto:torsten@...]
Sent: Wednesday, November 05, 2003 1:32 AM
To: CAD_CAM_EDM_DRO@yahoogroups.com
Subject: [CAD_CAM_EDM_DRO] Re: repeatable vs accurate switch
--- In CAD_CAM_EDM_DRO@yahoogroups.com, Don Rogers <Don@C...> wrote:
> I am working on a machine design that needs a signal that is
repeatable to
> a very tight tolerance. I don't care if it trips at 0.250" or at
> 0.000250", as long as it is the same each time. My thoughts now
are
> focusing on optical sensors. First is just a plane flag through an
optical
> coupler, and the second is a mechanical amplified version, IE a 10X
gear
> driven optical aperture.
>
> Any pitfalls or ideas that come to mind??
>
> Thanks Don
Every switch should be repeatable unless the switch is broke.
Accurate is largely defined as very fast switching in motion
control.
A table moving at a fast velocity is recieving a move pulse
in microsecond intervals. The switch will have to send the
signal also at a very fast speed to let the controller know
that it has triggered.
Keep in mind that if the object of the switch is to stop motion
that a mass moving can not be stopped instantly but has to allow
for some distance to decelerate.
Find a suitable switch with a fast responds time.
Good Luck
Addresses:
FAQ: http://www.ktmarketing.com/faq.html
FILES: http://groups.yahoo.com/group/CAD_CAM_EDM_DRO/files/
Post Messages: CAD_CAM_EDM_DRO@yahoogroups.com
Subscribe: CAD_CAM_EDM_DRO-subscribe@yahoogroups.com
Unsubscribe: CAD_CAM_EDM_DRO-unsubscribe@yahoogroups.com
List owner: CAD_CAM_EDM_DRO-owner@yahoogroups.com, wanliker@..., timg@...
Moderator: pentam@... indigo_red@... [Moderators]
URL to this group: http://groups.yahoo.com/group/CAD_CAM_EDM_DRO
OFF Topic POSTS: General Machining
If you wish to post on unlimited OT subjects goto: aol://5863:126/rec.crafts.metalworking or go thru Google.com to reach it if you have trouble.
http://www.metalworking.com/news_servers.html
http://groups.yahoo.com/group/jobshophomeshop I consider this to be a sister site to the CCED group, as many of the same members are there, for OT subjects, that are not allowed on the CCED list.
NOTICE: ALL POSTINGS TO THIS GROUP BECOME PUBLIC DOMAIN BY POSTING THEM. DON'T POST IF YOU CAN NOT ACCEPT THIS.....NO EXCEPTIONS........
bill
List Mom
List Owner
Your use of Yahoo! Groups is subject to http://docs.yahoo.com/info/terms/
Discussion Thread
Don Rogers
2003-11-04 21:22:28 UTC
repeatable vs accurate switch
John Haddy
2003-11-04 21:27:56 UTC
RE: [CAD_CAM_EDM_DRO] repeatable vs accurate switch
Doug Fortune
2003-11-04 21:58:57 UTC
Re: [CAD_CAM_EDM_DRO] repeatable vs accurate switch
Mariss Freimanis
2003-11-04 22:11:41 UTC
Re: repeatable vs accurate switch
Marvin Frankel
2003-11-05 01:06:04 UTC
Re: [CAD_CAM_EDM_DRO] repeatable vs accurate switch
Torsten
2003-11-05 01:32:10 UTC
Re: repeatable vs accurate switch
Mark Thompson
2003-11-05 09:20:26 UTC
RE: [CAD_CAM_EDM_DRO] Re: repeatable vs accurate switch
David A. Frantz
2003-11-05 19:31:07 UTC
Re: [CAD_CAM_EDM_DRO] repeatable vs accurate switch
JanRwl@A...
2003-11-05 19:48:50 UTC
Re: [CAD_CAM_EDM_DRO] repeatable vs accurate switch
Mariss Freimanis
2003-11-05 20:29:04 UTC
Re: repeatable vs accurate switch
George Richardson
2003-11-06 07:41:24 UTC
Re: repeatable vs accurate switch
Bob Simon
2003-11-06 07:53:02 UTC
Re: [CAD_CAM_EDM_DRO] Re: repeatable vs accurate switch
Don Rogers
2003-11-06 08:38:38 UTC
Re: repeatable vs accurate switch
Don Rogers
2003-11-06 08:42:46 UTC
Re: repeatable vs accurate switch
Don Rogers
2003-11-06 09:25:59 UTC
Re: repeatable vs accurate switch
Kim Lux
2003-11-06 12:22:01 UTC
Automatic or easier tool changes for R8 mills ?
Mike Gann
2003-11-06 12:53:04 UTC
RE: [CAD_CAM_EDM_DRO] Automatic or easier tool changes for R8 mills ?
Kim Lux
2003-11-06 13:10:51 UTC
RE: [CAD_CAM_EDM_DRO] Automatic or easier tool changes for R8 mills ?
Mike Gann
2003-11-06 13:21:45 UTC
RE: [CAD_CAM_EDM_DRO] Automatic or easier tool changes for R8mills ?
Mike Gann
2003-11-06 13:34:24 UTC
RE: [CAD_CAM_EDM_DRO] Automatic or easier tool changes for R8mills ?
Carlos Guillermo
2003-11-06 13:45:43 UTC
RE: [CAD_CAM_EDM_DRO] Automatic or easier tool changes for R8mills ?
Kim Lux
2003-11-06 15:15:41 UTC
RE: [CAD_CAM_EDM_DRO] Automatic or easier tool changes for R8mills ?
Kim Lux
2003-11-06 15:18:23 UTC
RE: [CAD_CAM_EDM_DRO] Automatic or easier tool changes for R8mills ?
tjstraz
2003-11-06 16:23:25 UTC
Re: Automatic or easier tool changes for R8 mills ?
David A. Frantz
2003-11-06 17:16:36 UTC
Re: [CAD_CAM_EDM_DRO] Re: repeatable vs accurate switch
cncgrumpyguy
2003-11-06 18:53:07 UTC
Re: Automatic or easier tool changes for R8 mills ?
mmurray701
2003-11-06 19:34:53 UTC
Re: Automatic or easier tool changes for R8 mills ?
Carlos Guillermo
2003-11-06 20:48:09 UTC
RE: [CAD_CAM_EDM_DRO] Automatic or easier tool changes for R8mills?
vavaroutsos
2003-11-06 23:12:19 UTC
Re: Automatic or easier tool changes for R8 mills ?
cncgrumpyguy
2003-11-07 10:33:10 UTC
Re: Automatic or easier tool changes for R8 mills ?
mmurray701
2003-11-07 20:56:18 UTC
Re: Automatic or easier tool changes for R8 mills ?